120 related articles for article (PubMed ID: 6705358)
1. Silicone implants in dogs. A ten-year histopathologic study.
Swanson AB; Nalbandian RM; Zmugg TJ; Williams D; Jaeger S; Maupin BK; Swanson GD
Clin Orthop Relat Res; 1984 Apr; (184):293-301. PubMed ID: 6705358
[TBL] [Abstract][Full Text] [Related]
2. The susceptibility of smooth implant surfaces to periimplant fibrosis and migration of polyethylene wear debris.
Bobyn JD; Jacobs JJ; Tanzer M; Urban RM; Aribindi R; Sumner DR; Turner TM; Brooks CE
Clin Orthop Relat Res; 1995 Feb; (311):21-39. PubMed ID: 7634577
[TBL] [Abstract][Full Text] [Related]
3. Reconstruction of the canine Achilles and patellar tendons using dacron mesh silicone prosthesis. I. Clinical and biocompatibility evaluation.
Amstutz HC; Coulson WF; David E
J Biomed Mater Res; 1976 Jan; 10(1):47-59. PubMed ID: 129477
[TBL] [Abstract][Full Text] [Related]
4. Long-term silicone implant arthroplasty. Implications of animal and human autopsy findings.
Nalbandian RM; Swanson AB; Maupin BK
JAMA; 1983 Sep; 250(9):1195-8. PubMed ID: 6348328
[TBL] [Abstract][Full Text] [Related]
5. Biocompatibility evaluation of 3 facial silicone elastomers.
França DC; de Castro AL; Soubhia AM; Tucci R; de Aguiar SM; Goiato MC
J Craniofac Surg; 2011 May; 22(3):837-40. PubMed ID: 21558944
[TBL] [Abstract][Full Text] [Related]
6. Soft tissue response of the larynx to silicone, Gore-Tex, and irradiated cartilage implants.
Ustundag E; Boyaci Z; Keskin G; Kaur A; Ozkarakas H
Laryngoscope; 2005 Jun; 115(6):1009-14. PubMed ID: 15933511
[TBL] [Abstract][Full Text] [Related]
7. [Local tissue reactions to subplatysmal implants of cold polymerizing silastic as bladder prostheses in the animal experiment].
Jonas D; Dunzendorfer U; Weber W
Z Exp Chir; 1977 Apr; 10(2):90-5. PubMed ID: 860527
[TBL] [Abstract][Full Text] [Related]
8. [Complications caused by the plastic material used in a 2-stage flexor tendon grafting operation].
Veihelmann D; Schweizer P
Handchirurgie; 1978; 10(4):239-40. PubMed ID: 395037
[TBL] [Abstract][Full Text] [Related]
9. Biocompatibility of Delrin 150: a creep-resistant polymer for total joint prostheses.
Fister JS; Memoli VA; Galante JO; Rostoker W; Urban RM
J Biomed Mater Res; 1985; 19(5):519-33. PubMed ID: 4066726
[TBL] [Abstract][Full Text] [Related]
10. Nasal dorsal augmentation with silicone implants.
Erlich MA; Parhiscar A
Facial Plast Surg; 2003 Nov; 19(4):325-30. PubMed ID: 14737701
[TBL] [Abstract][Full Text] [Related]
11. Study of early sheath development using static nongliding implants.
Hunter JM; Steindel C; Salisbury R; Hughes D
J Biomed Mater Res; 1974; 8(3):155-62. PubMed ID: 4281782
[No Abstract] [Full Text] [Related]
12. Enhanced activity of lysosomal beta-galactosidase after silicone implantation: an experimental study in rats.
Landon BN; Dobke MK; Grzybowski J; Virden CP; Dobak J; Steinsapir ES
J Lab Clin Med; 1993 Jun; 121(6):742-50. PubMed ID: 8505585
[TBL] [Abstract][Full Text] [Related]
13. Thyroplasty using a silicone elastomer implant.
Righi PD; Wilson KM; Gluckman JL
Otolaryngol Clin North Am; 1995 Apr; 28(2):309-16. PubMed ID: 7596611
[TBL] [Abstract][Full Text] [Related]
14. [Macroscopic and microscopic study of local compatibility of silicone rubber in short- and long-term experiments].
Buntrock P; Roggendorf E
Z Exp Chir; 1975; 8(6):356-64. PubMed ID: 802853
[TBL] [Abstract][Full Text] [Related]
15. [Comparative analysis of tissue reaction to acrylic resin materials in studies on Wistar strain rats].
Sobolewska E
Ann Acad Med Stetin; 1999; 45():253-64. PubMed ID: 10909494
[TBL] [Abstract][Full Text] [Related]
16. No effect of hydroxyapatite particles in phagocytosable sizes on implant fixation: an experimental study in dogs.
Rahbek O; Kold S; Bendix K; Overgaard S; Soballe K
J Biomed Mater Res A; 2005 May; 73(2):150-7. PubMed ID: 15754330
[TBL] [Abstract][Full Text] [Related]
17. The relativity of biocompatibility. A critique of the concept of biocompatibility.
Boss JH; Shajrawi I; Aunullah J; Mendes DG
Isr J Med Sci; 1995 Apr; 31(4):203-9. PubMed ID: 7721555
[TBL] [Abstract][Full Text] [Related]
18. Oxidation of silicone elastomer finger joints.
Naidu SH
J Hand Surg Am; 2007 Feb; 32(2):190-3. PubMed ID: 17275593
[TBL] [Abstract][Full Text] [Related]
19. Tissue reaction to prosthetic materials in human temporal bones.
Issa TK; Bahgat MA; Linthicum FH
Am J Otol; 1983 Jul; 5(1):40-3. PubMed ID: 6688328
[TBL] [Abstract][Full Text] [Related]
20. Design and fabrication of two types of artificial tendons for evaluation of surgical techniques.
Wade CW; Ouellette JE; Hodge JW; Urban JJ; Salisbury RE
J Biomed Mater Res; 1975 Jul; 9(4):149-55. PubMed ID: 126245
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]