These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 6674739)

  • 1. In vitro testing of a new driver for the pneumatic total artificial heart with inherent cardiac output measuring system.
    Frumento CI; Auch WD; Frumento AS
    Med Prog Technol; 1983-1984; 10(2):97-107. PubMed ID: 6674739
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Determining arterial pressure, left atrial pressure and cardiac output from the left pneumatic drive line of the total artificial heart.
    Rosenberg G; Landis DL; Phillips WM; Stallsmith J; Pierce WS
    Trans Am Soc Artif Intern Organs; 1978; 24():341-4. PubMed ID: 362675
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Enhanced cardiac thermal dilution measurement of cardiac output, volumes, regurgitation, valve effective diameters, ventricular power and efficiency -- Feasibility analysis using digital simulation.
    Donovan FM; Taylor BC
    Technol Health Care; 2001; 9(5):377-86. PubMed ID: 11673669
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Fuzzy logic automatic control of the Phoenix-7 total artificial heart.
    Hsu CH
    J Artif Organs; 2004; 7(2):69-76. PubMed ID: 15309673
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Noninvasive monitoring of pneumatically driven blood pumps based on measurements of air volume flow in the drive hose].
    Schmitz KP; Nabel HJ; Scharf W; Urbaszek W; Klinkmann H
    Z Gesamte Inn Med; 1987 Nov; 42(22):645-9. PubMed ID: 3442074
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Factors influencing the accuracy of the cardiac output monitoring and diagnostic unit for pneumatic artificial hearts.
    Shaw WJ; Pantalos GM; Everett S; Olsen DB
    ASAIO Trans; 1990; 36(3):M264-8. PubMed ID: 2252674
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Total replacement artificial heart and driving system with inherent regulation of cardiac output.
    Kwan-Gett CS; Wu Y; Collan R; Jacobsen S; Kolff WJ
    Trans Am Soc Artif Intern Organs; 1969; 15():245-66. PubMed ID: 5791395
    [No Abstract]   [Full Text] [Related]  

  • 8. An electric model with time varying resistance for a pneumatic membrane blood pump.
    Jin Z; Qin J
    ASAIO J; 1993; 39(1):56-61. PubMed ID: 8439682
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The analysis of driving mode influence on energy dissipation in pneumatic artificial heart chambers.
    Nawrat Z; Malota Z
    Artif Organs; 1998 Oct; 22(10):898-904. PubMed ID: 9790090
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Bubble observation and transient pressure signals in mechanical heart valve cavitation study.
    Lijun X; Hock YJ; Hwang NH
    J Heart Valve Dis; 2003 Mar; 12(2):235-44. PubMed ID: 12701797
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Testing the regulation mechanism in inserting an artificial heart by model simulation].
    Hecht J; Körner E
    Z Exp Chir Transplant Kunstliche Organe; 1987; 20(2):75-82. PubMed ID: 3604358
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Hemodynamics study of cardiovascular system in vitro simulation].
    Li H; Qian K
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2006 Aug; 23(4):778-80. PubMed ID: 17002106
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Artificial heart driven by an automatic driving system.
    Unger F; Deutsch M; Eckersberger F; Losert U; Stellwag F; Thoma H; Wolner E; Polzer K; Navratil J
    Med Instrum; 1977; 11(4):208-11. PubMed ID: 895594
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The artificial heart in human subjects.
    Kolff J; Deeb GM; Cavarocchi NC; Riebman JB; Olsen DB; Robbins PS
    J Thorac Cardiovasc Surg; 1984 Jun; 87(6):825-31. PubMed ID: 6727405
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Determination of cardiac output of the artificial heart from the drive air flow.
    Hanzelka P; Vasků J; Urbánek P; Vasků J; Urbánek E
    Artif Organs; 1979 Aug; 3(3):277-8. PubMed ID: 161167
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Biophysical phenomena in the circulatory system in indirect measurement of the arterial pressure and an analysis of the devices for its measurement].
    Rudenko MIu; Alekseev VB; Matsiuk SA
    Med Tekh; 1986; (5):26-35. PubMed ID: 3784860
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A cardiac output monitor and diagnostic unit for pneumatically driven artificial hearts.
    Willshaw P; Nielsen SD; Nanas J; Pichel RH; Olsen DB
    Artif Organs; 1984 May; 8(2):215-9. PubMed ID: 6233957
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Influence of aortic compliance on coronary blood flow.
    Abel FL
    Circ Shock; 1984; 12(4):265-76. PubMed ID: 6722994
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Vascular tone estimation in patients implanted with the AbioCor implantable replacement heart.
    Kung RT; Zhang H
    Artif Organs; 2004 Jun; 28(6):543-8. PubMed ID: 15153146
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The role of pulse transit time as an index of arterial stiffness during exercise.
    Kounalakis SN; Geladas ND
    Cardiovasc Eng; 2009 Sep; 9(3):92-7. PubMed ID: 19657732
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.