These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

276 related articles for article (PubMed ID: 6688842)

  • 1. In-vitro measurement of static pressure distribution in synovial joints--Part I: Tibial surface of the knee.
    Ahmed AM; Burke DL
    J Biomech Eng; 1983 Aug; 105(3):216-25. PubMed ID: 6688842
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effect of medial meniscectomy and meniscal allograft transplantation on knee and anterior cruciate ligament biomechanics.
    Spang JT; Dang AB; Mazzocca A; Rincon L; Obopilwe E; Beynnon B; Arciero RA
    Arthroscopy; 2010 Feb; 26(2):192-201. PubMed ID: 20141982
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In-vitro measurement of static pressure distribution in synovial joints--Part II: Retropatellar surface.
    Ahmed AM; Burke DL; Yu A
    J Biomech Eng; 1983 Aug; 105(3):226-36. PubMed ID: 6632824
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The role of the meniscus in the anterior-posterior stability of the loaded anterior cruciate-deficient knee. Effects of partial versus total excision.
    Shoemaker SC; Markolf KL
    J Bone Joint Surg Am; 1986 Jan; 68(1):71-9. PubMed ID: 3753605
    [TBL] [Abstract][Full Text] [Related]  

  • 5. In vitro study of contact area and pressure distribution in the human knee after partial and total meniscectomy.
    Ihn JC; Kim SJ; Park IH
    Int Orthop; 1993; 17(4):214-8. PubMed ID: 8407035
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Tibiofemoral loss of contact area but no changes in peak pressures after meniscectomy in a Lapine in vivo quadriceps force transfer model.
    Leumann A; Fortuna R; Leonard T; Valderrabano V; Herzog W
    Knee Surg Sports Traumatol Arthrosc; 2015 Jan; 23(1):65-73. PubMed ID: 25274087
    [TBL] [Abstract][Full Text] [Related]  

  • 7. How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint.
    Haut Donahue TL; Hull ML; Rashid MM; Jacobs CR
    J Biomech; 2003 Jan; 36(1):19-34. PubMed ID: 12485635
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Effects of meniscectomy and transplantation of human knee on stress of tibiofemoral articular surface].
    Wang X; Zhang Y; Hou S; Wu W; Zhang H; Luo D; Gu D; Zhao Y
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2014 Jan; 28(1):21-5. PubMed ID: 24693772
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The effect of medial meniscectomy on strain distribution in the proximal part of the tibia.
    Bourne RB; Finlay JB; Papadopoulos P; Andreae P
    J Bone Joint Surg Am; 1984 Dec; 66(9):1431-7. PubMed ID: 6548753
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Displacement of the medial meniscus within the passive motion characteristics of the human knee joint: an RSA study in human cadaver knees.
    Tienen TG; Buma P; Scholten JG; van Kampen A; Veth RP; Verdonschot N
    Knee Surg Sports Traumatol Arthrosc; 2005 May; 13(4):287-92. PubMed ID: 15309283
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Meniscal Replacement With a Silk Fibroin Scaffold Reduces Contact Stresses in the Human Knee.
    Stein S; Höse S; Warnecke D; Gentilini C; Skaer N; Walker R; Kessler O; Ignatius A; Dürselen L
    J Orthop Res; 2019 Dec; 37(12):2583-2592. PubMed ID: 31403212
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Displacements of the menisci under joint load: an in vitro study in human knees.
    Bylski-Austrow DI; Ciarelli MJ; Kayner DC; Matthews LS; Goldstein SA
    J Biomech; 1994 Apr; 27(4):421-31. PubMed ID: 8188723
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Biomechanical study on contact pressure in the femoro-tibial joint].
    Inaba H
    Nihon Seikeigeka Gakkai Zasshi; 1987 Oct; 61(10):1073-80. PubMed ID: 3437173
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Stabilizing mechanisms of the loaded and unloaded knee joint.
    Hsieh HH; Walker PS
    J Bone Joint Surg Am; 1976 Jan; 58(1):87-93. PubMed ID: 946171
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of lateral meniscal allograft sizing on contact mechanics of the lateral tibial plateau: an experimental study in human cadaveric knee joints.
    Dienst M; Greis PE; Ellis BJ; Bachus KN; Burks RT
    Am J Sports Med; 2007 Jan; 35(1):34-42. PubMed ID: 16923825
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of partial meniscectomy at the medial posterior horn on tibiofemoral contact mechanics and meniscal hoop strains in human knees.
    Seitz AM; Lubomierski A; Friemert B; Ignatius A; Dürselen L
    J Orthop Res; 2012 Jun; 30(6):934-42. PubMed ID: 22072570
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Role of the menisci in the distribution of stress in the knee.
    Radin EL; de Lamotte F; Maquet P
    Clin Orthop Relat Res; 1984 May; (185):290-4. PubMed ID: 6546709
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In vitro load transmission in the canine knee: the effect of medial meniscectomy and varus rotation.
    Anderson DR; Newman AP; Daniels AU
    Knee Surg Sports Traumatol Arthrosc; 1993; 1(1):44-50. PubMed ID: 8535997
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of pre-stresses in the menisci of human knee joint using microindentation.
    Kwak DS; Bae JY; Kim SY; Jeon I; Lu TJ
    Proc Inst Mech Eng H; 2014 Jan; 228(1):11-8. PubMed ID: 24243935
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Influence of partial meniscectomy on attachment forces, superficial strain and contact mechanics in porcine knee joints.
    Freutel M; Seitz AM; Ignatius A; Dürselen L
    Knee Surg Sports Traumatol Arthrosc; 2015 Jan; 23(1):74-82. PubMed ID: 24671386
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.