These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
135 related articles for article (PubMed ID: 6664823)
1. Assay of midazolam and brotizolam in plasma by a gas chromatographic and a radioreceptor technique. Jochemsen R; Van Rijn PA; Hazelzet TG; Breimer DD Pharm Weekbl Sci; 1983 Dec; 5(6):308-12. PubMed ID: 6664823 [TBL] [Abstract][Full Text] [Related]
2. Comparative pharmacokinetics of midazolam and loprazolam in healthy subjects after oral administration. Jochemsen R; van Rijn PA; Hazelzet TG; van Boxtel CJ; Breimer DD Biopharm Drug Dispos; 1986; 7(1):53-61. PubMed ID: 2869795 [TBL] [Abstract][Full Text] [Related]
3. Determination of the benzodiazepine plasma concentrations in suicidal patients using a radioreceptor assay. de Jong LA; Verwey B; Essink G; Muntendam A; Zitman FG; Ensing K J Anal Toxicol; 2004 Oct; 28(7):587-92. PubMed ID: 15516318 [TBL] [Abstract][Full Text] [Related]
4. Pilot pharmacokinetic study of brotizolam, a thienodiazepine hypnotic, using electron-capture gas-liquid chromatography. Greenblatt DJ; Locniskar A; Shader RI Sleep; 1983; 6(1):72-6. PubMed ID: 6844800 [TBL] [Abstract][Full Text] [Related]
5. The usefulness of radioreceptor assay and gas liquid chromatography in pharmacokinetic studies on midazolam. Aaltonen L; Himberg JJ; Kanto J; Vuori A Int J Clin Pharmacol Ther Toxicol; 1985 May; 23(5):247-52. PubMed ID: 3159689 [TBL] [Abstract][Full Text] [Related]
6. Simultaneous determination of midazolam and its three hydroxy metabolites in human plasma by electron-capture gas chromatography without derivatization. De Kroon IF; Langendijk PN; De Goede PN J Chromatogr; 1989 Jun; 491(1):107-16. PubMed ID: 2793966 [TBL] [Abstract][Full Text] [Related]
7. Application of radioreceptor assay of benzodiazepines for toxicology. Aaltonen L; Scheinin M Acta Pharmacol Toxicol (Copenh); 1982 Mar; 50(3):206-12. PubMed ID: 7090843 [TBL] [Abstract][Full Text] [Related]
8. Brotizolam radioimmunoassay: development, evaluation, and application to human plasma samples. Bechtel WD; Weber KH J Pharm Sci; 1985 Dec; 74(12):1265-9. PubMed ID: 4087192 [TBL] [Abstract][Full Text] [Related]
9. Potential use of a radioreceptor assay for the determination of benzodiazepine compounds in serum. Bruhwyler J; Hassoun A J Anal Toxicol; 1993; 17(7):403-7. PubMed ID: 8309212 [TBL] [Abstract][Full Text] [Related]
10. Automated gas chromatography for studies of midazolam pharmacokinetics. Greenblatt DJ; Locniskar A; Ochs HR; Lauven PM Anesthesiology; 1981 Aug; 55(2):176-9. PubMed ID: 6114686 [TBL] [Abstract][Full Text] [Related]
11. A rapid and sensitive radioreceptor assay for benzodiazepine in plasma. Skolnick P; Goodwin FK; Paul SM Arch Gen Psychiatry; 1979 Jan; 36(1):78-80. PubMed ID: 32858 [TBL] [Abstract][Full Text] [Related]
12. Biochemical studies with the new thienotriazolo-diazepine brotizolam. Bechtel WD; Ensinger HA; Mierau J Arzneimittelforschung; 1986 Mar; 36(3A):534-40. PubMed ID: 3013211 [TBL] [Abstract][Full Text] [Related]
13. Determination of midazolam and two metabolites of midazolam in human plasma by gas chromatography--negative chemical-ionization mass spectrometry. Rubio F; Miwa BJ; Garland WA J Chromatogr; 1982 Dec; 233():157-65. PubMed ID: 7161330 [TBL] [Abstract][Full Text] [Related]
14. Quantitation by gas chromatography of the 1- and 4-hydroxy metabolites of midazolam in human plasma. Arendt RM; Greenblatt DJ; Garland WA Pharmacology; 1984; 29(3):158-64. PubMed ID: 6483962 [TBL] [Abstract][Full Text] [Related]
15. Characteristics of the association of brotizolam, a thieno-triazolo diazepine derivative, with the benzodiazepine receptor: a selective and high affinity ligand of the central type I benzodiazepine receptor. Hirouchi M; Mizutani H; Kohno Y; Kuriyama K Jpn J Pharmacol; 1992 Jul; 59(3):387-91. PubMed ID: 1359180 [TBL] [Abstract][Full Text] [Related]
16. Midazolam: radioimmunoassay for pharmacokinetic studies in man. Dixon R; Lucek R; Todd D; Walser A Res Commun Chem Pathol Pharmacol; 1982 Jul; 37(1):11-20. PubMed ID: 7122996 [TBL] [Abstract][Full Text] [Related]
17. Radioreceptor assay for benzodiazepines in biological fluids using a new dry and stable receptor preparation. Lund J Scand J Clin Lab Invest; 1981 May; 41(3):275-80. PubMed ID: 7313511 [TBL] [Abstract][Full Text] [Related]
18. Determination of midazolam (Versed) and its metabolites in plasma by high-performance liquid chromatography. Puglisi CV; Pao J; Ferrara FJ; de Silva JA J Chromatogr; 1985 Nov; 344():199-209. PubMed ID: 2935548 [TBL] [Abstract][Full Text] [Related]
19. [Determination of triazolam and midazolam in human plasma using gas chromatography with microelectron capture detection for clinical application]. Tsutsumi K; Iwao M; Kotegawa T; Imai H; Ohashi K; Nakano S Yakugaku Zasshi; 2014; 134(1):119-25. PubMed ID: 24389624 [TBL] [Abstract][Full Text] [Related]
20. Simultaneous screening and quantitative analysis of benzodiazepines by dual-channel gas chromatography using electron-capture and nitrogen-phosphorus detection. Lillsunde P; Seppälä T J Chromatogr; 1990 Nov; 533():97-110. PubMed ID: 2081783 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]