BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

297 related articles for article (PubMed ID: 6798391)

  • 1. Characteristics of an 18 MV photon beam from a Therac 20 Medical Linear Accelerator.
    Patterson MS; Shragge PC
    Med Phys; 1981; 8(3):312-8. PubMed ID: 6798391
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measurements of backscattered radiation from Therac-20 collimator and trimmer jaws into beam monitor chamber.
    Kubo H; Lo KK
    Med Phys; 1989; 16(2):292-4. PubMed ID: 2497316
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Monte Carlo study of in-field and out-of-field dose distributions from a linear accelerator operating with and without a flattening-filter.
    Almberg SS; Frengen J; Lindmo T
    Med Phys; 2012 Aug; 39(8):5194-203. PubMed ID: 22894444
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Photon beam quality variations of a flattening filter free linear accelerator.
    Georg D; Kragl G; Wetterstedt Sa; McCavana P; McClean B; Knöös T
    Med Phys; 2010 Jan; 37(1):49-53. PubMed ID: 20175465
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Scatter factor corrections for elongated fields.
    Higgins PD; Sohn WH; Sibata CH; McCarthy WA
    Med Phys; 1989; 16(5):800-2. PubMed ID: 2509871
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Characteristics of the high-energy photon beam of a 25-MeV accelerator.
    Luxton G; Astrahan MA
    Med Phys; 1988; 15(1):82-7. PubMed ID: 3127667
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Characterization of megavoltage electron beams delivered through a photon multi-leaf collimator (pMLC).
    du Plessis FC; Leal A; Stathakis S; Xiong W; Ma CM
    Phys Med Biol; 2006 Apr; 51(8):2113-29. PubMed ID: 16585849
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Buildup region and skin-dose measurements for the Therac 6 linear accelerator for radiation therapy.
    Tannous NB; Gagnon WF; Almond PR
    Med Phys; 1981; 8(3):378-81. PubMed ID: 6798394
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Output factor constituents of a high-energy photon beam.
    Luxton G; Astrahan MA
    Med Phys; 1988; 15(1):88-91. PubMed ID: 3127668
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dosimetry of 24-MV x rays from a linear accelerator.
    Krithivas G; Rao SN
    Med Phys; 1987; 14(2):274-81. PubMed ID: 3587155
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Depth dose characteristics of 24-MV x-ray beams at extended SSD.
    Jani SK; Pennington EC
    Med Phys; 1991; 18(2):292-4. PubMed ID: 1904530
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Elongation effects on the Therac 6 linear accelerator.
    Dawson DJ
    Med Phys; 1978; 5(5):439-42. PubMed ID: 101761
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Beam characteristics of a retrofitted double-focused multileaf collimator.
    Das IJ; Desobry GE; McNeeley SW; Cheng EC; Schultheiss TE
    Med Phys; 1998 Sep; 25(9):1676-84. PubMed ID: 9775373
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An investigation of accelerator head scatter and output factor in air.
    Ding GX
    Med Phys; 2004 Sep; 31(9):2527-33. PubMed ID: 15487734
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Scatter factors for a 25-MV x-ray beam.
    Bjärngard BE
    Med Phys; 1993; 20(2 Pt 1):357-61. PubMed ID: 8497222
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Characteristics of a spoiled 6-MV beam from a dual-energy linear accelerator.
    Lee PC; Thomason C; Glasgow GP
    Med Phys; 1993; 20(3):717-21. PubMed ID: 8350824
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dosimetric characterization of the 18-MV photon beam from the Siemens Mevatron 77 linear accelerator.
    Palta JR; Meyer JA; Hogstrom KR
    Med Phys; 1984; 11(5):717-24. PubMed ID: 6438461
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A comparison of phantom scatter from flattened and flattening filter free high-energy photon beams.
    Richmond N; Allen V; Daniel J; Dacey R; Walker C
    Med Dosim; 2015; 40(1):58-63. PubMed ID: 25454113
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measurements of in-air output ratios for a linear accelerator with and without the flattening filter.
    Zhu XR; Kang Y; Gillin MT
    Med Phys; 2006 Oct; 33(10):3723-33. PubMed ID: 17089838
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Buildup/surface dose and exit dose measurements for a 6-MV linear accelerator.
    Purdy JA
    Med Phys; 1986; 13(2):259-62. PubMed ID: 3084928
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]