These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

64 related articles for article (PubMed ID: 6671912)

  • 21. Dissociation of a metal-backed polyethylene acetabular component. A case report.
    Bueche MJ; Herzenberg JE; Stubbs BT
    J Arthroplasty; 1989; 4(1):39-41. PubMed ID: 2926408
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Structural mechanical properties of polyethylene acetabular cups.
    Burstein AH
    Hip; 1981; ():293-7. PubMed ID: 7333892
    [No Abstract]   [Full Text] [Related]  

  • 23. Design optimization of cementless metal-backed cup prostheses using the concept of functionally graded material.
    Hedia HS; El-Midany TT; Shabara MA; Fouda N
    Biomed Mater; 2006 Sep; 1(3):127-33. PubMed ID: 18458393
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Transient elastohydrodynamic lubrication analysis of metal-on-metal hip implant under simulated walking conditions.
    Liu F; Jin ZM; Hirt F; Rieker C; Roberts P; Grigoris P
    J Biomech; 2006; 39(5):905-14. PubMed ID: 16199048
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Comparison of polyethylene wear in machined versus molded polyethylene.
    Bankston AB; Keating EM; Ranawat C; Faris PM; Ritter MA
    Clin Orthop Relat Res; 1995 Aug; (317):37-43. PubMed ID: 7671494
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Wear mechanisms in ceramic hip implants.
    Slonaker M; Goswami T
    J Surg Orthop Adv; 2004; 13(2):94-105. PubMed ID: 15281406
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Total hip prosthesis with metal-on-metal slide matching--current developments based on long-term observations].
    Weber BG
    Ther Umsch; 1995 Jul; 52(7):470-2. PubMed ID: 7631279
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Cracking and impingement in ultra-high-molecular-weight polyethylene acetabular liners.
    Birman MV; Noble PC; Conditt MA; Li S; Mathis KB
    J Arthroplasty; 2005 Oct; 20(7 Suppl 3):87-92. PubMed ID: 16214008
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Re: "a novel technique for the removal of well-fixed cementless, large-diameter metal-on-metal acetabular components" by Olyslaegers et al.
    Krikler S
    J Arthroplasty; 2009 Jan; 24(1):160; author reply 160. PubMed ID: 18824325
    [No Abstract]   [Full Text] [Related]  

  • 30. The role of backside polishing, cup angle, and polyethylene thickness on the contact stresses in metal-backed acetabular components.
    Kurtz SM; Edidin AA; Bartel DL
    J Biomech; 1997 Jun; 30(6):639-42. PubMed ID: 9165399
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Development and validation of a method for wear measurement of polyethylene hip acetabulum with metal backing using roentgen images].
    Gölzhäuser G; Wimmer MA; Berzins A; Sumner DR; Scheuvens BJ; Schneider E
    Biomed Tech (Berl); 1998; 43 Suppl():66-7. PubMed ID: 9859260
    [No Abstract]   [Full Text] [Related]  

  • 32. Choosing the socket in total hip arthroplasty.
    Davey JR
    Can J Surg; 1995 Feb; 38 Suppl 1():S46-8. PubMed ID: 7874628
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Long-term results of cemented and screwed acetabular components.
    Agrifoglio E; Federici A; Sanguineti F; Maxena S; Giacchè P
    Ital J Orthop Traumatol; 1993; 19(1):71-8. PubMed ID: 8567260
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Comparison of the in vivo wear rates of 43 surgically retrieved direct compression molded and ram extruded ultra high molecular weight polyethylene acetabular components.
    Rentfrow ED; James SP; Beauregard GP; Lee KR; McLaughlin JR
    Biomed Sci Instrum; 1996; 32():135-41. PubMed ID: 8672661
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Wear of polyethylene in the total hip prosthesis.
    Rose RM; Radin EL
    Clin Orthop Relat Res; 1982 Oct; (170):107-15. PubMed ID: 7127935
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Mechanical inspection of the intermediary coated prosthesis].
    Greco G
    Chir Organi Mov; 1980; 66(1):103-16. PubMed ID: 7249838
    [No Abstract]   [Full Text] [Related]  

  • 37. Pelvic stresses in vitro--II. A study of the efficacy of metal-backed acetabular prostheses.
    Finlay JB; Bourne RB; Landsberg RP; Andreae P
    J Biomech; 1986; 19(9):715-25. PubMed ID: 3793746
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Fracture of polyethylene acetabular cups. Report of two cases.
    Salvati EA; Wright TM; Burstein AH; Jacobs B
    J Bone Joint Surg Am; 1979 Dec; 61(8):1239-42. PubMed ID: 511885
    [No Abstract]   [Full Text] [Related]  

  • 39. Acetabular wear.
    Freeman MA
    J Arthroplasty; 1996 Jan; 11(1):122. PubMed ID: 8676113
    [No Abstract]   [Full Text] [Related]  

  • 40. Superolateral wear of the acetabulum.
    Murray DW; O'Connor JJ
    J Bone Joint Surg Br; 1998 Mar; 80(2):197-200. PubMed ID: 9546443
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 4.