41. The effect of heat and moisture exchanger and gas flow on humidity and temperature in a circle anaesthetic system. Poopalalingam R; Goh MH; Chan YW Singapore Med J; 2002 Nov; 43(11):563-5. PubMed ID: 12680524 [TBL] [Abstract][Full Text] [Related]
42. Fresh gas utilization of eight circle systems. Zbinden AM; Feigenwinter P; Hutmacher M Br J Anaesth; 1991 Oct; 67(4):492-9. PubMed ID: 1931411 [TBL] [Abstract][Full Text] [Related]
43. The circle system without absorber. Use with controlled ventilation. Snowdon SL; Powell DL; Fadl ET; Utting JE Anaesthesia; 1975 May; 30(3):323-32. PubMed ID: 1096653 [TBL] [Abstract][Full Text] [Related]
44. A comparison of the efficiency of three anesthesia circle systems. Harper M; Eger EI Anesth Analg; 1976; 55(5):724-9. PubMed ID: 987733 [TBL] [Abstract][Full Text] [Related]
45. The circle system as a humidifier. Bengtson JP; Bengtson A; Stenqvist O Br J Anaesth; 1989 Oct; 63(4):453-7. PubMed ID: 2818924 [TBL] [Abstract][Full Text] [Related]
52. Prediction of inspired oxygen concentration within a circle anaesthetic system. Raymond JA Br J Anaesth; 1976 Mar; 48(3):217-23. PubMed ID: 769810 [TBL] [Abstract][Full Text] [Related]
53. Global warming potential of inhaled anesthetics: application to clinical use. Ryan SM; Nielsen CJ Anesth Analg; 2010 Jul; 111(1):92-8. PubMed ID: 20519425 [TBL] [Abstract][Full Text] [Related]
54. Time to a 90% change in gas concentration: a comparison of three semi-closed anesthesia breathing systems. Dosch MP; Loeb RG; Brainerd TL; Stallwood JF; Lechner S Anesth Analg; 2009 Apr; 108(4):1193-7. PubMed ID: 19299785 [TBL] [Abstract][Full Text] [Related]
55. Control of end-tidal halothane concentration. Part A: Anaesthesia breathing system and feedback control of gas delivery. Westenskow DR; Zbinden AM; Thomson DA; Kohler B Br J Anaesth; 1986 May; 58(5):555-62. PubMed ID: 2938612 [TBL] [Abstract][Full Text] [Related]
56. Model for the administration of low-flow anaesthesia. Beams DM; Sasse FJ; Webster JG; Radwin RG Br J Anaesth; 1998 Aug; 81(2):161-70. PubMed ID: 9813516 [TBL] [Abstract][Full Text] [Related]
57. Association of partial pressure of carbon dioxide in expired gas and arterial blood at three different ventilation states in apneic chickens (Gallus domesticus) during air sac insufflation anesthesia. Paré M; Ludders JW; Erb HN Vet Anaesth Analg; 2013 May; 40(3):245-56. PubMed ID: 23331534 [TBL] [Abstract][Full Text] [Related]
58. Alveolar partial pressures of carbon dioxide and oxygen measured by a helium washout technique. Jordanoglou J; Tatsis G; Danos J; Gougoulakis S; Orfanidou D; Gaga M Thorax; 1990 Jul; 45(7):520-4. PubMed ID: 2118690 [TBL] [Abstract][Full Text] [Related]
59. [The temperature-humidity profile of the PhysioFlex. Studies on a model]. Wissing H; Kuhn I; Kessler P Anaesthesist; 1997 Mar; 46(3):201-6. PubMed ID: 9163264 [TBL] [Abstract][Full Text] [Related]
60. Comparison of the Bain and the ADE systems during controlled ventilation in adults. Shah NK; Loughlin CJ; Bedford RF Br J Anaesth; 1989 Feb; 62(2):150-2. PubMed ID: 2493798 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]