These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 6819848)

  • 1. Evaluation of extracranial carotid artery disease by ultrasonic duplex scanning: a clinical perspective.
    Chan A; Beach KW; Langlois Y; Roederer GO; Strandness DE
    Aust N Z J Surg; 1982 Dec; 52(6):562-9. PubMed ID: 6819848
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Noninvasive screening of extracranial carotid disease: duplex sonography with angiographic correlation.
    Clark WM; Hatten HP
    AJNR Am J Neuroradiol; 1981; 2(5):443-7. PubMed ID: 6792882
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ultrasonic duplex scanning for disease of the carotid artery.
    Fell G; Phillips DJ; Chikos PM; Harley JD; Thiele BL; Strandness DE
    Circulation; 1981 Dec; 64(6):1191-5. PubMed ID: 7296793
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of duplex Doppler scanning with contrast angiography in carotid artery disease.
    Barry R; Nel CJ
    S Afr Med J; 1987 Dec; 72(12):851-2. PubMed ID: 3424031
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of ulceration in the extracranial carotid artery with ultrasonography: a comparison with arteriography.
    Hansen F; Bergqvist D; Eriksson A; Maly P; Takolander R
    Eur J Vasc Surg; 1989 Oct; 3(5):443-8. PubMed ID: 2680611
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Symptomatic carotid ischaemic events: safest and most cost effective way of selecting patients for angiography, before carotid endarterectomy.
    Hankey GJ; Warlow CP
    BMJ; 1990 Jun; 300(6738):1485-91. PubMed ID: 2115384
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The impact of Duplex scanning on the evaluation of patients with asymptomatic bruits in the region of the carotid arteries.
    Breslau PJ; Phillips DJ; Greep JM; Strandness DE
    Neth J Surg; 1983 Sep; 35(4):134-8. PubMed ID: 6633924
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Importance of noninvasive ultrasonic-Doppler testing in the evaluation of patients with symptomatic carotid bruits.
    Fell G; Breslau P; Knox RA; Phillips D; Thiele BL; Strandness DE
    Am Heart J; 1981 Aug; 102(2):221-6. PubMed ID: 7258096
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Spiral computed tomography: a novel diagnostic approach for investigation of the extracranial cerebral arteries and its complementary role in duplex ultrasonography.
    Corti R; Ferrari C; Roberti M; Alerci M; Pedrazzi PL; Gallino A
    Circulation; 1998 Sep; 98(10):984-9. PubMed ID: 9737518
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Doppler spectrum analysis and traditional angiography in the study of the extracranial tract of the internal carotid artery].
    Cepich MS; Olivetti L; Sardo P; Floriani M; Bonardelli S; Giulini SM; Moretti R
    Radiol Med; 1987; 74(1-2):45-8. PubMed ID: 3303173
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Detection of carotid occlusive disease by ultrasonic imaging and pulsed Doppler spectrum analysis.
    Blackshear WM; Phillips DJ; Thiele BL; Hirsch JH; Chikos PM; Marinelli MR; Ward KJ; Strandness DE
    Surgery; 1979 Nov; 86(5):698-706. PubMed ID: 494062
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Accuracy and indications of diagnostic studies for extracranial carotid disease.
    Connolly JE; Brownell DA; Levine EF; McCart PM
    Arch Surg; 1985 Nov; 120(11):1229-32. PubMed ID: 3901958
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Duplex carotid sonography: criteria for stenosis, accuracy, and pitfalls.
    Jacobs NM; Grant EG; Schellinger D; Byrd MC; Richardson JD; Cohan SL
    Radiology; 1985 Feb; 154(2):385-91. PubMed ID: 3880910
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Duplex scanning of normal or minimally diseased carotid arteries: correlation with arteriography and clinical outcome.
    Zierler RE; Kohler TR; Strandness DE
    J Vasc Surg; 1990 Oct; 12(4):447-54; discussion 454-5. PubMed ID: 2214040
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Can carotid duplex scanning supplant arteriography in patients with focal carotid territory symptoms?
    Smith DC; Smith LL
    J Vasc Surg; 1987 Oct; 6(4):424-5. PubMed ID: 3309385
    [No Abstract]   [Full Text] [Related]  

  • 16. Screening of carotid arteries by noninvasive duplex scanning.
    Matsumoto GH; Rumwell CB
    Am J Surg; 1983 May; 145(5):609-10. PubMed ID: 6846698
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Noninvasive methods in the diagnosis of extracranial carotid artery disease: a correlation with carotid arteriography in eighty patients.
    Adiga KR; Fresso SJ; Nayden J
    Angiology; 1984 Jun; 35(6):331-40. PubMed ID: 6731943
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The limitations of diagnosis of carotid occlusion by Doppler ultrasound.
    Bornstein NM; Beloev ZG; Norris JW
    Ann Surg; 1988 Mar; 207(3):315-7. PubMed ID: 3278698
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The influence of ultrasonic Duplex scanning on the management of carotid artery disease.
    Breslau PJ; Knox RA; Greep JM; Strandness DE
    Br J Surg; 1983 May; 70(5):264-6. PubMed ID: 6850258
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of duplex scanning and contrast arteriography: a community hospital experience.
    Kenagy JW
    J Vasc Surg; 1985 Jul; 2(4):591-3. PubMed ID: 3892055
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.