These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

74 related articles for article (PubMed ID: 6747101)

  • 1. The attenuation of ultrasound in biological fluids.
    Narayana PA; Ophir J; Maklad NF
    J Acoust Soc Am; 1984 Jul; 76(1):1-4. PubMed ID: 6747101
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The acoustic properties, centered on 20 MHZ, of an IEC agar-based tissue-mimicking material and its temperature, frequency and age dependence.
    Brewin MP; Pike LC; Rowland DE; Birch MJ
    Ultrasound Med Biol; 2008 Aug; 34(8):1292-306. PubMed ID: 18343021
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vitro measurement of the frequency-dependent attenuation in cancellous bone between 0.2 and 2 MHz.
    Chaffaï S; Padilla F; Berger G; Laugier P
    J Acoust Soc Am; 2000 Sep; 108(3 Pt 1):1281-9. PubMed ID: 11008828
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Broadband measurements of the frequency dependence of attenuation coefficient and velocity in amniotic fluid, urine and human serum albumin solutions.
    Verma PK; Humphrey VF; Duck FA
    Ultrasound Med Biol; 2005 Oct; 31(10):1375-81. PubMed ID: 16223641
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Studies of acoustic streaming in biological fluids with an ultrasound Doppler technique.
    Zauhar G; Starritt HC; Duck FA
    Br J Radiol; 1998 Mar; 71(843):297-302. PubMed ID: 9616239
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Ultrasound attenuation measurements of the liver in vivo using a commercial sector scanner.
    Garra BS; Shawker TH; Nassi M; Russell MA
    Ultrason Imaging; 1984 Oct; 6(4):396-407. PubMed ID: 6399170
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Characterization of the ultrasonic attenuation coefficient and its frequency dependence in a polymer gel dosimeter.
    Crescenti RA; Bamber JC; Partridge M; Bush NL; Webb S
    Phys Med Biol; 2007 Nov; 52(22):6747-59. PubMed ID: 17975295
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Measurement of broadband temperature-dependent ultrasonic attenuation and dispersion using photoacoustics.
    Treeby BE; Cox BT; Zhang EZ; Patch SK; Beard PC
    IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Aug; 56(8):1666-76. PubMed ID: 19686982
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effects of nonlinear ultrasound propagation on high intensity brain therapy.
    Pinton G; Aubry JF; Fink M; Tanter M
    Med Phys; 2011 Mar; 38(3):1207-16. PubMed ID: 21520833
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ultrasonic backscatter and attenuation (11-27 MHz) variation with collagen fiber distribution in ex vivo human dermis.
    Bridal SL; Fournier C; Coron A; Leguerney I; Laugier P
    Ultrason Imaging; 2006 Jan; 28(1):23-40. PubMed ID: 16924880
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Peritransplant fluid collections. Ultrasound evaluation and clinical significance.
    Silver TM; Campbell D; Wicks JD; Lorber MI; Surace P; Turcotte J
    Radiology; 1981 Jan; 138(1):145-51. PubMed ID: 7005938
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The physics of diagnostic ultrasound.
    Buddemeyer EU
    Radiol Clin North Am; 1975 Dec; 13(3):391-402. PubMed ID: 1202571
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Acoustic velocity and attenuation of eye tissues at 20 MHz.
    de Korte CL; van der Steen AF; Thijssen JM
    Ultrasound Med Biol; 1994; 20(5):471-80. PubMed ID: 7941104
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Development and characterization of a blood mimicking fluid for high intensity focused ultrasound.
    Liu Y; Maruvada S; King RL; Herman BA; Wear KA
    J Acoust Soc Am; 2008 Sep; 124(3):1803-10. PubMed ID: 19045670
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ultrasonic characterization of human trabecular bone microstructure.
    Hakulinen MA; Day JS; Töyräs J; Weinans H; Jurvelin JS
    Phys Med Biol; 2006 Mar; 51(6):1633-48. PubMed ID: 16510968
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ultrasonic attenuation and backscatter from flowing whole blood are dependent on shear rate and hematocrit between 10 and 50 MHz.
    Huang CC; Chang YC
    IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Feb; 58(2):357-68. PubMed ID: 21342821
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Broadband attenuation and nonlinear propagation in biological fluids: an experimental facility and measurements.
    Verma PK; Humphrey VF; Duck FA
    Ultrasound Med Biol; 2005 Dec; 31(12):1723-33. PubMed ID: 16344135
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Acoustic Properties of Breast Fat.
    Nasief HG; Rosado-Mendez IM; Zagzebski JA; Hall TJ
    J Ultrasound Med; 2015 Nov; 34(11):2007-16. PubMed ID: 26446820
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Spatial variation of acoustic parameters in human skin: an in vitro study between 22 and 45 MHz.
    Lebertre M; Ossant F; Vaillant L; Diridollou S; Patat F
    Ultrasound Med Biol; 2002 May; 28(5):599-615. PubMed ID: 12079697
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Frequency-dependent ultrasonic differentiation of normal and diffusely diseased liver.
    Lin T; Ophir J; Potter G
    J Acoust Soc Am; 1987 Oct; 82(4):1131-8. PubMed ID: 3316337
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.