These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

153 related articles for article (PubMed ID: 6761356)

  • 1. Quantitative microbiological monitoring of hemodialysis fluids: evaluation of methods and demonstration of lack of test relevance in single-pass hemodialysis machines with automatic dialysate proportioning with reverse osmosis-treated tap water.
    Doern GV; Brogden BE; DiFederico JD; Earls JE; Quinn ML
    J Clin Microbiol; 1982 Dec; 16(6):1025-9. PubMed ID: 6761356
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of microbiologic assay methods for hemodialysis fluids.
    Arduino MJ; Bland LA; Aguero SM; Carson L; Ridgeway M; Favero MS
    J Clin Microbiol; 1991 Mar; 29(3):592-4. PubMed ID: 2037676
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Improved bacteriological surveillance of haemodialysis fluids: a comparison between Tryptic soy agar and Reasoner's 2A media.
    van der Linde K; Lim BT; Rondeel JM; Antonissen LP; de Jong GM
    Nephrol Dial Transplant; 1999 Oct; 14(10):2433-7. PubMed ID: 10528669
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Guidelines on water and solutions for dialysis. Italian Society of Nephrology].
    Alloatti S; Bolasco P; Canavese C; Cappelli G; Pedrini L; Pizzarelli F; Pontoriero G; Santoro A; Anastasio P; Teatini U; Fuiano G;
    G Ital Nefrol; 2005; 22(3):246-73. PubMed ID: 16001369
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The bacteriological quality of hemodialysis solution as related to several environmental factors.
    Lauer J; Streifel A; Kjellstrand C; DeRoos R
    Nephron; 1975; 15(2):87-97. PubMed ID: 807862
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Factors that influence microbial contamination of fluids associated with hemodialysis machines.
    Favero MS; Carson LA; Bond WW; Petersen NJ
    Appl Microbiol; 1974 Nov; 28(5):822-30. PubMed ID: 4216291
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Gram-negative water bacteria in hemodialysis systems.
    Favero MS; Petersen NJ; Carson LA; Bond WW; Hindman SH
    Health Lab Sci; 1975 Oct; 12(4):321-34. PubMed ID: 1236620
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Quality of hemodialysis water: a 7-year multicenter study.
    Laurence RA; Lapierre ST
    Am J Kidney Dis; 1995 May; 25(5):738-50. PubMed ID: 7747728
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [The role of pharmacist in a telemedicine collaboration in hemodialysis: Water bacteriological quality monitoring].
    Letournel C; Montecot V
    Ann Pharm Fr; 2018 May; 76(3):235-241. PubMed ID: 29361269
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Contamination of dialysis water and dialysate. A survey of 30 centers.
    Bambauer R; Schauer M; Jung WK; Daum V; Vienken J
    ASAIO J; 1994; 40(4):1012-6. PubMed ID: 7858320
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Production and control of water quality for hemodialysis].
    Tarchini R; Botti P; Marseglia CD; Brescia P; Serra A; Mazzola G; Rovinetti G
    G Ital Nefrol; 2012; 29 Suppl 58():S83-94. PubMed ID: 23229609
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Bacteriology of hemodialysis fluids: are current methodologies meaningful?
    Harding GB; Pass T; Wright R
    Artif Organs; 1992 Oct; 16(5):448-56. PubMed ID: 10078291
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Bacterial contamination of hemodialysis center water and dialysate: are current assays adequate?
    Harding GB; Pass T; Million C; Wright R; DeJarnette J; Klein E
    Artif Organs; 1989 Apr; 13(2):155-9. PubMed ID: 2650659
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [A study on the endotoxin and bacterial contamination in reverse osmosis water and dialysis fluids].
    Liu H; Li G; Zhang X; Duan X; Yao Y
    Zhonghua Nei Ke Za Zhi; 1999 Dec; 38(12):806-9. PubMed ID: 11798721
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dialysis fluid contamination of pathways and life of microbes.
    Nystrand R
    EDTNA ERCA J; 2001; 27(3):135-9. PubMed ID: 11868995
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Microbiology of water and fluids for hemodialysis.
    Nystrand R
    J Chin Med Assoc; 2008 May; 71(5):223-9. PubMed ID: 18490224
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Microbial contamination of dialysate and its prevention in haemodialysis units.
    Oie S; Kamiya A; Yoneda I; Uchiyama K; Tsuchida M; Takai K; Naito K
    J Hosp Infect; 2003 Jun; 54(2):115-9. PubMed ID: 12818584
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Microbiological quality of water and dialysate in a haemodialysis unit in Ponta Grossa-PR, Brazil.
    Borges CR; Lascowski KM; Filho NR; Pelayo JS
    J Appl Microbiol; 2007 Nov; 103(5):1791-7. PubMed ID: 17953589
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Water treatment for hemodialysis--updated to include the latest AAMI standards for dialysate (RD52: 2004) continuing.
    Amato RL
    Nephrol Nurs J; 2005; 32(2):151-67; quiz 168-70. PubMed ID: 15889801
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Bacteriological monitoring of dialysis fluid in 2 hemodialysis units in Alexandria, Egypt.
    El-Koraie AF; Hazzah WA; Abbass AA; El-Shazly SA
    Saudi Med J; 2007 Aug; 28(8):1234-8. PubMed ID: 17676209
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]