132 related articles for article (PubMed ID: 6847348)
1. Animal experiments to examine the histology of fracture healing in osteosynthesis with external fixation and compression.
Mayer G; Wolf E
Arch Orthop Trauma Surg (1978); 1983; 101(2):111-20. PubMed ID: 6847348
[TBL] [Abstract][Full Text] [Related]
2. [Experimental studies in animals on interfragmentary pressure in osteosyntheses with external bone fixation and compression (author's transl)].
Mayer G
Z Orthop Ihre Grenzgeb; 1980; 118(3):311-9. PubMed ID: 7415425
[TBL] [Abstract][Full Text] [Related]
3. Dynamization at the near cortex in locking plate osteosynthesis by means of dynamic locking screws: an experimental study of transverse tibial osteotomies in sheep.
Richter H; Plecko M; Andermatt D; Frigg R; Kronen PW; Klein K; Nuss K; Ferguson SJ; Stöckle U; von Rechenberg B
J Bone Joint Surg Am; 2015 Feb; 97(3):208-15. PubMed ID: 25653321
[TBL] [Abstract][Full Text] [Related]
4. Shear movement at the fracture site delays healing in a diaphyseal fracture model.
Augat P; Burger J; Schorlemmer S; Henke T; Peraus M; Claes L
J Orthop Res; 2003 Nov; 21(6):1011-7. PubMed ID: 14554213
[TBL] [Abstract][Full Text] [Related]
5. Comparison of unreamed nailing and external fixation of tibial diastases--mechanical conditions during healing and biological outcome.
Klein P; Opitz M; Schell H; Taylor WR; Heller MO; Kassi JP; Kandziora F; Duda GN
J Orthop Res; 2004 Sep; 22(5):1072-8. PubMed ID: 15304281
[TBL] [Abstract][Full Text] [Related]
6. Intramedullary cement osteosynthesis (IMCO): a pilot study in sheep.
Mirzasadeghi A; Narayanan SS; Ng MH; Sanaei R; Cheng CH; Bajuri MY; Shukur MH
Biomed Mater Eng; 2014; 24(6):2177-86. PubMed ID: 25226916
[TBL] [Abstract][Full Text] [Related]
7. A radiological and histological analysis of fracture healing using prebending of compression plates.
Nunamaker DM; Perren SM
Clin Orthop Relat Res; 1979; (138):167-74. PubMed ID: 445897
[TBL] [Abstract][Full Text] [Related]
8. Combination of interfragmentary screws and locking plates in distal meta-diaphyseal fractures of the tibia: a retrospective, single-centre pilot study.
Horn C; Döbele S; Vester H; Schäffler A; Lucke M; Stöckle U
Injury; 2011 Oct; 42(10):1031-7. PubMed ID: 21663909
[TBL] [Abstract][Full Text] [Related]
9. Interfragmentary movements in the early phase of healing in distraction and correction osteotomies stabilized with ring fixators.
Duda GN; Sporrer S; Sollmann M; Hoffmann JE; Kassi JP; Khodadadyan C; Raschke M
Langenbecks Arch Surg; 2003 Feb; 387(11-12):433-40. PubMed ID: 12607125
[TBL] [Abstract][Full Text] [Related]
10. Tibial shaft fractures. A comparison of conservative treatment and internal fixation with conventional plates or AO compression plates.
Jensen JS; Hansen FW; Johansen J
Acta Orthop Scand; 1977; 48(2):204-12. PubMed ID: 868506
[TBL] [Abstract][Full Text] [Related]
11. To fix or not to fix? The role of fibular fixation in distal shaft fractures of the leg.
Berlusconi M; Busnelli L; Chiodini F; Portinaro N
Injury; 2014 Feb; 45(2):408-11. PubMed ID: 24129327
[TBL] [Abstract][Full Text] [Related]
12. Interfragmentary motion in tibial osteotomies stabilized with ring fixators.
Duda GN; Sollmann M; Sporrer S; Hoffmann JE; Kassi JP; Khodadadyan C; Raschke M
Clin Orthop Relat Res; 2002 Mar; (396):163-72. PubMed ID: 11859239
[TBL] [Abstract][Full Text] [Related]
13. [Healing of spiral fractures in the sheep tibia comparing different methods--osteosynthesis with internal fixation, interlocking nailing and dynamic compression plate].
Seibold R; Schlegel U; Kessler SB; Cordey J; Perren SM; Schweiberer L
Unfallchirurg; 1995 Dec; 98(12):620-6. PubMed ID: 8584943
[TBL] [Abstract][Full Text] [Related]
14. Fixation technique influences osteogenesis of comminuted fractures.
Claes L; Heitemeyer U; Krischak G; Braun H; Hierholzer G
Clin Orthop Relat Res; 1999 Aug; (365):221-9. PubMed ID: 10627706
[TBL] [Abstract][Full Text] [Related]
15. Timely fracture-healing requires optimization of axial fixation stability.
Epari DR; Kassi JP; Schell H; Duda GN
J Bone Joint Surg Am; 2007 Jul; 89(7):1575-85. PubMed ID: 17606797
[TBL] [Abstract][Full Text] [Related]
16. Healing of rabbit tibial fractures using external fixation. Effects of removal of the fixation device.
Terjesen T
Acta Orthop Scand; 1984 Apr; 55(2):192-6. PubMed ID: 6711288
[TBL] [Abstract][Full Text] [Related]
17. [Histologic finding of fracture healing using external fixation and its clinical significance].
Stürmer KM
Unfallchirurgie; 1984 Jun; 10(3):110-22. PubMed ID: 6474602
[TBL] [Abstract][Full Text] [Related]
18. The influence of different osteosynthesis configurations with locking compression plates (LCP) on stability and fracture healing after an oblique 45° angle osteotomy.
Plecko M; Lagerpusch N; Pegel B; Andermatt D; Frigg R; Koch R; Sidler M; Kronen P; Klein K; Nuss K; Gedet P; Bürki A; Ferguson SJ; Stoeckle U; Auer JA; von Rechenberg B
Injury; 2012 Jul; 43(7):1041-51. PubMed ID: 22284334
[TBL] [Abstract][Full Text] [Related]
19. Operative treatment of tibial shaft fractures: a comparison of different methods of primary stabilisation.
Beardi J; Hessmann M; Hansen M; Rommens PM
Arch Orthop Trauma Surg; 2008 Jul; 128(7):709-15. PubMed ID: 18465138
[TBL] [Abstract][Full Text] [Related]
20. Combined internal and external osteosynthesis a biological approach to the treatment of complex fractures of the proximal tibia.
Gerber A; Ganz R
Injury; 1998; 29 Suppl 3():C22-8. PubMed ID: 10341894
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]