BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 6847294)

  • 1. Unusual complication of porcine heterograft.
    Sarabu MR; Parker FB
    Ann Thorac Surg; 1983 May; 35(5):553-5. PubMed ID: 6847294
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Calcific stenosis of the porcine heterograft.
    Lamberti JJ; Wainer BH; Fisher KA; Karunaratne HB; Al-Sadir J
    Ann Thorac Surg; 1979 Jul; 28(1):28-32. PubMed ID: 454040
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Early calcification and obstruction of a mitral porcine bioprosthesis.
    Lewis BS; Bakst A; Rod JL; Rein A; Gotsman MS; Appelbaum A
    Ann Thorac Surg; 1980 Dec; 30(6):592-4. PubMed ID: 7469580
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [A "cooing murmur" in insufficiency of a xenograft valve].
    Arikawa K; Saigenji H; Morishita Y; Takenaka K; Taira A; Tei C; Kisanuki A
    Kyobu Geka; 1986 Jun; 39(6):495-8. PubMed ID: 3747289
    [No Abstract]   [Full Text] [Related]  

  • 5. Complete Transcatheter Treatment of Degenerated Bioprosthetic Mitral Regurgitation: Transapical Paravalvular Leak Closure Followed by Transseptal Mitral Valve-in-Valve Replacement.
    Singh GD; Smith TW; Boyd WD; Southard JA; Wong GB; Philip F; Low RI; Rogers JH
    JACC Cardiovasc Interv; 2015 Dec; 8(14):e229-31. PubMed ID: 26604059
    [No Abstract]   [Full Text] [Related]  

  • 6. Unexpected long durability of a low-profile porcine Liotta bioprosthesis in mitral position.
    Campanella A; Comoglio C; Sansone F; Rinaldi M
    J Cardiovasc Med (Hagerstown); 2009 Jun; 10(6):492-3. PubMed ID: 19346969
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An important complication of Hancock mitral valve replacement in children.
    Kutsche LM; Oyer P; Shumway N; Baum D
    Circulation; 1979 Aug; 60(2 Pt 2):98-103. PubMed ID: 445780
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Production of abnormal systolic sounds by vibration of torn leaflet of porcine xenograft.
    Come PC
    Arch Intern Med; 1983 Apr; 143(4):801-3. PubMed ID: 6188421
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Acute dysfunction of mitral bioprosthesis: Doppler expression of a musical holosystolic murmur. Apropos of 2 cases].
    Metz D; Laudinat JM; Chapoutot L; Taupin JM; Chabert JP; Pollet E; Bajolet A
    Arch Mal Coeur Vaiss; 1989 Sep; 82(9):1617-21. PubMed ID: 2510682
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An unusual complication associated with the Carpentier-Edwards porcine bioprosthesis.
    Misawa Y; Oki SI; Tezuka Y; Fuse K
    ASAIO J; 2001; 47(5):563-4. PubMed ID: 11575838
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Severe and early stenosis of porcine heterograft mitral valve.
    Forfar JC; Cotter L; Morritt GN
    Br Heart J; 1978 Oct; 40(10):1184-7. PubMed ID: 568477
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Early pericardial valve deterioration as a result of adhesions with native mitral valve.
    Rohn V; Spacek M; Sachl R; Vitkova I
    Ann Thorac Surg; 2014 Jul; 98(1):321-3. PubMed ID: 24996713
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Clinical and haemodynamic evaluation of mounted porcine heterograft in mitral position.
    Cotter L; Miller HC
    Br Heart J; 1979 Apr; 41(4):412-7. PubMed ID: 465209
    [No Abstract]   [Full Text] [Related]  

  • 14. Microangiopathic hemolytic anemia as the initial manifestation of porcine valve failure.
    Enzenauer RJ; Berenberg JL; Cassell PF
    South Med J; 1990 Aug; 83(8):912-7. PubMed ID: 2200135
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Structural valve deterioration of porcine bioprosthesis soon after mitral valve repair and replacement.
    Takano T; Seto T; Asaka S; Terasaki T; Ohashi N; Fukui D; Amano J
    Ann Thorac Cardiovasc Surg; 2014; 20 Suppl():717-9. PubMed ID: 23666245
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Severe regurgitation immediately after replacement of a dysfunctional bioprosthesis in the mitral valve position.
    Farooq H; Grayburn P; Roberts WC
    Am J Cardiol; 2005 Mar; 95(5):703-4. PubMed ID: 15721129
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Hemolytic anemia secondary to a porcine mitral prosthetic valve leaflet dissection.
    Brown MR; Hasaniya NW; Dang CR
    Ann Thorac Surg; 1995 Jun; 59(6):1573-4. PubMed ID: 7771848
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Transseptal Transcatheter Implantation of a Third-Generation Balloon-Expandable Valve in Degenerated Mitral Bioprosthesis.
    Jochheim D; Khandoga A; Bauer A; Baquet M; Theiss H; Schenzle J; Hausleiter J; Massberg S; Mehilli J
    JACC Cardiovasc Interv; 2015 Dec; 8(14):e241-3. PubMed ID: 26718526
    [No Abstract]   [Full Text] [Related]  

  • 19. Delayed rupture of the left ventricle after mitral valve replacement with bioprosthesis.
    Nuñez L; Gil-Aguado M; Cerron M; Celemin P
    Ann Thorac Surg; 1979 May; 27(5):465-7. PubMed ID: 454021
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Late-occurrence hemolytic anemia after mitral valve bioprosthesis. 2 cases].
    Piquemal R; Fauchier L; Regimbeau C; Babuty D; Neville P; Renard JP
    Arch Mal Coeur Vaiss; 1998 Jul; 91(7):879-81. PubMed ID: 9749180
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.