125 related articles for article (PubMed ID: 6797219)
1. Control of carbon dioxide in modified Mapleson A and D (Hafnia) anaesthetic systems. An experimental model.
Andersen PK
Acta Anaesthesiol Scand; 1981 Aug; 25(4):344-8. PubMed ID: 6797219
[TBL] [Abstract][Full Text] [Related]
2. Flow requirements and rebreathing during mechanically controlled ventilation in a T-piece (Mapleson E) system.
Hatch DJ; Yates AP; Lindahl SG
Br J Anaesth; 1987 Dec; 59(12):1533-40. PubMed ID: 3122808
[TBL] [Abstract][Full Text] [Related]
3. A comparison of anaesthetic breathing systems during spontaneous ventilation. An in-vitro study using a lung model.
Chan AS; Bruce WE; Soni N
Anaesthesia; 1989 Mar; 44(3):194-9. PubMed ID: 2495742
[TBL] [Abstract][Full Text] [Related]
4. Distribution of expiratory gas and rebreathing in a T-piece modification combined with a PEEP valve.
Hartmann-Andersen F; Andersen PK; Olsen JE; Jakubaszko J
Acta Anaesthesiol Scand; 1984 Dec; 28(6):671-6. PubMed ID: 6441434
[TBL] [Abstract][Full Text] [Related]
5. Ventilatory responses to rebreathing and carbon dioxide inhalation during anaesthesia in children.
Lindahl SG; Charlton AJ; Hatch DJ
Br J Anaesth; 1985 Dec; 57(12):1188-96. PubMed ID: 3936525
[TBL] [Abstract][Full Text] [Related]
6. Carbon dioxide tensions in manually ventilated, prone patients.
Andersen PK; Stokke DB; Hole P; Nielsen H; Rosendal T
Anaesthesist; 1981 Dec; 30(12):610-3. PubMed ID: 6800280
[TBL] [Abstract][Full Text] [Related]
7. A new hybrid anaesthetic circuit for a low-flow rebreathing technique.
Mentell O; Revenäs B; Jonsson L
Acta Anaesthesiol Scand; 1994 Nov; 38(8):840-4. PubMed ID: 7887108
[TBL] [Abstract][Full Text] [Related]
8. Effect of inspiration-expiration ratio on rebreathing with the Mapleson D system (Bain's modification; coaxial system).
Gabrielsen J; van den Berg JT; Dirksen H; Ruben H
Acta Anaesthesiol Scand; 1980 Aug; 24(4):336-8. PubMed ID: 6781209
[TBL] [Abstract][Full Text] [Related]
9. How rebreathing anaesthetic systems control PaCO2: studies with a mechanical and a mathematical model.
Keenan RL; Boyan CP
Can Anaesth Soc J; 1978 Mar; 25(2):117-21. PubMed ID: 638822
[TBL] [Abstract][Full Text] [Related]
10. Spontaneous breathing with a T-piece circuit: minimum fresh gas/minute volume ratio which prevents rebreathing.
Dean SE; Keenan RL
Anesthesiology; 1982 Jun; 56(6):449-52. PubMed ID: 6805364
[TBL] [Abstract][Full Text] [Related]
11. Sources of error and their correction in the measurement of carbon dioxide elimination using the Siemens-Elema CO2 Analyzer.
Fletcher R; Werner O; Nordström L; Jonson B
Br J Anaesth; 1983 Feb; 55(2):177-85. PubMed ID: 6219687
[TBL] [Abstract][Full Text] [Related]
12. Respiratory waveform and rebreathing in T-piece circuits: a comparison of enflurane and halothane waveforms.
Byrick RJ; Janssen EG
Anesthesiology; 1980 Nov; 53(5):371-8. PubMed ID: 6775562
[TBL] [Abstract][Full Text] [Related]
13. The parallel Lack anaesthetic breathing system.
Ooi R; Lack JA; Soni N; Whittle J; Pattison J
Anaesthesia; 1993 May; 48(5):409-14. PubMed ID: 8317651
[TBL] [Abstract][Full Text] [Related]
14. Carbon dioxide distribution in Mapleson A and D systems: an experimental study.
Andersen PK; Olsen JE; Jensen A; Stokke DB
Acta Anaesthesiol Scand; 1989 Aug; 33(6):439-43. PubMed ID: 2508406
[TBL] [Abstract][Full Text] [Related]
15. Single lever Humphrey A.D.E. low flow universal anaesthetic breathing system. Part I: Comparison with dual lever A.D.E., Magill and Bain systems in anaesthetized spontaneously breathing adults.
Humphrey D; Brock-Utne JG; Downing JW
Can Anaesth Soc J; 1986 Nov; 33(6):698-709. PubMed ID: 3096542
[TBL] [Abstract][Full Text] [Related]
16. Comparison of anti-pollution modifications of Mapleson A and D anaesthetic systems.
Andersen PK; Hole P
Br J Anaesth; 1979 Aug; 51(8):797-9. PubMed ID: 159068
[TBL] [Abstract][Full Text] [Related]
17. Rebreathing characteristics of the Bain circuit. An experimental and theoretical study.
Stenqvist O; Sonander H
Br J Anaesth; 1984 Mar; 56(3):303-10. PubMed ID: 6422971
[TBL] [Abstract][Full Text] [Related]
18. A mass balance model for the Mapleson D anaesthesia breathing system.
Lovich MA; Simon BA; Venegas JG; Sims NM; Cooper JB
Can J Anaesth; 1993 Jun; 40(6):554-67. PubMed ID: 8403123
[TBL] [Abstract][Full Text] [Related]
19. An evaluation of fresh gas flow rates for spontaneously breathing cats and small dogs on the Humphrey ADE semi-closed breathing system.
Gale E; Ticehurst KE; Zaki S
Vet Anaesth Analg; 2015 May; 42(3):292-8. PubMed ID: 25039422
[TBL] [Abstract][Full Text] [Related]
20. Fresh gas flow in coaxial Mapleson A and D circuits during spontaneous breathing.
Jonsson LO; Zetterström H
Acta Anaesthesiol Scand; 1986 Oct; 30(7):588-93. PubMed ID: 3101384
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]