These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

96 related articles for article (PubMed ID: 6673247)

  • 41. Use of arterial patch to improve re-endothelialization in a sheep model of open carotid endarterectomy. An incentive to use internal thoracic artery as an on-lay patch following coronary endarterecomy?
    Bezon E; Khalifa AA; Le Gal G; Choplain JN; Mansourati J; Barra JA
    Interact Cardiovasc Thorac Surg; 2009 May; 8(5):543-7. PubMed ID: 19223308
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Electrochemistry of thrombosis--an aid in the selection of prosthetic materials.
    Sawyer PN; Srinivasan S; Chopra PS; Martin JG; Lucas T; Burrowes CB; Sauvage L
    J Biomed Mater Res; 1970 Mar; 4(1):43-55. PubMed ID: 5434815
    [No Abstract]   [Full Text] [Related]  

  • 43. Glutaraldehyde-treated human vein as arterial substitute in the rabbit.
    Yamaguchi H; Berglin E; Björkerud S; Mykén P; Nyström U; Roberts D
    Life Support Syst; 1983; 1 Suppl 1():386-9. PubMed ID: 6336451
    [No Abstract]   [Full Text] [Related]  

  • 44. Experimental carotid stenosis due to fibrous intimal hyperplasia.
    Carson SN; Esquivel CO; French SW
    Surg Gynecol Obstet; 1981 Dec; 153(6):883-8. PubMed ID: 7302814
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Viability of engineered vessels as arterial substitutes.
    García-Honduvilla N; Domínguez B; Pascual G; Escudero C; Minguela F; Bellón JM; Buján J
    Ann Vasc Surg; 2008 Mar; 22(2):255-65. PubMed ID: 18346580
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Electrolour: a new vascular interface.
    Sharp WV; Gardner DL; Andresen GJ; Wright J
    Trans Am Soc Artif Intern Organs; 1968; 14():73-7. PubMed ID: 5701577
    [No Abstract]   [Full Text] [Related]  

  • 47. Eight years of clinical endothelial cell transplantation. Closing the gap between prosthetic grafts and vein grafts.
    Meinhart J; Deutsch M; Zilla P
    ASAIO J; 1997; 43(5):M515-21. PubMed ID: 9360096
    [TBL] [Abstract][Full Text] [Related]  

  • 48. An investigation into vascular prosthesis modified with an electron beam.
    Lowkis B; Szymonowicz M; Rutkowski J
    Polim Med; 1997; 27(3-4):19-26. PubMed ID: 9513250
    [TBL] [Abstract][Full Text] [Related]  

  • 49. A new plastic interface which has antithrombotic characteristics and appears to mimic the vascular interface.
    Sawyer PN; Kaplitt M; Afshar A; Miller M; Postal RH
    Trans Am Soc Artif Intern Organs; 1966; 12():183-7. PubMed ID: 5960699
    [No Abstract]   [Full Text] [Related]  

  • 50. The importance of zeta potential, ultrastructure, and electrical conductivity to the in vivo performance of polyurethane-carbon black vascular prostheses.
    Taylor BC; Sharp WV; Wright JI; Ewing KL; Wilson CL
    Trans Am Soc Artif Intern Organs; 1971; 17():22-6. PubMed ID: 5158098
    [No Abstract]   [Full Text] [Related]  

  • 51. Metallic and plastic prosthetic devices as vascular wall substitutes: biophysical criteria and methods for evaluation.
    Sawyer PN; Srinivasan S
    J Biomed Mater Res; 1967 Mar; 1(1):83-101. PubMed ID: 5605618
    [No Abstract]   [Full Text] [Related]  

  • 52. Essential criteria for the selection of metallic and non-metallic vascular prostheses.
    Sawyer PN; Srinivasan S
    Adv Biomed Eng Med Phys; 1970; 3():273-94. PubMed ID: 5527793
    [No Abstract]   [Full Text] [Related]  

  • 53. [Development of vascular prosthesis with excellent elasticity: preliminary report].
    Morita I; Tabuchi A; Fujiwara T; Katsumura T; Takano Y; Ezaki Y
    Nihon Geka Gakkai Zasshi; 1994 Nov; 95(11):848. PubMed ID: 7830714
    [No Abstract]   [Full Text] [Related]  

  • 54. Extending the functional life of bioresorbable yarns for vascular grafts.
    Galletti PM; Ip TK; Chiu TH; Nyilas E; Trudeli LA; Sasken H
    Trans Am Soc Artif Intern Organs; 1984; 30():399-400. PubMed ID: 6533914
    [No Abstract]   [Full Text] [Related]  

  • 55. A method to prevent torsion of arterial prosthetic grafts.
    Belin RP; Griffen WO
    J Thorac Cardiovasc Surg; 1967 Jul; 54(1):9. PubMed ID: 6027864
    [No Abstract]   [Full Text] [Related]  

  • 56. Biocompatibie materials for use in the vascular system.
    Grode GA; Falb RD; Crowley JP
    J Biomed Mater Res; 1972; 6(4):77-84. PubMed ID: 5045265
    [No Abstract]   [Full Text] [Related]  

  • 57. Problems of materials in mechanical heart systems.
    Akutsu T; Kantrowitz A
    J Biomed Mater Res; 1967 Mar; 1(1):33-54. PubMed ID: 5605614
    [No Abstract]   [Full Text] [Related]  

  • 58. Small vessel replacement with elastomeric protein composite materials: preliminary studies.
    Kambic H; Murabayashi S; Yozu R; Morimoto T; Furuse M; Harasaki H; George C; Helmus M; Snyder R; Nose Y
    Trans Am Soc Artif Intern Organs; 1984; 30():406-10. PubMed ID: 6533916
    [No Abstract]   [Full Text] [Related]  

  • 59. Failure of La to block completely either spikes or slow discharges in sheep carotid arteries [proceedings].
    Keatinge WR
    J Physiol; 1978 Sep; 282():19P-20P. PubMed ID: 722519
    [No Abstract]   [Full Text] [Related]  

  • 60. [Temporary synthetic arterial shunt. An experimental study].
    Smolarek F; Stawarz B; Klepko W; Mastalerski J; Kalczak M
    Polim Med; 1975; 5(1):47-9. PubMed ID: 1187490
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.