These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 6779845)

  • 1. Measurement of metabolic gas exchange during anaesthesia. A method using mass spectrometry.
    Heneghan CP; Gillbe CE; Branthwaite MA
    Br J Anaesth; 1981 Jan; 53(1):73-6. PubMed ID: 6779845
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A multipatient mass spectrometer based system for the measurement of metabolic gas exchange in artificially ventilated intensive care patients.
    Roberts MJ; Boustred ML; Hinds CJ
    Intensive Care Med; 1983; 9(6):339-43. PubMed ID: 6418783
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Validation of a system for measurement of metabolic gas exchange during anaesthesia with controlled ventilation in an oxygen consuming lung model.
    Svensson KL; Sonander HG; Stenqvist O
    Br J Anaesth; 1990 Mar; 64(3):311-9. PubMed ID: 2328180
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Mass spectrometer measurement of oxygen uptake and carbon dioxide exchange during cardiopulmonary bypass.
    Abbott TR; Goodwin B; Clark G; Rees GJ
    Br J Anaesth; 1980 Jan; 52(1):29-40. PubMed ID: 6769449
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Non-invasive measurement of cardiac output during anaesthesia. An evaluation of the soluble gas uptake method.
    Heneghan CP; Branthwaite MA
    Br J Anaesth; 1981 Apr; 53(4):351-5. PubMed ID: 7225268
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Noninvasive measurement of pulmonary gas exchange during general anesthesia.
    Noe FE; Whitty AJ; Davies KR; Wickham BL
    Anesth Analg; 1980 Apr; 59(4):263-9. PubMed ID: 6768319
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Clinical validation of a new metabolic monitor suitable for use in critically ill patients.
    Nelson LD; Anderson HB; Garcia H
    Crit Care Med; 1987 Oct; 15(10):951-7. PubMed ID: 3115680
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Metabolic gas exchange during nitrous oxide anaesthesia with controlled ventilation.
    Svensson KL; Henriksson BA; Sonander H; Stenqvist O
    Br J Anaesth; 1990 Mar; 64(3):320-6. PubMed ID: 2109626
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Continuous measurement of pulmonary gas exchange during general anaesthesia in man.
    Viale JP; Annat G; Bertrand O; Thouverez B; Hoen JP; Motin J
    Acta Anaesthesiol Scand; 1988 Nov; 32(8):691-7. PubMed ID: 3213395
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A small bypass mixing chamber for monitoring metabolic rate and anesthetic uptake: the bymixer.
    Sanjo Y; Ikeda K
    J Clin Monit; 1987 Oct; 3(4):235-43. PubMed ID: 3119784
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Measurement of lung volume by multiple indicator dilution. Differences in apparent volumes of distribution of oxygen, nitrogen and argon.
    Black AM; Hahn CE; Maynard P; Scott IL
    Br J Anaesth; 1984 Mar; 56(3):289-98. PubMed ID: 6422970
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Respiratory mass spectrometry during general anaesthesia.
    Gillbe CE; Heneghan CP; Branthwaite MA
    Br J Anaesth; 1981 Jan; 53(1):103-9. PubMed ID: 6779842
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In vivo validation of the M-COVX metabolic monitor in patients under anaesthesia.
    Stuart-Andrews CR; Peyton P; Robinson GJ; Terry D; O'Connor B; Van der Herten C; Lithgow B
    Anaesth Intensive Care; 2007 Jun; 35(3):398-405. PubMed ID: 17591136
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Direct expiratory gas analysis after hypothermic cardiopulmonary bypass.
    Moriyama S; Utoh J; Okamoto K; Tanaka M; Kunitomo R; Hara M; Kitamura N
    Ann Thorac Cardiovasc Surg; 1999 Jun; 5(3):150-5. PubMed ID: 10413760
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Carbon dioxide output in laparoscopic cholecystectomy.
    Kazama T; Ikeda K; Kato T; Kikura M
    Br J Anaesth; 1996 Apr; 76(4):530-5. PubMed ID: 8652326
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Continuous measurement of oxygen consumption during cardiopulmonary bypass: description of the method and in vivo observations.
    Li J; Stokoe J; Konstantinov IE; Edgell D; Cheung MM; Kharbanda RK; Redington AN
    Ann Thorac Surg; 2004 May; 77(5):1671-7. PubMed ID: 15111164
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The accuracy and precision of an open-circuit system to measure oxygen consumption and carbon dioxide production in neonates.
    Marks KH; Coen P; Kerrigan JR; Francalancia NA; Nardis EE; Snider MT
    Pediatr Res; 1987 Jan; 21(1):58-65. PubMed ID: 3099255
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of meperidine on oxygen consumption, carbon dioxide production, and respiratory gas exchange in postanesthesia shivering.
    Macintyre PE; Pavlin EG; Dwersteg JF
    Anesth Analg; 1987 Aug; 66(8):751-5. PubMed ID: 3111305
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of metabolic monitors in critically ill, ventilated patients.
    Singer P; Pogrebetsky I; Attal-Singer J; Cohen J
    Nutrition; 2006; 22(11-12):1077-86. PubMed ID: 16973331
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Measurement of gas exchange in anesthesia and during resuscitation: principles and applications].
    Viale JP; Annat G; Delafosse B; Bouffard Y; Tissot S; Motin J
    Agressologie; 1990 Jan; 31(1):62-3. PubMed ID: 2114063
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.