These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
140 related articles for article (PubMed ID: 6686899)
1. Improvements in the spectral difference method for measuring ultrasonic attenuation. Insana M; Zagzebski J; Madsen E Ultrason Imaging; 1983 Oct; 5(4):331-45. PubMed ID: 6686899 [TBL] [Abstract][Full Text] [Related]
2. Statistical uncertainty in ultrasonic backscatter and attenuation coefficients determined with a reference phantom. Yao LX; Zagzebski JA; Madsen EL Ultrasound Med Biol; 1991; 17(2):187-94. PubMed ID: 2053215 [TBL] [Abstract][Full Text] [Related]
3. Theoretical and phantom based investigation of the impact of sound speed and backscatter variations on attenuation slope estimation. Omari E; Lee H; Varghese T Ultrasonics; 2011 Aug; 51(6):758-67. PubMed ID: 21477832 [TBL] [Abstract][Full Text] [Related]
4. Evaluation of the impact of backscatter intensity variations on ultrasound attenuation estimation. Omari EA; Varghese T; Madsen EL; Frank G Med Phys; 2013 Aug; 40(8):082904. PubMed ID: 23927359 [TBL] [Abstract][Full Text] [Related]
5. Method of data reduction for accurate determination of acoustic backscatter coefficients. Madsen EL; Insana MF; Zagzebski JA J Acoust Soc Am; 1984 Sep; 76(3):913-23. PubMed ID: 6491053 [TBL] [Abstract][Full Text] [Related]
6. Hybrid spectral domain method for attenuation slope estimation. Kim H; Varghese T Ultrasound Med Biol; 2008 Nov; 34(11):1808-19. PubMed ID: 18621468 [TBL] [Abstract][Full Text] [Related]
7. Ultrasonic attenuation estimation in-vivo using the difference ratio correction method. Zhou K; Zhang D; Lin C; Zhu S J Acoust Soc Am; 1992 Nov; 92(5):2532-8. PubMed ID: 1479118 [TBL] [Abstract][Full Text] [Related]
8. Microscopic mechanism of attenuation of compressional ultrasonic waves in tissue-mimicking phantom materials. Wu EX; Goodsitt MM; Madsen EL Ultrason Imaging; 1992 Apr; 14(2):121-33. PubMed ID: 1604754 [TBL] [Abstract][Full Text] [Related]
9. X-ray linear attenuation coefficients in the mammographic range for ultrasonic breast phantom materials. Burke TM; Madsen EL; Zagzebski JA Radiology; 1982 Mar; 142(3):755-7. PubMed ID: 7063698 [TBL] [Abstract][Full Text] [Related]
10. Attenuation and backscatter estimation using video signal analysis applied to B-mode images. Knipp BS; Zagzebski JA; Wilson TA; Dong F; Madsen EL Ultrason Imaging; 1997 Jul; 19(3):221-33. PubMed ID: 9447670 [TBL] [Abstract][Full Text] [Related]
11. Estimation of Tissue Attenuation from Ultrasonic B-Mode Images-Spectral-Log-Difference and Method-of-Moments Algorithms Compared. Brandner DM; Cai X; Foiret J; Ferrara KW; Zagar BG Sensors (Basel); 2021 Apr; 21(7):. PubMed ID: 33916496 [TBL] [Abstract][Full Text] [Related]
12. Oil-in-gelatin dispersions for use as ultrasonically tissue-mimicking materials. Madsen EL; Zagzebski JA; Frank GR Ultrasound Med Biol; 1982; 8(3):277-87. PubMed ID: 7101576 [TBL] [Abstract][Full Text] [Related]
13. Dedicated phantom materials for spectral radiography and CT. Shikhaliev PM Phys Med Biol; 2012 Mar; 57(6):1575-93. PubMed ID: 22397927 [TBL] [Abstract][Full Text] [Related]
14. Interlaboratory comparison of ultrasonic backscatter, attenuation, and speed measurements. Madsen EL; Dong F; Frank GR; Garra BS; Wear KA; Wilson T; Zagzebski JA; Miller HL; Shung KK; Wang SH; Feleppa EJ; Liu T; O'Brien WD; Topp KA; Sanghvi NT; Zaitsev AV; Hall TJ; Fowlkes JB; Kripfgans OD; Miller JG J Ultrasound Med; 1999 Sep; 18(9):615-31. PubMed ID: 10478971 [TBL] [Abstract][Full Text] [Related]
15. Comparative study of a 15-MHz focused ultrasonic transducer and a 15-MHz unfocused ultrasonic transducer for clinical in-vivo skin-thickness measurements in human subjects. Dick RE; Faddis TN; Barr BG Biomed Instrum Technol; 1992; 26(1):48-51. PubMed ID: 1737184 [TBL] [Abstract][Full Text] [Related]
16. High-frequency backscatter and attenuation measurements of selected bovine tissues between 10 and 30 MHz. Maruvada S; Shung KK; Wang SH Ultrasound Med Biol; 2000 Jul; 26(6):1043-9. PubMed ID: 10996704 [TBL] [Abstract][Full Text] [Related]
17. Acoustical characterization of polysaccharide polymers tissue-mimicking materials. Cuccaro R; Musacchio C; Giuliano Albo PA; Troia A; Lago S Ultrasonics; 2015 Feb; 56():210-9. PubMed ID: 24794507 [TBL] [Abstract][Full Text] [Related]
18. Ultrasound attenuation measurements using a reference phantom with sound speed mismatch. Nam K; Rosado-Mendez IM; Rubert NC; Madsen EL; Zagzebski JA; Hall TJ Ultrason Imaging; 2011 Oct; 33(4):251-63. PubMed ID: 22518955 [TBL] [Abstract][Full Text] [Related]
19. Development of a Tissue-Mimicking Phantom of the Brain for Ultrasonic Studies. Taghizadeh S; Labuda C; Mobley J Ultrasound Med Biol; 2018 Dec; 44(12):2813-2820. PubMed ID: 30274683 [TBL] [Abstract][Full Text] [Related]
20. In vivo ultrasonic attenuation in cetacean soft tissues. Gray MD; Rogers PH J Acoust Soc Am; 2017 Feb; 141(2):EL83. PubMed ID: 28253670 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]