These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 6713653)

  • 1. Convenient automated method for liquid-chromatographic measurement of glycated hemoglobin.
    Nathan DM; Raskin P
    Clin Chem; 1984 May; 30(5):813-4. PubMed ID: 6713653
    [No Abstract]   [Full Text] [Related]  

  • 2. Assessing the automatic DIAMAT liquid chromatograph for glycated hemoglobins.
    Brenna S; Prencipe L; Montalbetti N; Perlangeli V; Palpon R
    Clin Chem; 1986 May; 32(5):896. PubMed ID: 3698287
    [No Abstract]   [Full Text] [Related]  

  • 3. An automated "high-pressure" liquid-chromatographic assay for hemoglobin A1c.
    Ellis G; Diamandis EP; Giesbrecht EE; Daneman D; Allen LC
    Clin Chem; 1984 Nov; 30(11):1746-52. PubMed ID: 6488517
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of a new automated affinity-chromatographic method for the measurement of glycated hemoglobin.
    Sullivan K; Raskin P
    Diabetes Res Clin Pract; 1991 Aug; 13(1-2):103-6. PubMed ID: 1773707
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Measurement of glycated hemoglobin (HbA1c) with an automated POCT instrument in comparison with HPLC and automated immunochemistry method: evaluation of the influence of hemoglobin variants.
    Haliassos A; Drakopoulos I; Katritsis D; Chiotinis N; Korovesis S; Makris K
    Clin Chem Lab Med; 2006; 44(2):223-7. PubMed ID: 16475912
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Automated determination of glycated hemoglobins with a new high-performance liquid chromatography analyzer.
    Mosca A; Carpinelli A; Bonini P
    Clin Chem; 1986 Jan; 32(1 Pt 1):202-3. PubMed ID: 2416491
    [No Abstract]   [Full Text] [Related]  

  • 7. Determination of glycated hemoglobins in the rat: comparison between two different chromatographic methods and application in experimental diabetology.
    De Tata V; Novelli M; Bombara M; Masiello P; Cappuccio A; Innocenti B; Bergamini E
    Res Exp Med (Berl); 1996; 196(1):9-16. PubMed ID: 8833483
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An automated liquid-chromatographic system for convenient determination of glycated hemoglobin A1c.
    Saleh AK; Moussa MA
    Clin Chem; 1985 Nov; 31(11):1872-6. PubMed ID: 4053357
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A rapid, automated method for glycohemoglobin.
    Demers LM
    Clin Chem; 1993 Feb; 39(2):363. PubMed ID: 8432029
    [No Abstract]   [Full Text] [Related]  

  • 10. Measurement of glycated haemoglobin by boronate-affinity high-pressure liquid chromatography.
    Stirk H; Allen KR
    Ann Clin Biochem; 1999 Mar; 36 ( Pt 2)():233-4. PubMed ID: 10370743
    [No Abstract]   [Full Text] [Related]  

  • 11. Hemoglobin Valme HBB:c.124T>G: a new hemoglobin variant with diminished oxygen affinity causes interference in hemoglobin A1c measurement in an automated ion-exchange HPLC method.
    Benítez IC; Lameiro PC; Ropero P; De la Osa JJ; Fernández FG; Ortiz AM
    Clin Chem Lab Med; 2015 Aug; 53(9):e211-3. PubMed ID: 25781690
    [No Abstract]   [Full Text] [Related]  

  • 12. Comparative evaluation of three assay systems for automated determination of hemoglobin A1c.
    Halwachs-Baumann G; Katzensteiner S; Schnedl W; Pürstner P; Pieber T; Wilders-Truschnig M
    Clin Chem; 1997 Mar; 43(3):511-7. PubMed ID: 9068596
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Chromatographic analysis of glycosylated hemoglobin.
    Bunn HF; McDonald MJ; Cole R; Shapiro R
    Prog Clin Biol Res; 1981; 60():83-94. PubMed ID: 7279971
    [No Abstract]   [Full Text] [Related]  

  • 14. [Abnormal hemoglobin (Hb . Takamatsu) detected in routine determination of glycosylated hemoglobin by HbAIc automated analyzer of high performance liquid chromatography--interference in the hemoglobin AIc fraction].
    Tanaka Y; Suganuma H; Suzuki M; Kanda T; Harano T; Harano K; Ueda S
    Rinsho Byori; 1987 Mar; 35(3):297-302. PubMed ID: 3613146
    [No Abstract]   [Full Text] [Related]  

  • 15. Correlative retention time peak identification method for glycated haemoglobin in high-performance liquid chromatography.
    Ito M; Miura J; Ito M; Umesato F; Yasuda K; Takata Y
    J Chromatogr A; 1994 Feb; 661(1-2):143-51. PubMed ID: 7511027
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Blood glucose and glycated haemoglobin measurement in hospital: which method?
    Pickup JC; Crook MA; Tutt P
    Diabet Med; 1993 Jun; 10(5):402-11. PubMed ID: 8334818
    [No Abstract]   [Full Text] [Related]  

  • 17. Liquid chromatography of glycated hemobglobins with the Daiichi HA-8110 automated analyzer.
    Diamandis EP; Ellis G; Daneman D; Allen LC
    Clin Chem; 1984 Mar; 30(3):503-4. PubMed ID: 6697523
    [No Abstract]   [Full Text] [Related]  

  • 18. Three assays for glycohemoglobin compared.
    Turpeinen U; Karjalainen U; Stenman UH
    Clin Chem; 1995 Feb; 41(2):191-5. PubMed ID: 7874770
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Determination of glycosylated hemoglobin HbA1c by liquid phase chromatography].
    Guyon F; Potier M; Coignet MC
    Ann Biol Clin (Paris); 1988; 46(2):116-8. PubMed ID: 3382061
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Robotic chromatography: development and evaluation of automated instrumentation for assay of glycohemoglobin.
    Herold CD; Andree K; Herold DA; Felder RA
    Clin Chem; 1993 Jan; 39(1):143-7. PubMed ID: 8419040
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.