BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

87 related articles for article (PubMed ID: 6736086)

  • 1. The effect of early weight-bearing on the stability of femoral neck fractures treated with Knowles pins.
    Arnold WD
    J Bone Joint Surg Am; 1984 Jul; 66(6):847-52. PubMed ID: 6736086
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Verified causes of failure in the treatment of femoral neck fractures with multiple Knowles pins.
    Di Muria GV; Marcucci M; Pitto RP; Troiani M
    Ital J Orthop Traumatol; 1991 Mar; 17(1):107-16. PubMed ID: 1894506
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Knowles pinning of experimental femoral neck fractures: biomechanical study.
    Rubin R; Trent P; Arnold W; Burstein A
    J Trauma; 1981 Dec; 21(12):1036-9. PubMed ID: 7321065
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Femoral neck fractures. 121 cases treated by Knowles pinning.
    Shih CH; Wang KC
    Clin Orthop Relat Res; 1991 Oct; (271):195-200. PubMed ID: 1914295
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Treatment of femoral neck fractures with a sliding compression screw and two Knowles pins.
    Ort PJ; LaMont J
    Clin Orthop Relat Res; 1984 Nov; (190):158-62. PubMed ID: 6488626
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Internal fixation of femoral neck fractures. A comparative biomechanical study of Knowles pins and 6.5-mm cancellous screws.
    Springer ER; Lachiewicz PF; Gilbert JA
    Clin Orthop Relat Res; 1991 Jun; (267):85-92. PubMed ID: 2044298
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Crossed pins vs parallel pins in the treatment of femoral neck fractures.
    Gebuhr P; Hovgaard C; Petersen JR
    Orthopedics; 1991 Aug; 14(8):908-9. PubMed ID: 1923973
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Clinical study on internal fixation of femoral neck fractures.
    Martens M; Van Audekercke R; Mulier JC; Stuyck J
    Clin Orthop Relat Res; 1979 Jun; (141):199-202. PubMed ID: 477106
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Breakage of Knowles pins used for femoral neck fractures.
    Lozano Requena JA; Bas Hermida T; Perez Belmonte C; Llabres AJ; Baixauli F
    Int Orthop; 1993 Dec; 17(6):365-6. PubMed ID: 8163311
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of fixation in the treatment of femoral neck fractures.
    McCutchen JW; Carnesale PG
    Clin Orthop Relat Res; 1982; (171):44-50. PubMed ID: 7140085
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Stability of femoral neck fracture. Roentgen stereophotogrammetry of 29 hook-pinned fractures.
    Ragnarsson JI; Kärrholm J
    Acta Orthop Scand; 1991 Jun; 62(3):201-7. PubMed ID: 2042460
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Early fixation failure in displaced femoral neck fractures.
    Stappaerts KH
    Arch Orthop Trauma Surg (1978); 1985; 104(5):314-8. PubMed ID: 4091638
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In the treatment of medial fractures of the neck of the femur. Osteosynthesis with modified Knowles pins.
    Pitto E; Giusti E; Santini A
    Acta Orthop Belg; 1980; 46(2):117-29. PubMed ID: 7457107
    [No Abstract]   [Full Text] [Related]  

  • 14. Internal fixation of femoral neck fractures. A follow-up study of 118 cases.
    Stappaerts KH; Broos PL
    Acta Chir Belg; 1987; 87(4):247-51. PubMed ID: 3661004
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Reasonably good results of Hansson's pins in elderly patients with a medial femoral neck fracture].
    van Meeteren MC; de Vries LS; Hammacher ER; van der Werken C
    Ned Tijdschr Geneeskd; 1996 Jul; 140(30):1552-7. PubMed ID: 8765764
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Function after hook-pin fixation of femoral neck fractures. Prospective 2-year follow-up of 191 cases.
    Nilsson LT; Strömqvist B; Thorngren KG
    Acta Orthop Scand; 1989 Oct; 60(5):573-8. PubMed ID: 2603659
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A comparison of modified Knowles pins and cannulated cancellous screws for the treatment of nondisplaced or impacted femoral neck fractures.
    Jarolem KL; Koval KJ; Zuckerman JD; Aharonoff G
    Bull Hosp Jt Dis; 1993; 53(3):11-4. PubMed ID: 8012260
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A biomechanical study of two methods of internal fixation of unstable fractures of the femoral neck. A preliminary study.
    Goodman SB; Davidson JA; Locke L; Novotny S; Jones H; Csongradi JJ
    J Orthop Trauma; 1992; 6(1):66-72. PubMed ID: 1556626
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Percutaneous Neufeld pinning for femoral neck fractures.
    Swiontkowski MF; Hansen ST
    Clin Orthop Relat Res; 1986 May; (206):113-6. PubMed ID: 3708963
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Stress fractures of the femoral neck following strenuous activity.
    Volpin G; Hoerer D; Groisman G; Zaltzman S; Stein H
    J Orthop Trauma; 1990; 4(4):394-8. PubMed ID: 2266444
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]