BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

455 related articles for article (PubMed ID: 6675275)

  • 1. [Metal osteosynthesis in fresh closed fractures of the diaphyses of long tubular bones].
    Beliakov AA
    Vestn Khir Im I I Grek; 1983 Nov; 131(11):95-9. PubMed ID: 6675275
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Intramedullary metal osteosynthesis as re-osteosynthesis of long bones].
    Höhndorf H
    Beitr Orthop Traumatol; 1974 Aug; 21(8):466-72. PubMed ID: 4409902
    [No Abstract]   [Full Text] [Related]  

  • 3. [Compression-distraction osteosynthesis in pseudarthroses of long tubular bones].
    Shumada IV; Zhila IuS; Rybachuk OI
    Vestn Khir Im I I Grek; 1976 Apr; 116(4):90-4. PubMed ID: 960506
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Closed osteosynthesis in fractures of long bones].
    Barskiĭ AV; Semenov NP; Glukhov VF
    Ortop Travmatol Protez; 1982 Jan; (1):24-6. PubMed ID: 7063204
    [No Abstract]   [Full Text] [Related]  

  • 5. [Comparative evaluation of different methods of osteosynthesis in the treatment of diaphyseal fractures of long tubular bones].
    Balakina VS
    Ortop Travmatol Protez; 1976 May; (5):5-8. PubMed ID: 1012664
    [No Abstract]   [Full Text] [Related]  

  • 6. [Metal osteosynthesis and bone homoplasty in fractures and pseudarthroses of the long tubular bones].
    Abramov IuG
    Khirurgiia (Mosk); 1974 Nov; 0(11):18-22. PubMed ID: 4610270
    [No Abstract]   [Full Text] [Related]  

  • 7. [Reosteosynthesis of long tubular bones].
    Probst J
    Hefte Unfallheilkd; 1973; 112():1-139. PubMed ID: 4570585
    [No Abstract]   [Full Text] [Related]  

  • 8. [Compression-distraction osteosynthesis in the treatment of ununited fractures and pseudarthroses of the long tubular bones].
    Vartanian VK; Afaunov AI
    Khirurgiia (Mosk); 1976 May; (5):125-30. PubMed ID: 966511
    [No Abstract]   [Full Text] [Related]  

  • 9. Rigid osteosynthesis in open diaphyseal fractures of the long bones: immediate or deferred treatment.
    Santoro D; Grassi G
    Ital J Orthop Traumatol; 1979 Aug; 5(2):153-61. PubMed ID: 548510
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Treatment of open diaphysary fractures of the long tubular bones by means of metallic osteosynthesis].
    Krupko IL; Zkukov PP
    Vestn Khir Im I I Grek; 1967 Oct; 99(10):73-9. PubMed ID: 5603751
    [No Abstract]   [Full Text] [Related]  

  • 11. [Open diaphyseal fractures of the long tubular bones and their treatment].
    Bratash BM
    Vestn Khir Im I I Grek; 1975 Nov; 115(11):86-90. PubMed ID: 1108381
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Biomechanical aspects of osteosynthesis with the bone screws in closed oblique and spiral fractures of long tubular bones].
    Saakian TsA
    Ortop Travmatol Protez; 1979 Jun; (6):10-3. PubMed ID: 471446
    [No Abstract]   [Full Text] [Related]  

  • 13. [Surgical treatment of fractures of the long bones in children. Interference between osteosynthesis and the physiological processes of consolidation. Therapeutic indications].
    Metaizeau JP; Ligier JN
    J Chir (Paris); 1984; 121(8-9):527-37. PubMed ID: 6501457
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Comparative evaluation and indications for different methods of osteosynthesis in closed fractures of bones of the limbs].
    Kaplan AV; Lirtsman VM
    Ortop Travmatol Protez; 1975 Oct; (10):1-5. PubMed ID: 1208045
    [No Abstract]   [Full Text] [Related]  

  • 15. [Immobilization of bone fragments during multiple and combined diaphyseal fractures of long tubular bones].
    Dem'nov VM; Kulik VI; Karptsov VI
    Ortop Travmatol Protez; 1982 Mar; (3):9-13. PubMed ID: 7099610
    [No Abstract]   [Full Text] [Related]  

  • 16. Primary internal fixation of open fractures: a retrospective study of the use of metallic internal fixation in fresh open fractures.
    Ketenjian AY; Shelton ML
    J Trauma; 1972 Sep; 12(9):756-63. PubMed ID: 5073398
    [No Abstract]   [Full Text] [Related]  

  • 17. [Selection of the treatment method in diaphyseal fractures of 2 segments of the upper or lower limbs].
    Trubnikov VF; Khimenko MF; Popov IF; Malakhov AI; Kovalev SI
    Vestn Khir Im I I Grek; 1985 Feb; 134(2):71-4. PubMed ID: 4002500
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Osteosynthesis of oblique and spiral fractures of the long tubular bones using fixation devices made of polyamide-12].
    Rublenik IM
    Vestn Khir Im I I Grek; 1978 Aug; 121(8):102-5. PubMed ID: 695190
    [No Abstract]   [Full Text] [Related]  

  • 19. [Internal and extrafocal compression osteosynthesis for pseudarthrosis].
    Skoblin AP; Zhila IuS
    Vestn Khir Im I I Grek; 1971 Aug; 107(8):88-93. PubMed ID: 4945976
    [No Abstract]   [Full Text] [Related]  

  • 20. Early results with the new internal fixator systems LCP and LISS: a prospective study.
    Hernanz González Y; Díaz Martín A; Jara Sánchez F; Resines Erasun C
    Acta Orthop Belg; 2007 Feb; 73(1):60-9. PubMed ID: 17441660
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 23.