These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

256 related articles for article (PubMed ID: 6724912)

  • 1. A high sensitivity LiF thermoluminescent dosimeter--LiF(Mg, Cu, P).
    Wu DK; Sun FY; Dai HC
    Health Phys; 1984 May; 46(5):1063-7. PubMed ID: 6724912
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Synchrotron radiation in the study of the variation of dose response in thermoluminescence dosimeters with radiation energy.
    Kron T; Smith A; Hyodo K
    Australas Phys Eng Sci Med; 1996 Dec; 19(4):225-36. PubMed ID: 9060209
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of effectiveness of thermoluminescent crystals LiF:Mg,Ti, and LiF:Mg,Cu,P for clinical dosimetry.
    Harris CK; Elson HR; Lamba MA; Foster AE
    Med Phys; 1997 Sep; 24(9):1527-9. PubMed ID: 9304583
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The application of LiF:Mg,Cu,P to large scale personnel dosimetry: current status and future directions.
    Moscovitch M; St John TJ; Cassata JR; Blake PK; Rotunda JE; Ramlo M; Velbeck KJ; Luo LZ
    Radiat Prot Dosimetry; 2006; 119(1-4):248-54. PubMed ID: 16835277
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A personal thermoluminescence dosimeter using LiF:Mg,Cu,Na,Si detectors for photon fields.
    Jung H; Lee KJ; Kim JL
    Appl Radiat Isot; 2003 Jul; 59(1):87-93. PubMed ID: 12878128
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Type testing of a locally made LiF:Mg,Ti + PTFE TLD for its use as a personal dosimeter.
    Azorín J; Torijano E; Azorín C
    Appl Radiat Isot; 2018 Nov; 141():246-249. PubMed ID: 29843989
    [TBL] [Abstract][Full Text] [Related]  

  • 7. DOSIMETRIC CHARACTERISTICS OF THE NOVEL LiF:Mg,Cu,Ag PHOSPHOR.
    Yahyaabadi A; Torkzadeh F; Rezaei-Ochbelagh D
    Radiat Prot Dosimetry; 2018 Mar; 178(4):359-363. PubMed ID: 28981803
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A new high sensitivity thermoluminescent phosphor with low residual signal and good stability to heat treatment: LiF:Mg,Cu,Na,Si.
    Tang K; Zhu H; Shen W; Liu B
    Radiat Prot Dosimetry; 2002; 100(1-4):239-42. PubMed ID: 12382868
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Variations in dose response with x-ray energy of LiF:Mg,Cu,P thermoluminescence dosimeters: implications for clinical dosimetry.
    Duggan L; Hood C; Warren-Forward H; Haque M; Kron T
    Phys Med Biol; 2004 Sep; 49(17):3831-45. PubMed ID: 15470908
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A comparative study on the susceptibility of LiF:Mg,Ti (TLD-100) and LiF:Mg,Cu,P (TLD-100H) to spurious signals in thermoluminescence dosimetry.
    Al-Haj A; Lagarde C; Mahyoub F
    Radiat Prot Dosimetry; 2007; 125(1-4):399-402. PubMed ID: 17223633
    [TBL] [Abstract][Full Text] [Related]  

  • 11. UV-induced bleaching of deep traps in Harshaw TLD LiF:Mg,Cu,P and LiF:Mg,Ti.
    Benevides L; Voss S; Nita I; Rotunda J; Velbeck K; Luo LZ; Moscovitch M
    Radiat Prot Dosimetry; 2011 Mar; 144(1-4):199-201. PubMed ID: 21310735
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Further studies on the role of dopants in LiF:Mg,Cu,Si thermoluminescent material.
    Tang K; Fan H; Cui H; Zhu H; Liu Z
    Radiat Prot Dosimetry; 2015 Feb; 163(3):288-91. PubMed ID: 24966341
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Energy response of a thermoluminescent lithium fluoride disc dosimeter to beta-rays.
    Ogawa Y; Kimura Y; Honda Y
    Radioisotopes; 1985 Mar; 34(3):131-6. PubMed ID: 4011959
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pre- and post-irradiation fading effect for LiF:Mg,Ti and LiF:Mg,Cu,P materials used in routine monitoring.
    Carinou E; Askounis P; Dimitropoulou F; Kiranos G; Kyrgiakou H; Nirgianaki E; Papadomarkaki E; Kamenopoulou V
    Radiat Prot Dosimetry; 2011 Mar; 144(1-4):207-10. PubMed ID: 21199822
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Role of impurities in the thermoluminescence of LiF:Mg,Cu,P.
    Chen TC; Stoebe TG
    Radiat Prot Dosimetry; 2002; 100(1-4):243-6. PubMed ID: 12382869
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The low energy X-ray response of the LiF:Mg:Cu:P thermoluminescent dosemeter: a comparison with LiF:Mg:Ti.
    Edwards CR; Mountford PJ; Green S; Palethorpe JE; Moloney AJ
    Br J Radiol; 2005 Jun; 78(930):543-7. PubMed ID: 15900061
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of the TL responses of two different preparations of LiF:Mg,Cu,P irradiated by photons of various energies.
    González PR; Furetta C; Azorín J
    Appl Radiat Isot; 2007 Mar; 65(3):341-4. PubMed ID: 17085055
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparative studies on radioluminescent and thermoluminescent spectra of LiF:Mg,Cu,P and LiF:Mg,Cu,Si.
    Tang K; Fan H; Cui H; Zhu H; Liu Z
    Radiat Prot Dosimetry; 2016 Mar; 168(4):459-64. PubMed ID: 26264711
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Developments in the synthesis of LiF:Mg,Cu,Na,Si TL material.
    Lee JI; Kim JL; Chang SY; Chung KS; Choe HS
    Radiat Prot Dosimetry; 2004; 108(1):79-83. PubMed ID: 14974608
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Energy response of different types of RADOS personal dosemeters with MTS-N (LiF:Mg,Ti) and MCP-N (LiF:Mg,Cu,P) TL detectors.
    Obryk B; Hranitzky C; Stadtmann H; Budzanowski M; Olko P
    Radiat Prot Dosimetry; 2011 Mar; 144(1-4):211-4. PubMed ID: 21227957
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.