These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

107 related articles for article (PubMed ID: 6829783)

  • 21. [Peripheral blood flow measured by plethysmography with venous occlusion in patients with mitral stenosis].
    Evora PR; Godoy RA; Cherri J; Carneiro JJ; Vicente WV; Otaviano AG; Sader AA
    Arq Bras Cardiol; 1982 Jun; 38(6):459-63. PubMed ID: 7168676
    [No Abstract]   [Full Text] [Related]  

  • 22. Venous occlusion plethysmography using a fiber-optic sensor.
    Stenow EN; Oberg PA
    IEEE Trans Biomed Eng; 1993 Mar; 40(3):284-9. PubMed ID: 8335332
    [TBL] [Abstract][Full Text] [Related]  

  • 23. The influence of limb elevation, examination technique, and outflow system design on venous plethysmography.
    Tripolitis AJ; Blackshear WM; Bodily KC; Thiele BL; Strandness DE
    Angiology; 1980 Mar; 31(3):154-63. PubMed ID: 7369546
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Continuous limb blood flow estimation in the newborn using electrical impedance plethysmography.
    Costeloe K; Rolfe P
    Pediatr Res; 1980 Sep; 14(9):1053-60. PubMed ID: 7454446
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Study of peripheral blood circulation using automated occlusion plethysmography].
    Mukharliamov NM; Sazonova LN; Pushkar' IuT
    Ter Arkh; 1981; 53(12):3-6. PubMed ID: 7336338
    [No Abstract]   [Full Text] [Related]  

  • 26. Pitfall of venous occlusion plethysmography.
    Knox R; Cramer M; Fell G; Breslau P; Beach K; Strandness DE
    Angiology; 1982 Apr; 33(4):268-76. PubMed ID: 7073019
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Measurement of limb venous compliance in humans: technical considerations and physiological findings.
    Halliwill JR; Minson CT; Joyner MJ
    J Appl Physiol (1985); 1999 Oct; 87(4):1555-63. PubMed ID: 10517791
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Use of an automated venous occlusion plethysmograph for late postoperative studies on the arterial blood flow of the leg after use of the external iliac artery for retrograde perfusion].
    Hutschenreiter W; Weissbach G; Kraft W
    Z Exp Chir; 1978; 11(5):312-6. PubMed ID: 735262
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A comparison of the strain-gauge and the Dohn air-filled plethysmographs for blood flow measurements in the human calf.
    Eickhoff JH; Kjaer L; Siggaard-Andersen J
    Acta Chir Scand Suppl; 1980; 502():15-20. PubMed ID: 6941591
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Influence of tissue compressibility on calibration for strain-gauge plethysmography.
    Brengelmann GL; Savage M
    J Appl Physiol (1985); 1986 Sep; 61(3):1210-6. PubMed ID: 3759760
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Beat-by-beat forearm blood flow with Doppler ultrasound and strain-gauge plethysmography.
    Tschakovsky ME; Shoemaker JK; Hughson RL
    J Appl Physiol (1985); 1995 Sep; 79(3):713-9. PubMed ID: 8567508
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [New plethysmography for measuring limb blood flow using RI].
    Fukuoka M; Kawakami K; Shimada T; Kobori K; Yamakoshi K; Shimazu H; Ito H
    Iyodenshi To Seitai Kogaku; 1983 Aug; 21(4):252-5. PubMed ID: 6668735
    [No Abstract]   [Full Text] [Related]  

  • 33. Assessment of the peripheral microcirculation using computer-assisted venous congestion plethysmography in post-traumatic complex regional pain syndrome type I.
    Schürmann M; Zaspel J; Gradl G; Wipfel A; Christ F
    J Vasc Res; 2001; 38(5):453-61. PubMed ID: 11561147
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [Sequelae of unilateral deep venous thrombosis in plethysmography of the calf].
    Zicot M; Depairon M
    J Mal Vasc; 1982; 7(3):205-8. PubMed ID: 7142824
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Blood supply measurement of the extremities, estimation of microcirculation and heart circulation screening with an occluded vein plethysmographic method. III. Instructions for occluded vein plethysmography investigations].
    Hackel F
    Z Arztl Fortbild (Jena); 1975 Oct; 69(19):1033-5. PubMed ID: 1210396
    [No Abstract]   [Full Text] [Related]  

  • 36. Description and validation of a novel liquid metal-free device for venous congestion plethysmography.
    Christ F; Bauer A; Brügger D; Niklas M; Gartside IB; Gamble J
    J Appl Physiol (1985); 2000 Oct; 89(4):1577-83. PubMed ID: 11007598
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Extremity blood flow in man: comparison between strain-gauge and capacitance plethysmography.
    Dresler CM; Jeevanandam M; Brennan MF
    Surgery; 1987 Jan; 101(1):35-9. PubMed ID: 3798325
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Detection of deep vein thrombosis with an automatic electrically calibrated strain gauge plethysmograph.
    Barnes RW; Hokanson DE; Wu KK; Hoak JC
    Surgery; 1977 Aug; 82(2):219-23. PubMed ID: 877865
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Plethysmographic investigation into the increase in limb muscle blood flow following constriction of skin vessels.
    COYER AB
    Ann Phys Med; 1954 Oct; 2(4):128-31. PubMed ID: 13229231
    [No Abstract]   [Full Text] [Related]  

  • 40. The effect of changing limb position on the validity of venous occlusion plethysmography.
    Rojek AM; Wood RE; Stewart IB
    Physiol Meas; 2007 Aug; 28(8):861-7. PubMed ID: 17664678
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.