These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
70 related articles for article (PubMed ID: 6726441)
1. Use of a copper filter for dose-calibrator measurements of nuclides emitting K x-rays. Wiarda KS J Nucl Med; 1984 May; 25(5):633-4. PubMed ID: 6726441 [No Abstract] [Full Text] [Related]
2. Dose calibrator assay of iodine-123 and indium-111 with a copper filter. Kowalsky RJ; Johnston RE J Nucl Med Technol; 1998 Jun; 26(2):94-8. PubMed ID: 9604830 [TBL] [Abstract][Full Text] [Related]
3. Accurate measurement of copper-67 in the presence of copper-64 contaminant using a dose calibrator. DeNardo GL; Kukis DL; Shen S; DeNardo SJ J Nucl Med; 1996 Feb; 37(2):302-6. PubMed ID: 8667066 [TBL] [Abstract][Full Text] [Related]
4. Radioassay of yttrium-90 radiation using the radionuclide dose calibrator. Salako QA; DeNardo SJ J Nucl Med; 1997 May; 38(5):723-6. PubMed ID: 9170436 [TBL] [Abstract][Full Text] [Related]
5. Development of a correction factor for Xe-133 vials for use with a dose calibrator. Gels GL; Piltingsrud HV J Nucl Med; 1982 Apr; 23(4):357-9. PubMed ID: 7069499 [TBL] [Abstract][Full Text] [Related]
6. A new experimental determination of the dose calibrator setting for 188Re. Zimmerman BE; Cessna JT; Unterweger MP; Li AN; Whiting JS; Knapp FF J Nucl Med; 1999 Sep; 40(9):1508-16. PubMed ID: 10492373 [TBL] [Abstract][Full Text] [Related]
7. Increased resolving power from scintillation cameras using electronic signal processing and a movable filter plate. Jaszczak RJ J Nucl Med; 1973 Jan; 14(1):14-20. PubMed ID: 4682147 [No Abstract] [Full Text] [Related]
9. [The properties of multichannel collimators for the use in scintigraphy]. Husák V; Wiedermann M; Kleinbauer K Radiobiol Radiother (Berl); 1966; 7(3):373-82. PubMed ID: 5923948 [No Abstract] [Full Text] [Related]
10. Calibration of a radionuclide calibrator system as a Bulgarian standard for activity. Schrader H; Kossert K; Mintcheva J Appl Radiat Isot; 2008; 66(6-7):965-71. PubMed ID: 18396053 [TBL] [Abstract][Full Text] [Related]
11. Methods for calculating the deadtime of Anger camera systems. Adams R; Zimmerman D J Nucl Med; 1973 Jul; 14(7):496-8. PubMed ID: 4711265 [No Abstract] [Full Text] [Related]
12. [Tools for metrological support in measurements of the characteristics of devices for radionuclide diagnosis]. Sichkar' GA Med Tekh; 1993; (4):12-7. PubMed ID: 8277833 [TBL] [Abstract][Full Text] [Related]
14. Sideband transmission in interference filters and its implications for measurements of spectral sensitivity. Hawryshyn CW Exp Biol; 1989; 48(2):123-6. PubMed ID: 2920811 [TBL] [Abstract][Full Text] [Related]
15. Effects of radiation quality on the calibration of kerma-area product meters in x-ray beams. Toroi P; Komppa T; Kosunen A; Tapiovaara M Phys Med Biol; 2008 Sep; 53(18):5207-21. PubMed ID: 18728309 [TBL] [Abstract][Full Text] [Related]
16. Solutions to problems in dose calibrator assay of iodine-123. Harris CC; Jaszczak RJ; Greer KL; Briner WH; Coleman RE Am J Physiol Imaging; 1988; 3(1):33-5. PubMed ID: 3390353 [No Abstract] [Full Text] [Related]
17. Experimental determination of calibration settings of a commercially available radionuclide calibrator for various clinical measurement geometries and radionuclides. Ceccatelli A; Benassi M; D'Andrea M; De Felice P; Fazio A; Nocentini S; Strigari L Appl Radiat Isot; 2007 Jan; 65(1):120-5. PubMed ID: 16996744 [TBL] [Abstract][Full Text] [Related]
18. Quantitation of iodine-124 contamination in iodine-123 radiopharmaceuticals: characterization of a second dose calibrator. Palmer DW; Rao SA J Nucl Med; 1988 Jul; 29(7):1302. PubMed ID: 3392589 [No Abstract] [Full Text] [Related]
19. Monte Carlo calculations of calibration and geometry correction factors of a radionuclide calibrator. Olsovcová V; Havelka M Appl Radiat Isot; 2006; 64(10-11):1370-4. PubMed ID: 16546399 [TBL] [Abstract][Full Text] [Related]
20. Determination of the efficiency of commercially available dose calibrators for beta-emitters. Valley JF; Bulling S; Leresche M; Wastiel C J Nucl Med Technol; 2003 Mar; 31(1):27-32. PubMed ID: 12624125 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]