These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 6768097)

  • 1. Test of a pion range monitor using the radiative capture of pions on protons pi-p leads to n gamma.
    Büche G; Kluge W; Matthäy H; Moline A; Münchmeyer D; Schmidt D
    Radiat Environ Biophys; 1980 Feb; 17(2):169-85. PubMed ID: 6768097
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Neutron doses in negative pion radiotherapy.
    Vilaithong T; Madey R; Witten TR; Anderson BD; Baldwin AR; Waterman FM
    Phys Med Biol; 1983 Jul; 28(7):799-816. PubMed ID: 6412259
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Proportional counter dosimetry and microdosimetry for radiotherapy with multiple pion beams.
    Schuhmacher H; Menzel HG; Blattmann H; Muth H
    Radiat Res; 1985 Jan; 101(1):177-96. PubMed ID: 3918330
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The PIOTRON: initial performance, preparation and experience with pion therapy.
    von Essen CF; Blattmann H; Crawford JF; Fessenden P; Pedroni E; Perret C; Salzmann M; Shortt K; Walder E
    Int J Radiat Oncol Biol Phys; 1982 Sep; 8(9):1499-509. PubMed ID: 6815138
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effects of a bolus and inhomogeneities on pion stopping distributions.
    Wright HA; Turner JE; Hamm RN
    Med Phys; 1984; 11(6):751-4. PubMed ID: 6439988
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Energy deposition spectra of pi- calculated from pion nucleus interaction data.
    Büche G
    Radiat Environ Biophys; 1982; 20(4):255-62. PubMed ID: 6292991
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Pion in vivo dosimetry using aluminum activation.
    Hogstrom KR; Amols HI
    Med Phys; 1980; 7(1):55-60. PubMed ID: 6767905
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Influence of beam characteristics and detector size in negative-pion dose studies.
    Hamm RN; Wright HA; Turner JE
    Phys Med Biol; 1979 May; 24(3):613-20. PubMed ID: 461520
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Muon dose distribution from a decaying pencil beam of pions.
    Brosing JW; Henkelman RM
    Phys Med Biol; 1981 Jul; 26(4):633-40. PubMed ID: 6789343
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Photonuclear dose calculations for high-energy photon beams from Siemens and Varian linacs.
    Chibani O; Ma CM
    Med Phys; 2003 Aug; 30(8):1990-2000. PubMed ID: 12945965
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A lyoluminescent tissue-equivalent dosemeter for pion therapy beams.
    Atari NA; Malik SR; Brenner DJ; Hilko R; Bradbury JN
    Phys Med Biol; 1983 May; 28(5):493-502. PubMed ID: 6408655
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of different stopping volumes of clinical pion beams at TRIUMF on the mouse small intestine.
    Saito T; Chaplin DJ; Lam GK; Skarsgard LD
    Radiat Res; 1989 Jan; 117(1):8-20. PubMed ID: 2492379
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dose outside the treatment volume for irradiation with negative pions.
    Amols HI; Bradbury JN; Dicello JF; Helland JA; Kligerman MM; Lane TF; Paciotti MA; Roeder DL; Schillaci ME
    Phys Med Biol; 1978 May; 23(3):385-96. PubMed ID: 674356
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Are neutrons responsible for the dose discrepancies between Monte Carlo calculations and measurements in the build-up region for a high-energy photon beam?
    Ding GX; Duzenli C; Kalach NI
    Phys Med Biol; 2002 Sep; 47(17):3251-61. PubMed ID: 12361221
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dose and LET distributions due to neutrons and photons emitted from stopped negative pions.
    Brenner DJ; Smith FA
    Phys Med Biol; 1977 May; 22(3):451-65. PubMed ID: 866409
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Measurement of stopping power ratios for 60 MeV positive or negative pions.
    Nordin JA; Henkelman RM
    Phys Med Biol; 1979 Jul; 24(4):781-92. PubMed ID: 112597
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Characteristics of a negative pion beam in a therapeutic application.
    Richman C
    Radiology; 1975 Jul; 116(1):187-9. PubMed ID: 806098
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The three dose components of negative pion beam and their role in pion radiotherapy.
    Richman C; Rodriguez JF; Malcom JE; Stein ML
    Radiology; 1978 Sep; 128(3):757-66. PubMed ID: 97731
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pion radiotherapy: studies with nuclear emulsions.
    Allred JC; Bradbury JN; Rosen L; Hungerford EV; Kidder HR; Osborne WZ; Phillips GC
    Phys Med Biol; 1978 Jul; 23(4):603-9. PubMed ID: 100794
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The comparative survival of clonogenic cells of a murine epithelioma irradiated in vivo with 250 kVp X rays, 60Co gamma rays, or negative pions produced by the cyclotron at TRIUMF.
    Sakamoto K; Okada S; Lam GK; Henkelman RM; Skarsgard LD
    Radiology; 1979 Nov; 133(2):501-5. PubMed ID: 115061
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.