These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

180 related articles for article (PubMed ID: 6835050)

  • 1. [Comparison of the results of measuring the dosage in fast neutron fields on nuclear physics installations].
    Kapchigashev SP; Kudriashov EI; Masliaev PF; Nazarov VM; Obaturov GM
    Med Radiol (Mosk); 1983 Feb; 28(2):65-8. PubMed ID: 6835050
    [No Abstract]   [Full Text] [Related]  

  • 2. Optimization of fast neutron spectra available for neutron capture therapy.
    Pfister G; Hehn G; el-Husseini F
    Strahlenther Onkol; 1989; 165(2-3):107-9. PubMed ID: 2494709
    [No Abstract]   [Full Text] [Related]  

  • 3. [Experience with neutron teletherapy of malignant tumors].
    Zyrianov BN; Musabaeva LI; Lisin VA; Letov VN; Didenko AN
    Vopr Onkol; 1987; 33(6):71-6. PubMed ID: 3617603
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Impact of the introduction of ICRP Publication 103 on neutron dosimetry.
    Sato T; Endo A; Yasuda H; Niita K
    Radiat Prot Dosimetry; 2011 Jul; 146(1-3):183-5. PubMed ID: 21493604
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Physical and radiobiological characteristics of the U-120 cyclotron fast neutron beam].
    Letov VN; Fesenko VV; Ievlev SM; Bel'skiĭ EM; Driapachenko IP
    Med Radiol (Mosk); 1977 Oct; 22(10):34-40. PubMed ID: 916836
    [No Abstract]   [Full Text] [Related]  

  • 6. Energy and direction distribution of neutrons in workplace fields: implication of the results from the EVIDOS project for the set-up of simulated workplace fields.
    Luszik-Bhadra M; Lacoste V; Reginatto M; Zimbal A
    Radiat Prot Dosimetry; 2007; 126(1-4):151-4. PubMed ID: 17519241
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Dosimetric and radiobiological characteristics of the radiation field from the reaction d(50 MeV)--Be].
    Bukanov VN; Kataevskiĭ IuF; Indyk VM; Chebotarev EE; Tkachenko NA
    Radiobiologiia; 1983; 23(5):709-11. PubMed ID: 6647788
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Neutron measurements in Spanish nuclear power plants with a Bonner sphere spectrometer system.
    Fernández F; Domingo C; Amgarou K; Bouassoule T; García MJ
    Radiat Prot Dosimetry; 2007; 126(1-4):355-60. PubMed ID: 17525063
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Results of field trials using the NPL simulated reactor neutron field facility.
    Taylor GC; Thomas DJ; Bennett A
    Radiat Prot Dosimetry; 2007; 126(1-4):89-92. PubMed ID: 17848380
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Leakage neutrons produced by 10MeV medical accelerators.
    McGinley PH; Fenn JO; White TA
    Health Phys; 1979 May; 36(5):635-7. PubMed ID: 114506
    [No Abstract]   [Full Text] [Related]  

  • 11. Measurement of the fast neutron flux in the MNSR inner irradiation site.
    Khattab K
    Appl Radiat Isot; 2007 Jan; 65(1):46-9. PubMed ID: 16973369
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Sources of fast neutrons in medicine].
    Vincour J; Bém P
    Cesk Radiol; 1988 Mar; 42(2):118-27. PubMed ID: 3365819
    [No Abstract]   [Full Text] [Related]  

  • 13. Nuclear accident dosimetry: calculations and comparison with experimental data.
    Santoro RT; Alsmiller RG; Barnes JM
    Health Phys; 1979 Feb; 36(2):189-91. PubMed ID: 478874
    [No Abstract]   [Full Text] [Related]  

  • 14. The problems associated with the monitoring of complex workplace radiation fields at European high-energy accelerators and thermonuclear fusion facilities.
    Bilski P; Blomgren J; d'Errico F; Esposito A; Fehrenbacher G; Fernàndez F; Fuchs A; Golnik N; Lacoste V; Leuschner A; Sandri S; Silari M; Spurny F; Wiegel B; Wright P
    Radiat Prot Dosimetry; 2007; 126(1-4):491-6. PubMed ID: 17496292
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development of a quasi-monoenergetic neutron field using the 7Li(p,n)7Be reaction in the energy range from 250 to 390 MeV at RCNP.
    Taniguchi S; Nakao N; Nakamura T; Yashima H; Iwamoto Y; Satoh D; Nakane Y; Nakashima H; Itoga T; Tamii A; Hatanaka K
    Radiat Prot Dosimetry; 2007; 126(1-4):23-7. PubMed ID: 17502318
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A comparison of different recombination methods in mixed radiation fields at high energy accelerators.
    Zielczynski M; Golnik N; Gryzinski MA
    Radiat Prot Dosimetry; 2007; 126(1-4):248-52. PubMed ID: 17575296
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Relative measurements of fast neutron contamination in 18-MV photon beams from two linear accelerators and a betatron.
    Gur D; Bukovitz G; Rosen JC; Holmes BG
    Med Phys; 1979; 6(2):140-1. PubMed ID: 460063
    [TBL] [Abstract][Full Text] [Related]  

  • 18. High-energy response of the PRESCILA and WENDI-II neutron rem meters.
    Olsher RH; McLean TD
    Radiat Prot Dosimetry; 2008; 130(4):510-3. PubMed ID: 18381335
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Performance of a PADC personal neutron dosemeter at simulated and real workplace fields of the nuclear industry.
    Fiechtner A; Boschung M; Wernli C
    Radiat Prot Dosimetry; 2007; 126(1-4):314-7. PubMed ID: 17578876
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Study and presentation of a fast neutron and photon dosemeter for area and criticality monitoring using radiophotoluminescent glass.
    Girod M; Bourgois L; Cornillaux G; Andre S; Postaük J
    Radiat Prot Dosimetry; 2004; 112(3):359-70. PubMed ID: 15537662
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.