These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

211 related articles for article (PubMed ID: 6743873)

  • 1. [Reliability of the transcutaneous PO2 measurement in the adult by the TCM 1 radiometer electrode].
    Ordronneau J; Chailleux E; Gaucher L; Ginet JD; Moigneteau C
    Bull Eur Physiopathol Respir; 1984; 20(3):303-6. PubMed ID: 6743873
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Transcutaneous oxygen tension measurement I. Age variation and reproducibility.
    Gøthgen J; Jacobsen E
    Acta Anaesthesiol Scand Suppl; 1978; 67():66-70. PubMed ID: 278457
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Comparison of arterial and transcutaneous oxygen partial pressure in infants with bronchopulmonary dysplasia].
    Praud JP; Dreizzen E; Carofilis A; Magny JF; Saby MA; Dehan M; Gabilan JC; Gaultier C
    Arch Fr Pediatr; 1988 Oct; 45(8):537-40. PubMed ID: 3214246
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Continuous comparison of in vitro and in vivo calibrated transcutaneous oxygen tension with arterial oxygen tension in infants.
    Pollitzer MJ; Reynolds EO; Morgan AK; Soutter LP; Parker D; Delpy DT; Whitehead MD
    Birth Defects Orig Artic Ser; 1979; 15(4):295-304. PubMed ID: 534709
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Reliability of transcutaneous PO2 measurements and ear oximetry at different levels of exercise].
    Chailleux E; Caby I; Hervouet A; Ordronneau J; Chollet S
    Rev Mal Respir; 1989; 6(3):229-35. PubMed ID: 2740587
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Use of transcutaneous oxygen and carbon dioxide tensions for assessing indices of gas exchange during exercise testing.
    Carter R; Banham SW
    Respir Med; 2000 Apr; 94(4):350-5. PubMed ID: 10845433
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Correlation of hemodynamic variables with transcutaneous PO2 measurements in critically ill adult patients.
    Reed RL; Maier RV; Landicho D; Kenny MA; Carrico CJ
    J Trauma; 1985 Nov; 25(11):1045-53. PubMed ID: 4057292
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Transcutaneous oxygen tension measurement II. The influence of halothane and hypotension.
    Gøthgen I; Jacobsen E
    Acta Anaesthesiol Scand Suppl; 1978; 67():71-5. PubMed ID: 278458
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Interpretation of the tcPO2 curve in adult patients in an intensive care unit.
    Rooth G; Hedstrand U; Ogren C
    Birth Defects Orig Artic Ser; 1979; 15(4):557-71. PubMed ID: 534740
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Continuous transcutaneous blood gas monitoring during fiberbronchoscopy].
    Emslander HP; Schlehe H; Reimann HJ; Daum S
    Schweiz Med Wochenschr; 1983 Jan; 113(3):114-6. PubMed ID: 6187066
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Correlation of arterial and transcutaneous po2s following wet and dry calibration techniques: a comparison study.
    McDowell JW
    Respir Care; 1981 Jul; 26(7):649-52. PubMed ID: 10315131
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Feasibility of cutaneous blood gas monitoring during exercise stress testing.
    Kentala E; Repo UK
    Ann Clin Res; 1984; 16(1):40-6. PubMed ID: 6430206
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Transcutaneous pO2 electrode.
    Vesterager P
    Scand J Clin Lab Invest Suppl; 1977; 146():27-30. PubMed ID: 834956
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The influence of different electrode temperatures on the recorded transcutaneous Po2 level.
    Löfgren O; Jacobson L
    Pediatrics; 1979 Dec; 64(6):892-7. PubMed ID: 514717
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Transcutaneous measurement of pO2.(author's transl)].
    Dautzenberg B; Carter H; Sors C
    Rev Fr Mal Respir; 1981; 9(4):327-35. PubMed ID: 7302351
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Use of the continuous transcutaneous PO2 measurement in lung function tests.
    Goeckenjan G; strasser K
    Birth Defects Orig Artic Ser; 1979; 15(4):531-9. PubMed ID: 534737
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Transcutaneous measurements of pO2 in newborns with RDS (author's transl)].
    Haschke F; Häckel F; Hohenauer L
    Klin Padiatr; 1976 Jan; 188(1):73-81. PubMed ID: 943670
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Non-invasive measurement of blood oxygen levels.
    Beyerl D
    Am J Med Technol; 1982 May; 48(5):355-9. PubMed ID: 7102718
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Transcutaneous measurement of PaO2 by the "TCM 1" electrode (author's transl)].
    Carthaus P; Podlesch I
    Prakt Anaesth; 1979 Aug; 14(4):345-7. PubMed ID: 493230
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Transcutaneous PO2 as a trend indicator of arterial PO2 in normal anesthesized adults.
    Rafferty TD; Marrero O; Nardi D; Schachter EN; Mentelos R; Ngeow YF
    Anesth Analg; 1982 Mar; 61(3):252-5. PubMed ID: 7199839
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.