These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

114 related articles for article (PubMed ID: 666553)

  • 1. [2nd Generaltion of the Munich hip-joint-simulator (author's transl)].
    Ungethüm M; Hinterberger J
    Arch Orthop Trauma Surg (1978); 1978 May; 91(3):233-7. PubMed ID: 666553
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Analytical determination of the maximum hip joint force by means of a biomechanical model (author's transl)].
    Gebauer D; Orley H
    Biomed Tech (Berl); 1978 Dec; 23(12):290-4. PubMed ID: 728518
    [No Abstract]   [Full Text] [Related]  

  • 3. [Experimental investigations to the problem of anchorage of the hip joint endoprostheses (author's transl)].
    Grünert A; Ritter G
    Arch Orthop Unfallchir; 1973 Nov; 77(2):149-53. PubMed ID: 4773146
    [No Abstract]   [Full Text] [Related]  

  • 4. Discussion on the design of a hip joint simulator.
    Viceconti M; Cavallotti G; Andrisano AO; Toni A
    Med Eng Phys; 1996 Apr; 18(3):234-40. PubMed ID: 8718949
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [The force flow in hip joint-endoprostheses (author's transl)].
    Röhrle H; Scholten R; Sollbach W; Ritter G; Grünert A
    Arch Orthop Unfallchir; 1977 Jul; 89(1):49-60. PubMed ID: 889537
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A three-axis hip joint simulator for wear and friction studies on total hip prostheses.
    Saikko VO
    Proc Inst Mech Eng H; 1996; 210(3):175-85. PubMed ID: 8885654
    [TBL] [Abstract][Full Text] [Related]  

  • 7. ["Zuggurtungs"-hip joint endoprosthesis (author's transl)].
    Ritter G; Grünert A; Schweikert CH
    Arch Orthop Unfallchir; 1976 Oct; 86(1):1-14. PubMed ID: 985177
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Development of a ten-station, multi-axis hip joint simulator.
    Goldsmith AA; Dowson D
    Proc Inst Mech Eng H; 1999; 213(4):311-6. PubMed ID: 10466362
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Development of a knee joint simulator (author's transl)].
    Stallforth H; Ungethüm M
    Arch Orthop Unfallchir; 1977 Dec; 90(3):343-53. PubMed ID: 607926
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [The motility of hip joint endoprostheses (author's transl)].
    Weber U; Hoschek J
    Arch Orthop Trauma Surg (1978); 1979 Oct; 95(1-2):95-104. PubMed ID: 526131
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Biomechanical caused of loosening and breaking of the hip joint prothesess (author's transl)].
    Ritter G; Grünert A; Schweikert CH
    Arch Orthop Unfallchir; 1973 Nov; 77(2):154-64. PubMed ID: 4773147
    [No Abstract]   [Full Text] [Related]  

  • 12. Design and construction of a simulator for testing finger joint replacements.
    Schwarz ML; Bouman HW; Bayer M; Feinle P
    Biomed Tech (Berl); 2001 Jun; 46(6):176-80. PubMed ID: 11458771
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Functional results of total endoprostheses of the hip joint on account of coxarthrosis (author's transl)].
    Kubín Z; Charvátová B
    Acta Chir Orthop Traumatol Cech; 1981 Feb; 48(1):91-5. PubMed ID: 7223281
    [No Abstract]   [Full Text] [Related]  

  • 14. [Comments on the biostatical analysis of the hip joint II (author's transl)].
    Legal H; Reinecke M; Ruder H
    Z Orthop Ihre Grenzgeb; 1978; 116(6):889-96. PubMed ID: 726575
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [The medical insurance report in regard to replacement of the hip joint by a total endoprosthesis (TEP) (author's transl)].
    Missler H
    Offentl Gesundheitswes; 1977 May; 39(5):262-8. PubMed ID: 141639
    [No Abstract]   [Full Text] [Related]  

  • 16. [On the pressure distribution between femoral head and cup of a total hip joint prosthesis (author's transl)].
    Royczyk-Pflüger J
    Arch Orthop Unfallchir; 1976 Nov; 86(3):333-9. PubMed ID: 1008731
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [The use of carbon as manufacturing material of endoprotheses (author's transl)].
    Weber U; Rettig H
    Z Orthop Ihre Grenzgeb; 1979 Apr; 117(2):268-76. PubMed ID: 463217
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Mechanical factors of the loosening of hip-joint prosthetics and possibilities of their removal (author's transl)].
    Hoffmann-Daimler S
    Z Orthop Ihre Grenzgeb; 1974 Jun; 112(3):498-501. PubMed ID: 4277227
    [No Abstract]   [Full Text] [Related]  

  • 19. [Biostatic analysis of the hip-joint (author's transl)].
    Legal H; Ruder H
    Z Orthop Ihre Grenzgeb; 1977 Apr; 115(2):215-34. PubMed ID: 855410
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Mechanical and tribological properties of ceramic endoprostheses (totalhips) (author's transl)].
    Dörre E; Dawihl W
    Biomed Tech (Berl); 1978 Dec; 23(12):305-10. PubMed ID: 728520
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.