297 related articles for article (PubMed ID: 6798391)
21. Commissioning and dosimetric characteristics of TrueBeam system: composite data of three TrueBeam machines.
Chang Z; Wu Q; Adamson J; Ren L; Bowsher J; Yan H; Thomas A; Yin FF
Med Phys; 2012 Nov; 39(11):6981-7018. PubMed ID: 23127092
[TBL] [Abstract][Full Text] [Related]
22. Telescopic measurements of backscattered radiation from secondary collimator jaws to a beam monitor chamber using a pair of slits.
Kubo H
Med Phys; 1989; 16(2):295-8. PubMed ID: 2497317
[TBL] [Abstract][Full Text] [Related]
23. Monte Carlo study of photon fields from a flattening filter-free clinical accelerator.
Vassiliev ON; Titt U; Kry SF; Pönisch F; Gillin MT; Mohan R
Med Phys; 2006 Apr; 33(4):820-7. PubMed ID: 16696457
[TBL] [Abstract][Full Text] [Related]
24. Dosimetry of the Siemens Mevatron 67 linear accelerator.
Horton JL
Int J Radiat Oncol Biol Phys; 1983 Aug; 9(8):1217-23. PubMed ID: 6409856
[TBL] [Abstract][Full Text] [Related]
25. A Monte Carlo study on internal wedges using BEAM.
van der Zee W; Welleweerd J
Med Phys; 2002 May; 29(5):876-85. PubMed ID: 12033584
[TBL] [Abstract][Full Text] [Related]
26. Extrafocal radiation: a unified approach to the prediction of beam penumbra and output factors for megavoltage x-ray beams.
Sharpe MB; Jaffray DA; Battista JJ; Munro P
Med Phys; 1995 Dec; 22(12):2065-74. PubMed ID: 8746712
[TBL] [Abstract][Full Text] [Related]
27. Measurement of backscattered radiation from secondary collimator jaws into the beam monitor chamber from a dual energy linear accelerator.
Ravikumar M; Ravichandran R
Strahlenther Onkol; 2001 Dec; 177(12):670-5. PubMed ID: 11789406
[TBL] [Abstract][Full Text] [Related]
28. A semianalytical method for the design of a linac x-ray beam flattening filter.
Flock ST; Shragge PC
Med Phys; 1987; 14(2):202-9. PubMed ID: 3587139
[TBL] [Abstract][Full Text] [Related]
29. Experimental determination of peripheral doses for different IMRT techniques delivered by a Siemens linear accelerator.
Wiezorek T; Voigt A; Metzger N; Georg D; Schwedas M; Salz H; Wendt TG
Strahlenther Onkol; 2008 Feb; 184(2):73-9. PubMed ID: 18259698
[TBL] [Abstract][Full Text] [Related]
30. X-ray beam characteristics of the Varian Clinac 6-100 linear accelerator.
Coffey CW; Beach JL; Thompson DJ; Mendiondo M
Med Phys; 1980; 7(6):716-22. PubMed ID: 7464718
[TBL] [Abstract][Full Text] [Related]
31. Magnetic analysis of the radiation components of a 10 MV photon beam.
Ling CC; Schell MC; Rustgi SN
Med Phys; 1982; 9(1):20-6. PubMed ID: 6804768
[TBL] [Abstract][Full Text] [Related]
32. Monte Carlo modeling and simulations of the High Definition (HD120) micro MLC and validation against measurements for a 6 MV beam.
Borges C; Zarza-Moreno M; Heath E; Teixeira N; Vaz P
Med Phys; 2012 Jan; 39(1):415-23. PubMed ID: 22225311
[TBL] [Abstract][Full Text] [Related]
33. Assessment of the setup dependence of detector response functions for mega-voltage linear accelerators.
Fox C; Simon T; Simon B; Dempsey JF; Kahler D; Palta JR; Liu C; Yan G
Med Phys; 2010 Feb; 37(2):477-84. PubMed ID: 20229856
[TBL] [Abstract][Full Text] [Related]
34. Radiation protection aspects of a new high-energy linear accelerator.
O'Brien P; Michaels HB; Gillies B; Aldrich JE; Andrew JW
Med Phys; 1985; 12(1):101-7. PubMed ID: 3919249
[TBL] [Abstract][Full Text] [Related]
35. Dosimetric considerations for a multileaf collimator system.
Palta JR; Yeung DK; Frouhar V
Med Phys; 1996 Jul; 23(7):1219-24. PubMed ID: 8839416
[TBL] [Abstract][Full Text] [Related]
36. Monte Carlo study of backscatter in a flattening filter free clinical accelerator.
Titt U; Vassiliev ON; Pönisch F; Kry SF; Mohan R
Med Phys; 2006 Sep; 33(9):3270-3. PubMed ID: 17022221
[TBL] [Abstract][Full Text] [Related]
37. Experimental investigation of the response of an a-Si EPID to an unflattened photon beam from an Elekta Precise linear accelerator.
Tyner E; McClean B; McCavana P; af Wetterstedt S
Med Phys; 2009 Apr; 36(4):1318-29. PubMed ID: 19472639
[TBL] [Abstract][Full Text] [Related]
38. Surface and buildup dose characteristics for 6, 10, and 18 MV photons from an Elekta Precise linear accelerator.
Klein EE; Esthappan J; Li Z
J Appl Clin Med Phys; 2003; 4(1):1-7. PubMed ID: 12540813
[TBL] [Abstract][Full Text] [Related]
39. Characteristics of the photon beam from a new 25-MV linear accelerator.
Aldrich JE; Andrew JW; Michaels HB; O'Brien PF
Med Phys; 1985; 12(5):619-24. PubMed ID: 4046997
[TBL] [Abstract][Full Text] [Related]
40. Practical dosimetric considerations of a 10-MV photon beam.
Van Dyk J
Med Phys; 1977; 4(2):145-53. PubMed ID: 403400
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]