These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 6829064)

  • 1. Rejection of prospective blood donors due to systematic errors in hematocrit measurement.
    Ross DG; Ross WB; Schreiner DE; Heaton WA
    Transfusion; 1983; 23(1):75-7. PubMed ID: 6829064
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Blood donor rejection rate: HemoCue hemoglobin analyzer vs. microhematocrit.
    Russell BL; Martin SM
    Clin Lab Sci; 1997; 10(6):321-4. PubMed ID: 10175331
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Second fingerstick: a simple method to increase the blood supply.
    Bravo J; Hsueh Y; Gordeuk V; Querin J; Brittenham G; Keating L
    Transfusion; 1990 Jun; 30(5):474-6. PubMed ID: 2360241
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The difference between fingerstick and venous hemoglobin and hematocrit varies by sex and iron stores.
    Cable RG; Steele WR; Melmed RS; Johnson B; Mast AE; Carey PM; Kiss JE; Kleinman SH; Wright DJ;
    Transfusion; 2012 May; 52(5):1031-40. PubMed ID: 22014071
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Red blood cell zinc protoporphyrin to evaluate anemia risk in deferred blood donors.
    Schifman RB; Rivers SL
    Am J Clin Pathol; 1987 Apr; 87(4):511-4. PubMed ID: 3826015
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of venipuncture blood counts with microcapillary measurements in screening for anemia in one-year-old infants.
    Thomas WJ; Collins TM
    J Pediatr; 1982 Jul; 101(1):32-5. PubMed ID: 7086621
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Predonation hematocrit measurement by whole blood electrical conductivity assay.
    Schifman RB; Rivers SL; Delduca M
    Transfusion; 1985; 25(3):251-3. PubMed ID: 4002310
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of two-step haemoglobin screening with HemoCue for blood donor qualification in mobile collection sites.
    Gómez-Simón A; Plaza EM; Torregrosa JM; Ferrer-Marín F; Sánchez-Guiu I; Vicente V; Lozano ML; Rivera J
    Vox Sang; 2014 Nov; 107(4):343-50. PubMed ID: 24916720
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Accuracy of predonation Hct sampling affects donor safety, eligibility, and deferral rates.
    Wood EM; Kim DM; Miller JP
    Transfusion; 2001 Mar; 41(3):353-9. PubMed ID: 11274589
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Volunteer blood donors who fail the copper sulfate screening test. What does failure mean, and what should be done?
    Lloyd H; Collins A; Walker W; Fail B; Hamilton PJ
    Transfusion; 1988; 28(5):467-9. PubMed ID: 3420676
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fingerstick blood samples in platelet donor screening: reliability and impact on predict yield programs.
    Randels MJ; Strauss RG; Raife TJ
    J Clin Apher; 1997; 12(3):105-9. PubMed ID: 9365861
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Hemoglobin screening in prospective blood donors: a comparison of methods.
    Avoy DR; Canuel ML; Otton BM; Mileski EB
    Transfusion; 1977; 17(3):261-4. PubMed ID: 867468
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Hemoglobin screening in prospective blood donors: comparison of different blood samples and different quantitative methods.
    Radtke H; Polat G; Kalus U; Salama A; Kiesewetter H
    Transfus Apher Sci; 2005 Aug; 33(1):31-5. PubMed ID: 15951241
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Fingerstick glucose determination in shock.
    Atkin SH; Dasmahapatra A; Jaker MA; Chorost MI; Reddy S
    Ann Intern Med; 1991 Jun; 114(12):1020-4. PubMed ID: 2029097
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Influence of climate on donor deferrals.
    Lau P; Hansen M; Sererat M
    Transfusion; 1988; 28(6):559-62. PubMed ID: 3194930
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of methods and protocols for hemoglobin screening of prospective whole blood donors.
    Chambers LA; McGuff JM
    Am J Clin Pathol; 1989 Mar; 91(3):309-12. PubMed ID: 2646909
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of hemoglobin of blood donors deferred by the copper sulphate method for hemoglobin estimation.
    Sawant RB; Bharucha ZS; Rajadhyaksha SB
    Transfus Apher Sci; 2007 Apr; 36(2):143-8. PubMed ID: 17382593
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Validity of arterial hematocrits in newborns.
    Stine MJ; Harris H
    Am J Dis Child; 1988 Jan; 142(1):66-7. PubMed ID: 3341301
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Population-based screening for anemia using first-time blood donors.
    Mast AE; Steele WR; Johnson B; Wright DJ; Cable RG; Carey P; Gottschall JL; Kiss JE; Simon TL; Murphy EL;
    Am J Hematol; 2012 May; 87(5):496-502. PubMed ID: 22460662
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Impact of changes to donor hemoglobin criteria on the rate of donor deferral.
    Perez GE; Gammon RR; Whitaker BI; Vassallo RR; Stubbs JR
    Transfusion; 2018 Nov; 58(11):2581-2588. PubMed ID: 30264396
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.