These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 6685599)

  • 1. In vitro analysis of thermal transport in coronary sinus thermodilution catheters.
    Bålfors E; Häggmark S; Ariola S; Biber B; Pontèn J; Reiz S
    Clin Physiol; 1983 Oct; 3(5):469-76. PubMed ID: 6685599
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The continuous thermodilution method for measuring high blood flows.
    Häggmark S; Biber B; Sjödin JG; Winsö O; Gustavsson B; Reiz S
    Scand J Clin Lab Invest; 1982 Jun; 42(4):315-21. PubMed ID: 7134816
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Continuous infusion thermodilution for assessment of coronary flow: theoretical background and in vitro validation.
    van't Veer M; Geven MC; Rutten MC; van der Horst A; Aarnoudse WH; Pijls NH; van de Vosse FN
    Med Eng Phys; 2009 Jul; 31(6):688-94. PubMed ID: 19237308
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Measurement of coronary sinus flow by thermodilution: observations on the effect of respiration and a review of the potential sources of error.
    Stewart JT; Gray HH; Camm AJ
    Cathet Cardiovasc Diagn; 1989 Aug; 17(4):207-11. PubMed ID: 2670243
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Measurement of regional and global coronary sinus blood flow with the continuous thermodilution technique. I. Method and experimental studies (author's transl)].
    Kupper W; Bleifeld W
    Z Kardiol; 1979 Nov; 68(11):740-7. PubMed ID: 543192
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Continuous versus bolus thermodilution cardiac output measurements--a comparative study.
    Mihaljevic T; von Segesser LK; Tönz M; Leskosek B; Seifert B; Jenni R; Turina M
    Crit Care Med; 1995 May; 23(5):944-9. PubMed ID: 7736755
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Experimental evaluation of the reliance of coronary sinus blood flow (CSF) and great cardiac vein blood flow (GCVF) measured by local thermodilution method].
    Obata H; Nishijima H; Yasuda H
    Hokkaido Igaku Zasshi; 1991 Mar; 66(2):161-9. PubMed ID: 2060904
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Coronary sinus blood flow determination by the thermodilution technique: influence of catheter position and respiration.
    Bagger JP
    Cardiovasc Res; 1985 Jan; 19(1):27-31. PubMed ID: 3986850
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Direct volumetric blood flow measurement in coronary arteries by thermodilution.
    Aarnoudse W; Van't Veer M; Pijls NH; Ter Woorst J; Vercauteren S; Tonino P; Geven M; Rutten M; van Hagen E; de Bruyne B; van de Vosse F
    J Am Coll Cardiol; 2007 Dec; 50(24):2294-304. PubMed ID: 18068038
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of the continuous thermal dilution technique for measurement of coronary blood flow.
    Gisselsson L; Ericsson M
    Ups J Med Sci; 1981; 86(1):83-92. PubMed ID: 7029852
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Validation of bedside measurements of absolute human renal blood flow by a continuous thermodilution technique.
    Haywood GA; Stewart JT; Counihan PJ; Sneddon JF; Tighe D; Bennett ED; McKenna WJ
    Crit Care Med; 1992 May; 20(5):659-64. PubMed ID: 1572191
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Continuous cardiac output monitoring during adult liver transplantation: thermal filament technique versus bolus thermodilution.
    Greim CA; Roewer N; Thiel H; Laux G; Schulte am Esch J
    Anesth Analg; 1997 Sep; 85(3):483-8. PubMed ID: 9296398
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Computherm. A new device for measurement of coronary blood flow using the continuous thermodilution technique.
    Ericsson M; Johansson H; Larsson R; Gisselsson L
    Ups J Med Sci; 1982; 87(1):27-31. PubMed ID: 7123701
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Measurement of flow in large veins by the continuous thermodilution method.
    Louagie Y; Vanbogaert E; Salliez A; Bachy JL; Lambotte L
    Res Exp Med (Berl); 1986; 186(2):133-9. PubMed ID: 3715208
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Inverse thermodilution with conventional pulmonary artery catheters for the assessment of cerebral, hepatic, renal, and femoral blood flow.
    Ganter CC; Buser C; Haenggi M; Mattes H; Takala J; Jakob SM
    Shock; 2009 Aug; 32(2):194-200. PubMed ID: 19033887
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Thermodilution cardiac output. Cold vs room temperature injectate and the importance of measuring the injectate temperature in the right atrium.
    Berthelsen PG; Eldrup N; Nilsson LB; Rasmussen JP
    Acta Anaesthesiol Scand; 2002 Oct; 46(9):1103-10. PubMed ID: 12366505
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Measurement of human portal blood flow by continuous thermodilution.
    Kinoshita H; Sakai K; Kubo S; Yamazaki O
    J Surg Res; 1989 Mar; 46(3):235-40. PubMed ID: 2921863
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Determination of the precision error of the pulmonary artery thermodilution catheter using an in vitro continuous flow test rig.
    Yang XX; Critchley LA; Joynt GM
    Anesth Analg; 2011 Jan; 112(1):70-7. PubMed ID: 21127281
    [TBL] [Abstract][Full Text] [Related]  

  • 19. In vitro determination of accuracy of cardiac output measurements by thermal dilution.
    Bilfinger TV; Lin CY; Anagnostopoulos CE
    J Surg Res; 1982 Nov; 33(5):409-14. PubMed ID: 7132327
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Catheter-Based Measurements of Absolute Coronary Blood Flow and Microvascular Resistance: Feasibility, Safety, and Reproducibility in Humans.
    Xaplanteris P; Fournier S; Keulards DCJ; Adjedj J; Ciccarelli G; Milkas A; Pellicano M; Van't Veer M; Barbato E; Pijls NHJ; De Bruyne B
    Circ Cardiovasc Interv; 2018 Mar; 11(3):e006194. PubMed ID: 29870386
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.