These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 6742392)

  • 1. Accumulation of thymol in halothane vaporizers.
    Rosenberg PH; Alila A
    Anaesthesia; 1984 Jun; 39(6):581-3. PubMed ID: 6742392
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dependence of the output of a halothane vaporizer on thymol concentration.
    Gray WM
    Anaesthesia; 1988 Dec; 43(12):1047-9. PubMed ID: 3232783
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Long-term performance of Tec vaporizers. Basis for a rational maintenance policy.
    Carter KB; Gray WM; Railton R; Richardson W
    Anaesthesia; 1988 Dec; 43(12):1042-6. PubMed ID: 3232782
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An evaluation of gas density dependence of anaesthetic vaporizers.
    Prins L; Strupat J; Clement J; Knill RL
    Can Anaesth Soc J; 1980 Mar; 27(2):106-10. PubMed ID: 6767537
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of nitrous oxide on the output of three halothane vaporizers.
    Synnott A; Wren WS
    Br J Anaesth; 1986 Sep; 58(9):1055-8. PubMed ID: 3756052
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Vaporizer malfunction--a cause of high concentration halothane vapor delivery].
    Yamada T; Masuda J; Takeda J; Sekiguchi H; Fukushima K
    Masui; 1994 Mar; 43(3):421-5. PubMed ID: 8182893
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The influence of carrier gas on the output of automatic plenum vaporizers.
    Diaz PM
    Br J Anaesth; 1976 Apr; 48(4):387-91. PubMed ID: 1276004
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [A research on misfilling of inhalation anesthetics into vaporizers].
    Kumazawa T; Kashimoto S; Tanaka Y; Manabe M; Takashima S; Kinoshita H; Yamamoto I
    Masui; 1984 Aug; 33(8):882-8. PubMed ID: 6512960
    [No Abstract]   [Full Text] [Related]  

  • 9. Administration of halothane in the 0-0.5 per cent concentration range with the Fluotec Mark 2 and Mark 3 vaporizers.
    Latto IP
    Br J Anaesth; 1973 Jun; 45(6):563-9. PubMed ID: 4718247
    [No Abstract]   [Full Text] [Related]  

  • 10. The effect of nitrous oxide on halothane output from Fluotec Mark 2 vaporizers.
    Stoelting RK
    Anesthesiology; 1971 Aug; 35(2):215-8. PubMed ID: 5568139
    [No Abstract]   [Full Text] [Related]  

  • 11. The influence of pressure swings on the output of plenum vaporizers.
    Burm AG; Jorritsma FF; van Bijnen AW
    Anaesthesist; 1982 May; 31(5):257-61. PubMed ID: 7048993
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of various carrier gases on the halothane output of the Fluotec Mark 3 vaporizer.
    Haskins SC; Knapp RG
    Am J Vet Res; 1980 Jan; 41(1):153-4. PubMed ID: 7189100
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Pumping effect of the Philips AVI ventilator on Fluotec vaporizers.
    Mackenzie N; Grant IS
    Br J Anaesth; 1983 Sep; 55(9):921-2. PubMed ID: 6577905
    [No Abstract]   [Full Text] [Related]  

  • 14. Free-standing vaporizers. Another hazard.
    Kelly DA
    Anaesthesia; 1985 Jul; 40(7):661-3. PubMed ID: 4025770
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Service improves performance of unattended draw-over halothane vaporizers.
    Hansen D
    Trop Doct; 2001 Jan; 31(1):29-31. PubMed ID: 11205598
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A laboratory comparison of Copper Kettle, Fluotec Mark 2, and Pentec vaporizers.
    Gartner J; Stoelting RK
    Anesth Analg; 1974; 53(2):187-90. PubMed ID: 4150154
    [No Abstract]   [Full Text] [Related]  

  • 17. [Accuracy of halothane vaporizers with respect to temperature, carrier gas composition and gas flow rate].
    Rieke H; Raffauf EM; Züchner K; Hauschke D; Sonntag H
    Anaesthesist; 1985 Oct; 34(10):522-7. PubMed ID: 4073446
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Concentration measurements on the Fluotec and Halothane-Vapor vaporizers in the hyperbaric chamber].
    Weis KH; Schreiber P
    Anaesthesist; 1967 Dec; 16(12):357-9. PubMed ID: 5241418
    [No Abstract]   [Full Text] [Related]  

  • 19. Accuracy of 94 anaesthetic agent vaporizers in clinical use.
    Nielsen J; Pedersen FM; Knudsen F; Jensen MB; Ibsen M
    Br J Anaesth; 1993 Sep; 71(3):453-7. PubMed ID: 8398533
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Consequences of misfilling contemporary vaporizers with desflurane.
    Andrews JJ; Johnston RV; Kramer GC
    Can J Anaesth; 1993 Jan; 40(1):71-6. PubMed ID: 8425247
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.