212 related articles for article (PubMed ID: 6790150)
1. Disinfecting endoscopes: how not to transmit Mycobacterium tuberculosis by bronchoscopy.
Leers WD
Can Med Assoc J; 1980 Aug; 123(4):275-80, 283. PubMed ID: 6790150
[TBL] [Abstract][Full Text] [Related]
2. Disinfection of the flexible fibreoptic bronchoscope against Mycobacterium tuberculosis and M gordonae.
Davis D; Bonekat HW; Andrews D; Shigeoka JW
Thorax; 1984 Oct; 39(10):785-8. PubMed ID: 6437002
[TBL] [Abstract][Full Text] [Related]
3. Transmission of tuberculosis by flexible fiberbronchoscopes.
Nelson KE; Larson PA; Schraufnagel DE; Jackson J
Am Rev Respir Dis; 1983 Jan; 127(1):97-100. PubMed ID: 6401418
[TBL] [Abstract][Full Text] [Related]
4. A study of glutaraldehyde disinfection of fibreoptic bronchoscopes experimentally contaminated with Mycobacterium tuberculosis.
Hanson PJ; Chadwick MV; Gaya H; Collins JV
J Hosp Infect; 1992 Oct; 22(2):137-42. PubMed ID: 1358955
[TBL] [Abstract][Full Text] [Related]
5. A pseudoepidemic of Mycobacterium chelonae: contamination of a bronchoscope and autocleaner.
Campagnaro RL; Teichtahl H; Dwyer B
Aust N Z J Med; 1994 Dec; 24(6):693-5. PubMed ID: 7717921
[TBL] [Abstract][Full Text] [Related]
6. Disinfection of upper gastrointestinal fibreoptic endoscopy equipment: an evaluation of a cetrimide chlorhexidine solution and glutaraldehyde.
Carr-Locke DL; Clayton P
Gut; 1978 Oct; 19(10):916-22. PubMed ID: 101424
[TBL] [Abstract][Full Text] [Related]
7. [The transmission of mycobacteria through the fiberoptic bronchoscope].
Bezel R; Salfinger M; Brändli O
Schweiz Med Wochenschr; 1985 Sep; 115(39):1360-5. PubMed ID: 3934749
[TBL] [Abstract][Full Text] [Related]
8. Mycobacterium gordonae in fiberoptic bronchoscopes.
Jackson J; Leggett JE; Wilson DA; Gilbert DN
Am J Infect Control; 1996 Feb; 24(1):19-23. PubMed ID: 8651516
[TBL] [Abstract][Full Text] [Related]
9. Liquid disinfecting and sterilization reprocessors used for flexible endoscopes.
Health Devices; 1994 Jun; 23(6):212-53. PubMed ID: 7852072
[TBL] [Abstract][Full Text] [Related]
10. Cleaning, disinfecting procedures help control spread of infection.
Crow S
Hospitals; 1978 Dec; 52(23):111-3. PubMed ID: 700657
[TBL] [Abstract][Full Text] [Related]
11. Transmission of Mycobacterium tuberculosis by a fiberoptic bronchoscope. Identification by DNA fingerprinting.
Michele TM; Cronin WA; Graham NM; Dwyer DM; Pope DS; Harrington S; Chaisson RE; Bishai WR
JAMA; 1997 Oct; 278(13):1093-5. PubMed ID: 9315769
[TBL] [Abstract][Full Text] [Related]
12. Cleaning and disinfection of fiberoptic endoscopes: evaluation of glutaraldehyde exposure time and forced-air drying.
Gerding DN; Peterson LR; Vennes JA
Gastroenterology; 1982 Sep; 83(3):613-8. PubMed ID: 6807738
[TBL] [Abstract][Full Text] [Related]
13. Pseudo-outbreak of Mycobacterium chelonae and Methylobacterium mesophilicum caused by contamination of an automated endoscopy washer.
Kressel AB; Kidd F
Infect Control Hosp Epidemiol; 2001 Jul; 22(7):414-8. PubMed ID: 11583208
[TBL] [Abstract][Full Text] [Related]
14. Efficiency of the glutaraldehyde test strip for monitoring the concentration of glutaraldehyde in reused solutions for disinfecting endoscopes.
Keerasuntonpong A; Sitaposa P; Chaiprasert A; Thamlikitkul V
J Med Assoc Thai; 2002 Nov; 85(11):1164-8. PubMed ID: 12546312
[TBL] [Abstract][Full Text] [Related]
15. A rapid method of disinfecting the bronchofiberscope.
Suratt PM; Gwaltney JM; Sande MA
Am Rev Respir Dis; 1976 Dec; 114(6):1198-9. PubMed ID: 1008353
[TBL] [Abstract][Full Text] [Related]
16. A pseudoepidemic of Mycobacterium chelonae infection caused by contamination of a fibreoptic bronchoscope suction channel.
Wang HC; Liaw YS; Yang PC; Kuo SH; Luh KT
Eur Respir J; 1995 Aug; 8(8):1259-62. PubMed ID: 7489787
[TBL] [Abstract][Full Text] [Related]
17. [Contamination of a bronchial fiberscope by mycobacteria linked to an automated bronchoscope disinfection machine].
Nomura K; Ogawa M; Chang B; Miyamoto H; Tanabe T; Taniguchi H; Matsumoto T
J UOEH; 2000 Jun; 22(2):159-65. PubMed ID: 10862410
[TBL] [Abstract][Full Text] [Related]
18. [Automatic disinfection of fiberendoscopes (author's transl)].
Baas EU
Zentralbl Bakteriol Orig B; 1977 Dec; 165(5-6):458-63. PubMed ID: 416628
[TBL] [Abstract][Full Text] [Related]
19. Cleaning and disinfection of equipment for gastrointestinal endoscopy. Report of a Working Party of the British Society of Gastroenterology Endoscopy Committee.
BSG E
Gut; 1998 Apr; 42(4):585-93. PubMed ID: 9616326
[TBL] [Abstract][Full Text] [Related]
20. Cleaning, disinfection, and sterilization of gastrointestinal endoscopes: approaches in the office.
Tremain SC; Orientale E; Rodney WM
J Fam Pract; 1991 Mar; 32(3):300-5. PubMed ID: 2002322
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]