148 related articles for article (PubMed ID: 6773435)
1. Correction for gas compression in mechanical ventilators.
Forbat AF; Her C
Anesth Analg; 1980 Jul; 59(7):488-93. PubMed ID: 6773435
[TBL] [Abstract][Full Text] [Related]
2. The effects of passive humidifier dead space on respiratory variables in paralyzed and spontaneously breathing patients.
Campbell RS; Davis K; Johannigman JA; Branson RD
Respir Care; 2000 Mar; 45(3):306-12. PubMed ID: 10771799
[TBL] [Abstract][Full Text] [Related]
3. A simple VD/VT gas-collection valve for use with Siemens ventilators.
Ritz R; Crogan S
Respir Care; 1986 Nov; 31(11):1096-8. PubMed ID: 10315716
[TBL] [Abstract][Full Text] [Related]
4. Correction for mechanical dead space in the calculation of physiological dead space.
Singleton GJ; Olsen CR; Smith RL
J Clin Invest; 1972 Oct; 51(10):2768-72. PubMed ID: 5056668
[TBL] [Abstract][Full Text] [Related]
5. Calculation of physiologic dead space: comparison of ventilator volumetric capnography to measurements by metabolic analyzer and volumetric CO2 monitor.
Siobal MS; Ong H; Valdes J; Tang J
Respir Care; 2013 Jul; 58(7):1143-51. PubMed ID: 23232740
[TBL] [Abstract][Full Text] [Related]
6. [Comparison of volume preset and pressure preset ventilators during daytime nasal ventilation in chronic respiratory failure].
Perrin C; Wolter P; Berthier F; Tamisier R; Jullien V; Lemoigne F; Blaive B
Rev Mal Respir; 2001 Feb; 18(1):41-8. PubMed ID: 14639176
[TBL] [Abstract][Full Text] [Related]
7. Accuracy of physiologic deadspace measurement in intubated pediatric patients using a metabolic monitor: comparison with the Douglas bag method.
Lum L; Saville A; Venkataraman ST
Crit Care Med; 1998 Apr; 26(4):760-4. PubMed ID: 9559616
[TBL] [Abstract][Full Text] [Related]
8. Respiratory deadspace measurements in neonates during extracorporeal membrane oxygenation.
Arnold JH; Thompson JE; Benjamin PK
Crit Care Med; 1993 Dec; 21(12):1895-900. PubMed ID: 8252895
[TBL] [Abstract][Full Text] [Related]
9. Dead space ventilation in volume controlled versus pressure controlled mode of mechanical ventilation.
Wathanasormsiri A; Preutthipan A; Chantarojanasiri T; Suwanjutha S
J Med Assoc Thai; 2002 Nov; 85 Suppl 4():S1207-12. PubMed ID: 12549796
[TBL] [Abstract][Full Text] [Related]
10. Accuracy of physiologic dead space measurements in patients with acute respiratory distress syndrome using volumetric capnography: comparison with the metabolic monitor method.
Kallet RH; Daniel BM; Garcia O; Matthay MA
Respir Care; 2005 Apr; 50(4):462-7. PubMed ID: 15807908
[TBL] [Abstract][Full Text] [Related]
11. Unevenness of ventilation assessed by the expired CO(2) gas volume versus V(T) curve in asthmatic patients.
Koulouris NG; Latsi P; Stavrou E; Chroneou A; Gaga M; Jordanoglou J
Respir Physiol Neurobiol; 2004 Jun; 140(3):293-300. PubMed ID: 15186790
[TBL] [Abstract][Full Text] [Related]
12. Effects of continuous, expiratory, reverse, and bi-directional tracheal gas insufflation in conjunction with a flow relief valve on delivered tidal volume, total positive end-expiratory pressure, and carbon dioxide elimination: a bench study.
Delgado E; Hete B; Hoffman LA; Tasota FJ; Pinsky MR
Respir Care; 2001 Jun; 46(6):577-85. PubMed ID: 11353546
[TBL] [Abstract][Full Text] [Related]
13. The effect of increased apparatus dead space and tidal volumes on carbon dioxide elimination and oxygen saturations in a low-flow anesthesia system.
Enekvist BJ; Luttropp HH; Johansson A
J Clin Anesth; 2008 May; 20(3):170-4. PubMed ID: 18502358
[TBL] [Abstract][Full Text] [Related]
14. Effect of inspiratory time on tidal volume delivery in anesthesia and intensive care unit ventilators operating in pressure control mode.
Tung A; Drum ML; Morgan S
J Clin Anesth; 2005 Feb; 17(1):8-15. PubMed ID: 15721723
[TBL] [Abstract][Full Text] [Related]
15. Relationship between physiologic deadspace/tidal volume ratio and gas exchange in infants with acute bronchiolitis on invasive mechanical ventilation.
Almeida-Junior AA; da Silva MT; Almeida CC; Ribeiro JD
Pediatr Crit Care Med; 2007 Jul; 8(4):372-7. PubMed ID: 17545938
[TBL] [Abstract][Full Text] [Related]
16. Correction of error in respiratory resistance measurements made with the flow-interruption technique during mechanical ventilation: evaluation of the puritan bennett 7200 and 840 ventilators.
Lit LM; Doelken P; Mayo PH
Respir Care; 2004 Sep; 49(9):1022-8. PubMed ID: 15329173
[TBL] [Abstract][Full Text] [Related]
17. Assessment of errors when expiratory condensate PCO2 is used as a proxy for mixed expired PCO2 during mechanical ventilation.
Imanaka H; Hess D; al-Himyary A; Bigatello LM; Ritz R; Kacmarek RM; Hurford WE
J Clin Monit; 1997 Jul; 13(4):215-22. PubMed ID: 9269614
[TBL] [Abstract][Full Text] [Related]
18. Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation?
Bachiller PR; McDonough JM; Feldman JM
Anesth Analg; 2008 May; 106(5):1392-400, table of contents. PubMed ID: 18420850
[TBL] [Abstract][Full Text] [Related]
19. Variations in tidal volume with portable transport ventilators.
McGough EK; Banner MJ; Melker RJ
Respir Care; 1992 Mar; 37(3):233-9. PubMed ID: 10145629
[TBL] [Abstract][Full Text] [Related]
20. Compression volume in adult ventilator circuits: a comparison of five disposable circuits and a nondisposable circuit.
Hess D; McCurdy S; Simmons M
Respir Care; 1991 Oct; 36(10):1113-8. PubMed ID: 10145567
[TBL] [Abstract][Full Text] [Related]