These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

177 related articles for article (PubMed ID: 6736063)

  • 1. In-vitro wall shear measurements at aortic valve prostheses.
    Tillmann W; Reul H; Herold M; Bruss KH; van Gilse J
    J Biomech; 1984; 17(4):263-79. PubMed ID: 6736063
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Two-dimensional color-mapping of turbulent shear stress distribution downstream of two aortic bioprosthetic valves in vitro.
    Nygaard H; Giersiepen M; Hasenkam JM; Reul H; Paulsen PK; Rovsing PE; Westphal D
    J Biomech; 1992 Apr; 25(4):429-40. PubMed ID: 1583021
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Turbulent stress measurements downstream of six mechanical aortic valves in a pulsatile flow model.
    Hasenkam JM; Nygaard H; Giersiepen M; Reul H; Stødkilde-Jørgensen H
    J Biomech; 1988; 21(8):631-45. PubMed ID: 3170618
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Laser anemometry measurements of steady flow past aortic valve prostheses.
    Chew YT; Low HT; Lee CN; Kwa SS
    J Biomech Eng; 1993 Aug; 115(3):290-8. PubMed ID: 8231145
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Current status of the Beall, Bjork-Shiley, Braunwald-Cutter, Lillehei-Kaster and Smeloff-Cutter cardiac valve prostheses.
    Brawley RK; Donahoo JS; Gott VL
    Am J Cardiol; 1975 Jun; 35(6):855-65. PubMed ID: 124127
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Velocity and shear stress distribution downstream of mechanical heart valves in pulsatile flow.
    Giersiepen M; Krause U; Knott E; Reul H; Rau G
    Int J Artif Organs; 1989 Apr; 12(4):261-9. PubMed ID: 2722280
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Three-dimensional visualization of velocity fields downstream of six mechanical aortic valves in a pulsatile flow model.
    Hasenkam JM; Giersiepen M; Reul H
    J Biomech; 1988; 21(8):647-61. PubMed ID: 3170619
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In vitro stress measurements in the vicinity of six mechanical aortic valves using hot-film anemometry in steady flow.
    Hasenkam JM; Westphal D; Nygaard H; Reul H; Giersiepen M; Stødkilde-Jørgensen H
    J Biomech; 1988; 21(3):235-47. PubMed ID: 2967827
    [TBL] [Abstract][Full Text] [Related]  

  • 9. In vitro velocity and turbulence measurements in the vicinity of three new mechanical aortic heart valve prostheses: Björk-Shiley Monostrut, Omni-Carbon, and Duromedics.
    Yoganathan AP; Sung HW; Woo YR; Jones M
    J Thorac Cardiovasc Surg; 1988 May; 95(5):929-39. PubMed ID: 3361941
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Bileaflet, tilting disc and porcine aortic valve substitutes: in vitro hydrodynamic characteristics.
    Yoganathan AP; Chaux A; Gray RJ; Woo YR; DeRobertis M; Williams FP; Matloff JM
    J Am Coll Cardiol; 1984 Feb; 3(2 Pt 1):313-20. PubMed ID: 6693619
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Advances in prosthetic heart valves: fluid mechanics of aortic valve designs.
    Yoganathan AP; Woo YR; Sung HW; Jones M
    J Biomater Appl; 1988 Apr; 2(4):579-614. PubMed ID: 2974076
    [TBL] [Abstract][Full Text] [Related]  

  • 12. In vitro pulsatile flow hemodynamics of five mechanical aortic heart valve prostheses.
    Walker PG; Yoganathan AP
    Eur J Cardiothorac Surg; 1992; 6 Suppl 1():S113-23. PubMed ID: 1389270
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In vitro pulsatile flow velocity and turbulent shear stress measurements in the vicinity of mechanical aortic heart valve prostheses.
    Woo YR; Yoganathan AP
    Life Support Syst; 1985; 3(4):283-312. PubMed ID: 4068753
    [TBL] [Abstract][Full Text] [Related]  

  • 14. On the hemolytic and thrombogenic potential of occluder prosthetic heart valves from in-vitro measurements.
    Figliola RS; Mueller TJ
    J Biomech Eng; 1981 May; 103(2):83-90. PubMed ID: 7278187
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Doppler hemodynamic evaluation of prosthetic (Starr-Edwards and Björk-Shiley) and bioprosthetic (Hancock and Carpentier-Edwards) cardiac valves.
    Williams GA; Labovitz AJ
    Am J Cardiol; 1985 Aug; 56(4):325-32. PubMed ID: 4025173
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Instantaneous blood flow velocity profiles before and after aortic valve replacement (author's transl)].
    Meisner H; Hagl S; Heimisch W; Gams E; Erben R; Struck E; Schmidt-Habelmann P; Sebening F
    Thoraxchir Vask Chir; 1975 Jun; 23(3):282-90. PubMed ID: 1080605
    [TBL] [Abstract][Full Text] [Related]  

  • 17. In vitro flow dynamics of four prosthetic aortic valves: a comparative analysis.
    Hanle DD; Harrison EC; Yoganathan AP; Allen DT; Corcoran WH
    J Biomech; 1989; 22(6-7):597-607. PubMed ID: 2808443
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In vitro fluid dynamic characteristics of the Medtronic-Hall pivoting disc heart valve prosthesis.
    Yoganathan AP; Stevenson DM; Williams FP; Woo YR; Franch RH; Harrison EC
    Scand J Thorac Cardiovasc Surg; 1982; 16(3):235-43. PubMed ID: 6221405
    [TBL] [Abstract][Full Text] [Related]  

  • 19. In vitro pulsatile flow measurements in the vicinity of mechanical heart valves in the mitral flow chamber.
    Woo YR; Yoganathan AP
    Life Support Syst; 1986; 4(2):115-39. PubMed ID: 2943945
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Relation of maximal opening of disk valves to characteristics of aortic blood flow.
    Sabbah HN; Stein PD
    J Biomech Eng; 1980 May; 102(2):147-50. PubMed ID: 7412237
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]