These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 683153)

  • 21. [X-rays: filiform anticathodes].
    BARRAUD J
    C R Hebd Seances Acad Sci; 1952 Feb; 234(6):614-6. PubMed ID: 12979214
    [No Abstract]   [Full Text] [Related]  

  • 22. An experimental x-ray shadow microscope.
    COSSLETT VE; NIXON WC
    Proc R Soc Lond B Biol Sci; 1952 Nov; 140(900):422-31. PubMed ID: 13003938
    [No Abstract]   [Full Text] [Related]  

  • 23. Principles of digital radiography with large-area, electronically readable detectors: a review of the basics.
    Chotas HG; Dobbins JT; Ravin CE
    Radiology; 1999 Mar; 210(3):595-9. PubMed ID: 10207454
    [No Abstract]   [Full Text] [Related]  

  • 24. [Layout for the control of the radiation and electrical characteristics of UKREKH X-ray apparatus].
    Berdiakov GI
    Med Tekh; 2002; (5):18-21. PubMed ID: 12512277
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Experience with a new simplified Siemens attachment for x-ray demonstration of the heart and great vessels].
    HOCKERTS T
    Munch Med Wochenschr; 1952 Dec; 94(49):2488-90. PubMed ID: 13025429
    [No Abstract]   [Full Text] [Related]  

  • 26. An electronic instrument for indirectly determining the peak kilovoltage of diagnostic X-ray machines.
    Putney RG; Raymond DM
    Phys Med Biol; 1984 Jan; 29(1):45-52. PubMed ID: 6701192
    [No Abstract]   [Full Text] [Related]  

  • 27. Performance characteristics of a pulsed plasma cathode X-ray source operated without diode closure.
    Kashiwabara S; Watanabe K; Fujimoto R
    Med Biol Eng Comput; 1994 Sep; 32(5):580-4. PubMed ID: 7845077
    [No Abstract]   [Full Text] [Related]  

  • 28. Solid-state, flat-panel, digital radiography detectors and their physical imaging characteristics.
    Cowen AR; Kengyelics SM; Davies AG
    Clin Radiol; 2008 May; 63(5):487-98. PubMed ID: 18374710
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [A radiation method of determining the voltage of x-ray radiation generation. Its status and the outlook].
    Vladimirov LV; Kozlov AA; Lygin VA; Riabkin AN
    Med Tekh; 2000; (5):15-9. PubMed ID: 11076358
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Technical Note: Nanometric organic photovoltaic thin film detectors for dose monitoring in diagnostic x-ray imaging.
    Elshahat B; Gill HS; Filipyev I; Shrestha S; Hesser J; Kumar J; Karellas A; Zygmanski P; Sajo E
    Med Phys; 2015 Jul; 42(7):4027-32. PubMed ID: 26133603
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Equipment for microradiography with soft roentgen rays.
    ENGSTROM A; WEGSTEDT L
    Acta Radiol (Stockh); 1951; 35(5-6):345-55. PubMed ID: 14868537
    [No Abstract]   [Full Text] [Related]  

  • 32. Checking X-ray beam field size.
    Crooks HE; Ardran GM
    Radiography; 1976 Nov; 42(503):239-40. PubMed ID: 1005669
    [No Abstract]   [Full Text] [Related]  

  • 33. [Registration of failures (defects) in electric circuits of the x-ray apparatus].
    Tretiakov VV
    Med Tekh; 1975; (2):32-4. PubMed ID: 1226093
    [No Abstract]   [Full Text] [Related]  

  • 34. Kilovoltage peak and half value layer relationships of a dental X-ray machine.
    Patel JR
    Indian J Dent Res; 1992; 3(2):31-5. PubMed ID: 1343955
    [TBL] [Abstract][Full Text] [Related]  

  • 35. An investigation of the shielding characteristics of computed radiography cassettes.
    Potts R; Baker K; Bridge L
    Br J Radiol; 2008 Feb; 81(962):151-3. PubMed ID: 18238923
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A new high-definition microfocal X-ray unit.
    Buckland-Wright JC
    Br J Radiol; 1989 Mar; 62(735):201-8. PubMed ID: 2702377
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Test cassette for measuring peak tube potential of diagnostic x-ray machines.
    Jacobson AF; Cameron JR; Siedband MP; Wagner J
    Med Phys; 1976; 3(1):. PubMed ID: 1256375
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Performance characteristics of X-ray tubes and generators.
    Harrison RM; Forster E
    Radiography; 1984; 50(594):245-8. PubMed ID: 6505169
    [No Abstract]   [Full Text] [Related]  

  • 39. [A novel voltage multiplier for X-ray power supply].
    Tang Z; Yang H; Wang G; Zhang Z
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2011 Oct; 28(5):946-50. PubMed ID: 22097261
    [TBL] [Abstract][Full Text] [Related]  

  • 40. X-ray imaging using amorphous selenium: photoinduced discharge (PID) readout for digital general radiography.
    Rowlands JA; Hunter DM
    Med Phys; 1995 Dec; 22(12):1983-96. PubMed ID: 8746703
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.