These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
122 related articles for article (PubMed ID: 6693621)
1. Two-dimensional echocardiographic assessment of complications involving the Ionescu-Shiley pericardial valve in the mitral position. Solana LG; Pechacek LW; DeCastro CM; Klima T; Cooley DA J Am Coll Cardiol; 1984 Feb; 3(2 Pt 1):328-33. PubMed ID: 6693621 [TBL] [Abstract][Full Text] [Related]
2. Fatigue-induced failure of the Ionescu-Shiley pericardial xenograft in the mitral position. In vivo and in vitro correlation and a proposed classification. Gabbay S; Bortolotti U; Wasserman F; Factor S; Strom J; Frater RW J Thorac Cardiovasc Surg; 1984 Jun; 87(6):836-44. PubMed ID: 6727407 [TBL] [Abstract][Full Text] [Related]
4. Non-invasive assessment of the Ionescu-Shiley pericardial xenograft heart valve. Robertson J; Burggraf G Can J Cardiol; 1985; 1(4):241-50. PubMed ID: 3850772 [TBL] [Abstract][Full Text] [Related]
5. Detection of deterioration or infection of homograft and porcine xenograft bioprosthetic valves in mitral and aortic positions by two-dimensional echocardiographic examination. Grenadier E; Sahn DJ; Roche AH; Valdes-Cruz LM; Copeland JG; Goldberg SJ; Allen HD J Am Coll Cardiol; 1983 Sep; 2(3):452-9. PubMed ID: 6875108 [TBL] [Abstract][Full Text] [Related]
6. Pulsed, continuous, and color flow Doppler echocardiographic assessment of normal and abnormal Ionescu-Shiley pericardial valves. Jacobs LE; Parry WR; Kotler MN J Card Surg; 1988 Sep; 3(3 Suppl):429-35. PubMed ID: 2980046 [TBL] [Abstract][Full Text] [Related]
7. Serial Doppler echocardiographic evaluation of Carpentier-Edwards pericardial valve dysfunction: comparison with Ionescu-Shiley valve. Kobayashi Y; Nagata S; Eishi K; Nakano K; Miyatake K Am Heart J; 1998 Jun; 135(6 Pt 1):1086-92. PubMed ID: 9630116 [TBL] [Abstract][Full Text] [Related]
8. Early failures of Ionescu-Shiley bioprosthesis after mitral valve replacement in children. Galioto Fm; Midgley FM; Kapur S; Perry LW; Watson DC; Shapiro SR; Ruckman RN; Scott LP J Thorac Cardiovasc Surg; 1982 Feb; 83(2):306-10. PubMed ID: 7057671 [TBL] [Abstract][Full Text] [Related]
9. Hemodynamic assessment of the Ionescu-Shiley pericardial xenograft in the mitral position. Febres-Roman PR; Haas JM; Cowen GD Cathet Cardiovasc Diagn; 1980; 6(3):233-45. PubMed ID: 7448855 [TBL] [Abstract][Full Text] [Related]
10. Clinical, echocardiographic, and pathologic features of aortic wall dehiscence of porcine bioprosthetic valves: a cause of rapidly progressive mitral regurgitation and heart failure after bioprosthetic mitral valve replacement. Naqvi TZ; Siegel RJ; Buchbinder NA; Fishbein MC J Am Soc Echocardiogr; 1998 Jul; 11(7):720-8. PubMed ID: 9692529 [TBL] [Abstract][Full Text] [Related]
11. Doppler echocardiographic evaluation of Hancock and Björk-Shiley prosthetic values. Sagar KB; Wann LS; Paulsen WH; Romhilt DW J Am Coll Cardiol; 1986 Mar; 7(3):681-7. PubMed ID: 3950245 [TBL] [Abstract][Full Text] [Related]
12. A case of 24 years longevity of an Ionescu-Shiley bioprosthesis in the mitral position. Watanabe Y; Ohkawa S; Yamabuki K; Tsuneoka H; Sugiyama N; Hiyama T Asian Cardiovasc Thorac Ann; 2006 Oct; 14(5):e96-8. PubMed ID: 17005876 [TBL] [Abstract][Full Text] [Related]
14. Two dimensional echocardiographic assessment of patients with bioprosthetic valves. Schapira JN; Martin RP; Fowles RE; Rakowski H; Stinson EB; French JW; Shumway NE; Popp RL Am J Cardiol; 1979 Mar; 43(3):510-9. PubMed ID: 420102 [TBL] [Abstract][Full Text] [Related]
15. Two-dimensional echocardiographic assessment of bioprosthetic valve dysfunction and infective endocarditis. Effron MK; Popp RL J Am Coll Cardiol; 1983 Oct; 2(4):597-606. PubMed ID: 6886226 [TBL] [Abstract][Full Text] [Related]
16. A morphologic study of Carpentier-Edwards pericardial xenografts in the mitral position exhibiting primary tissue failure in adults in comparison with Ionescu-Shiley pericardial xenografts. Machida H; Ishibashi-Ueda H; Nakano K; Sasako Y; Kobayashi J; Bando K; Minatoya K; Imamura H; Kitamura S J Thorac Cardiovasc Surg; 2001 Oct; 122(4):649-55. PubMed ID: 11581594 [TBL] [Abstract][Full Text] [Related]
17. [Diagnosis of dysfunctions of heart valve bioprostheses]. Fedorov BA Kardiologiia; 1987 Jun; 27(6):41-4. PubMed ID: 3626277 [TBL] [Abstract][Full Text] [Related]
18. Early calcific stenosis of aortic and mitral Ionescu-Shiley valves in a patient with bioprosthetic infection. Williams EH; Gonti VR; Nishimura A; Stout LC; Ferrans V J Thorac Cardiovasc Surg; 1981 Sep; 82(3):391-7. PubMed ID: 7278328 [TBL] [Abstract][Full Text] [Related]
19. Early experience with the ionescu-shiley pericardial xenograft valve. Accelerated calcification in children. Walker WE; Duncan JM; Frazier OH; Livesay JJ; Ott DA; Reul GJ; Cooley DA J Thorac Cardiovasc Surg; 1983 Oct; 86(4):570-5. PubMed ID: 6621085 [TBL] [Abstract][Full Text] [Related]
20. Hemolytic anemia following insertion of Ionescu-Shiley mitral valve bioprosthesis. Reddy SB; Pater JL; Pym J; Armstrong PW Can Med Assoc J; 1984 Dec; 131(12):1469-70. PubMed ID: 6498703 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]