These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

259 related articles for article (PubMed ID: 6675670)

  • 1. [Quantitative aortic flow and cardiac output volume determinations in rabbits using tetrapolar impedance plethysmography].
    Schäfer RO; Bruchovetzkij VI; Sutschkov VV
    Biomed Biochim Acta; 1983; 42(10):1287-97. PubMed ID: 6675670
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Impedance cardiography by use of a spot-electrode array to track changes in cardiac output in anesthetized dogs.
    Kiesler TW; Voorhees WD; Wessale JL; Pham CK
    J Am Vet Med Assoc; 1990 Jun; 196(11):1804-10. PubMed ID: 2351600
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The measurement of cardia output by the thoracic impedance method.
    Adamicza A; Tutsek L; Nagy S
    Acta Physiol Hung; 1988; 71(3):395-408. PubMed ID: 3421117
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Impedance cardiography in the measurement of cardiac output: studies in rabbits.
    Pappas CG; Wang X; Connolly RJ; Schwaitzberg SD
    J Surg Res; 1995 Oct; 59(4):504-10. PubMed ID: 7564325
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Use of the tetrapolar rheography method for assessment of the circulatory system].
    Tikhomirov IB; Turchaninova VF; Selivanenko VT; Staferov VA
    Kosm Biol Aviakosm Med; 1977; 11(4):70-4. PubMed ID: 333176
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The measurement of cardiac output by electrical impedance plethysmography in pregnancy. Are the assumptions valid?
    de Swiet M; Talbert DG
    Br J Obstet Gynaecol; 1986 Jul; 93(7):721-6. PubMed ID: 3730343
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Determination of cardiac output by thoracic electric impedance: comparison with thermodilution].
    Delfino M; Carlone S; Angelici E; Zona C; Del Bolgia F; Nigri A; Serra P; Reale A
    G Ital Cardiol; 1984 Feb; 14(2):101-7. PubMed ID: 6714547
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Tetrapolar modification of integral body impedance plethysmography].
    Guseĭnov BA; Shishin VI
    Anesteziol Reanimatol; 1989; (3):68-70. PubMed ID: 2802253
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Evaluation of a tetrapolar rheographic method for determining cardiac output in rats].
    Ismailov ShI; Baranov VS; Medvedev OS; Matsievskiĭ DD; Suchkov VV
    Fiziol Zh SSSR Im I M Sechenova; 1982 Aug; 68(8):1171-4. PubMed ID: 6215267
    [No Abstract]   [Full Text] [Related]  

  • 10. Comparative study on measurement of stroke volume by impedance method and electromagnetic flow method.
    Yu-tang S; Wen-ti S
    Chin Med J (Engl); 1979 Feb; 92(2):79-84. PubMed ID: 105857
    [No Abstract]   [Full Text] [Related]  

  • 11. [Determination of cardiac output in small laboratory animals by tetrapolar rheography].
    Karpitskiĭ VV; Slovesnov SV; Rerikh RA
    Patol Fiziol Eksp Ter; 1986; (1):74-7. PubMed ID: 3703589
    [No Abstract]   [Full Text] [Related]  

  • 12. Changes in aortic blood pressure and cardiac output curves as induced by stenosis of the descending thoracic aorta.
    Di Lavore P; Gattullo D; Losano G; Millesimo G; Vacca G
    Boll Soc Ital Biol Sper; 1983 May; 59(5):584-9. PubMed ID: 6882556
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Assessment of cardiac output during exercise. Transthoracic impedance vs. heart rate alone.
    Horstmann E; Könn B
    Med Prog Technol; 1993-1994; 19(4):173-8. PubMed ID: 8052172
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Comparison of direct and indirect methods of determining cardiac output].
    Doroshev VG; Popov NN; Katuntsev VP; Lapshina NA; Kulikov OB
    Kosm Biol Aviakosm Med; 1981; 15(4):7-9. PubMed ID: 6455561
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of changes in cardiac output from the electrical impedance waveform in the forearm.
    Wang JJ; Wang PW; Liu CP; Lin SK; Hu WC; Kao T
    Physiol Meas; 2007 Sep; 28(9):989-99. PubMed ID: 17827648
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Reliability and effectiveness of monitoring the stroke and minute volume of the heart by Kubicek's rheographic method].
    Genin AM; Zingerman LS; Maksimov DG; Belozerov GE; Katuntsev VP
    Kosm Biol Aviakosm Med; 1984; 18(3):9-14. PubMed ID: 6737989
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Measurement of cardiac output by electrical impedance plethysmography during respiration and in apnea].
    Tanguy RL; Morin JF; Deredec D; Guedes Y; Riche C; Egreteau JP
    Ann Anesthesiol Fr; 1980; 21(5):567-71. PubMed ID: 6109507
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Method of determining the cardiac blood output of animals].
    Belkamiia GS; Dartsmeliia VA; Demin AN
    Fiziol Zh SSSR Im I M Sechenova; 1985 Mar; 71(3):383-9. PubMed ID: 3922811
    [No Abstract]   [Full Text] [Related]  

  • 19. [Determination of the stroke and minute blood volumes in monkeys by tetrapolar thoracic rheography].
    Belkaniia GS; Dartsmeliia VA
    Kosm Biol Aviakosm Med; 1983; 17(4):75-8. PubMed ID: 6413752
    [No Abstract]   [Full Text] [Related]  

  • 20. [The effects of changes in mean aortic pressure on the reliability of cardiac output determination from the aortic pressure curve (author's transl)].
    Schemmann D; Purschke R
    Anaesthesist; 1980 May; 29(5):226-34. PubMed ID: 7425255
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.