BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

165 related articles for article (PubMed ID: 666024)

  • 1. Physical characteristics of and rates of nitrous oxide diffusion into tracheal tube cuffs.
    Bernhard WN; Yost LC; Turndorf H; Cottrell JE; Paegle RD
    Anesthesiology; 1978 Jun; 48(6):413-7. PubMed ID: 666024
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effects of nitrous oxide and oxygen on tracheal tube cuff gas volumes.
    Mehta S
    Br J Anaesth; 1981 Nov; 53(11):1227-31. PubMed ID: 7326169
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Nitrous oxide diffusion into tracheal tube cuffs: comparison of five different tracheal tube cuffs.
    Dullenkopf A; Gerber AC; Weiss M
    Acta Anaesthesiol Scand; 2004 Oct; 48(9):1180-4. PubMed ID: 15352966
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Rapid deflation of the bronchial cuff of the double-lumen tube after decreasing the concentration of inspired nitrous oxide.
    Karasawa F; Takita A; Takamatsu I; Mori T; Oshima T; Kawatani Y
    Anesth Analg; 2002 Jul; 95(1):238-42, table of contents. PubMed ID: 12088977
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Laboratory evaluation of low-pressure tracheal tube cuffs: large-volume v. low-volume.
    Kim JM; Mangold JV; Hacker DC
    Br J Anaesth; 1985 Sep; 57(9):913-8. PubMed ID: 4027107
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An assessment of a method of inflating cuffs with a nitrous oxide gas mixture to prevent an increase in intracuff pressure in five different tracheal tube designs apparatus.
    Karasawa F; Tokunaga M; Aramaki Y; Shizukuishi M; Satoh T
    Anaesthesia; 2001 Feb; 56(2):155-9. PubMed ID: 11167475
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The TaperGuard™ endotracheal tube intracuff pressure increase is less than that of the Hi-Lo™ tube during nitrous oxide exposure: a model trachea study.
    Tsuboi S; Miyashita T; Yamaguchi Y; Yamamoto Y; Sakamaki K; Goto T
    Anesth Analg; 2013 Mar; 116(3):609-12. PubMed ID: 23400983
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Tracheal tube cuff pressure. Changes during nitrous oxide anaesthesia following inflation of cuffs with air and saline.
    Patel RI; Oh TH; Chandra R; Epstein BS
    Anaesthesia; 1984 Sep; 39(9):862-4. PubMed ID: 6545084
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Intracuff pressure and tracheal morbidity: influence of filling with saline during nitrous oxide anesthesia.
    Combes X; Schauvliege F; Peyrouset O; Motamed C; Kirov K; Dhonneur G; Duvaldestin P
    Anesthesiology; 2001 Nov; 95(5):1120-4. PubMed ID: 11684980
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Preventive measure against nitrous oxide induced volume and pressure changes of endotracheal tube cuffs.
    Konchigeri HN; Lee YE
    Middle East J Anaesthesiol; 1979 Oct; 5(5):369-73. PubMed ID: 542139
    [TBL] [Abstract][Full Text] [Related]  

  • 11. K-Y™ jelly inhibits increase in endotracheal tube cuff pressure during nitrous oxide exposure in vitro.
    Koyama Y; Oshika H; Nishioka H; Kamoshida N; Tanaka S; Inagawa G; Andoh T
    BMC Anesthesiol; 2018 Jul; 18(1):99. PubMed ID: 30055572
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Deflationary phenomenon of the nitrous oxide-filled endotracheal tube cuff after cessation of nitrous oxide administration.
    Karasawa F; Mori T; Kawatani Y; Ohshima T; Satoh T
    Anesth Analg; 2001 Jan; 92(1):145-8. PubMed ID: 11133617
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Profile soft-seal cuff, a new endotracheal tube, effectively inhibits an increase in the cuff pressure through high compliance rather than low diffusion of nitrous oxide.
    Karasawa F; Mori T; Okuda T; Satoh T
    Anesth Analg; 2001 Jan; 92(1):140-4. PubMed ID: 11133616
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Nitrous oxide and pressures exerted on the trachea by endotracheal tubes. Study on a tracheal model].
    Gateau O; Tchotourian S; Olivero de Rubiana JP; Gory G; Viars P
    Ann Fr Anesth Reanim; 1982; 1(5):491-5. PubMed ID: 7184344
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Tracheal tube cuff pressures. The effects of different gas mixtures.
    Raeder JC; Borchgrevink PC; Sellevold OM
    Anaesthesia; 1985 May; 40(5):444-7. PubMed ID: 4014621
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Volume and pressure of tracheal tube cuffs filled with air or nitrous oxide.].
    Peña EL; Gregori WM; Piccinini Filho L; Vieira JE; Mathias LA
    Rev Bras Anestesiol; 2004 Jun; 54(3):335-42. PubMed ID: 19471742
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [The rediffusion system. Limitation of nitrous oxide increases the cuff pressure of endotracheal tubes].
    Brandt L; Pokar H
    Anaesthesist; 1983 Sep; 32(9):459-64. PubMed ID: 6638471
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Cuff pressure changes due to diffusion of nitrous oxide. A contribution to the question of the in vivo-diffusion--area of the cuff].
    Brandt L; Pokar H; Renz D; Schütte H
    Anaesthesist; 1982 Jul; 31(7):345-8. PubMed ID: 7125178
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Outer diameter and shape of paediatric tracheal tube cuffs at higher inflation pressures.
    Bernet V; Dullenkopf A; Maino P; Weiss M
    Anaesthesia; 2005 Nov; 60(11):1123-8. PubMed ID: 16229698
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Tracheostomy and endotracheal tube cuff volume and pressure changes during thoracic operations.
    Stanley TH; Liu WS
    Ann Thorac Surg; 1975 Aug; 20(2):144-51. PubMed ID: 1164061
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.