These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 6731131)

  • 1. A measuring device to determine a universal parameter for the flow characteristics of blood: measurement of the yield shear stress in a branched capillary.
    Radtke H; Schneider R; Witt R; Kiesewetter H; Schmid-Schönbein H
    Adv Exp Med Biol; 1984; 169():851-7. PubMed ID: 6731131
    [No Abstract]   [Full Text] [Related]  

  • 2. The influence of erythrocyte shape and rigidity on the viscosity of blood.
    Whitmore RL
    Biorheology; 1981; 18(3-6):557-62. PubMed ID: 7326393
    [No Abstract]   [Full Text] [Related]  

  • 3. Blood flow in capillary tubes: curvature and gravity effects.
    Hung TC; Hung TK; Bugliarello G
    Biorheology; 1980; 17(4):331-42. PubMed ID: 7260345
    [No Abstract]   [Full Text] [Related]  

  • 4. Maxwell fluid behavior of blood at low shear rate.
    McMillan DE; Utterback N
    Biorheology; 1980; 17(4):343-54. PubMed ID: 7260346
    [No Abstract]   [Full Text] [Related]  

  • 5. Time-dependent rheological behavior of blood at low shear in narrow vertical tubes.
    Alonso C; Pries AR; Gaehtgens P
    Am J Physiol; 1993 Aug; 265(2 Pt 2):H553-61. PubMed ID: 8368359
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Thixotropy of blood and red blood cell suspensions.
    McMillan DE; Utterback NG; Baldridge JB
    Biorheology; 1980; 17(5-6):445-54. PubMed ID: 7306695
    [No Abstract]   [Full Text] [Related]  

  • 7. Model studies on phase separation at a capillary orifice.
    Pries AR; Albrecht KH; Gaehtgens P
    Biorheology; 1981; 18(3-6):355-67. PubMed ID: 7326381
    [No Abstract]   [Full Text] [Related]  

  • 8. Obtaining the shear stress versus shear rate relationship and yield stress of blood from capillary viscometry data by Tikhonov regularization.
    Yeow YL; Leong YK; Wickramasinghe SR; Han B
    Biotechnol Prog; 2002; 18(4):879-84. PubMed ID: 12153325
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The measurement of density and its significance in blood rheology.
    Chmiel H; Anadere I; Walitza E; Witte S
    Biorheology; 1983; 20(5):685-96. PubMed ID: 6677286
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Contribution of erythrocytes to turbulent blood flow.
    Stein PD; Sabbah HN; Blick EF
    Biorheology; 1975 Aug; 12(5):293-9. PubMed ID: 1203532
    [No Abstract]   [Full Text] [Related]  

  • 11. Dependence of capillary flow resistance upon the width of the marginal layer and the viscosity of the axial core.
    Braasch D
    Biorheology Suppl; 1984; 1():135-43. PubMed ID: 6591966
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effect of the endothelial-cell glycocalyx on the motion of red blood cells through capillaries.
    Damiano ER
    Microvasc Res; 1998 Jan; 55(1):77-91. PubMed ID: 9473411
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Rheological modelling of fresh blood from transient pressure measurements.
    Yepsen G; Boutin D; Litt M; Kron RE
    Biorheology; 1981; 18(3-6):475-84. PubMed ID: 7326388
    [No Abstract]   [Full Text] [Related]  

  • 14. Comparative interest of two coaxial viscometers: ecktacytometer and low shear 30.
    Adjizian JC; Droulle C; Osterman G; Pignon B; Potron G
    Biorheology Suppl; 1984; 1():95-7. PubMed ID: 6592005
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Turbulent blood flow and the effects of erythrocytes.
    Munter WA; Stein PD
    Cardiovasc Res; 1974 May; 8(3):338-46. PubMed ID: 4416756
    [No Abstract]   [Full Text] [Related]  

  • 16. Plasma viscosity regulates capillary perfusion during extreme hemodilution in hamster skinfold model.
    Tsai AG; Friesenecker B; McCarthy M; Sakai H; Intaglietta M
    Am J Physiol; 1998 Dec; 275(6):H2170-80. PubMed ID: 9843817
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Determination of yield point: methods and review.
    Kiesewetter H; Radtke H; Jung F; Schmid-Schönbein H; Wortberg G
    Biorheology; 1982; 19(1/2):363-74. PubMed ID: 7093463
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Rheogoniometric studies of whole human blood at shear rates down to 0.0009 sec-1. II. Mathematical interpretation.
    Huang CR; King RG; Copley AL
    Biorheology; 1973 Mar; 10(1):23-8. PubMed ID: 4724174
    [No Abstract]   [Full Text] [Related]  

  • 19. Poiseuille flow of micropolar fluid with non-zero couple stress at boundary with applications to blood flow.
    Chaturani P; Mahajan SP
    Biorheology; 1982; 19(4):507-18. PubMed ID: 7126803
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The erythrocyte-stasis-meter (ESM): a device to determine a universal parameter for the flow characteristics of blood.
    Radtke H; Roggenkamp HG; Wolf S; Mrowietz C; Kiesewetter H
    Biorheology Suppl; 1984; 1():75-7. PubMed ID: 6236858
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.