56 related articles for article (PubMed ID: 684786)
1. Absorbed dose distributions for electron beams from the sagittaire. Systematic measurements and their representation for introduction into a computer.
Tronc D; Levaillant M
Strahlentherapie; 1978 Sep; 154(9):643-9. PubMed ID: 684786
[TBL] [Abstract][Full Text] [Related]
2. Absorbed dose distributions for X-ray beams and beams of electrons from the Therac 20 Saturne linear accelerator.
Tronc D; Noël A
Strahlentherapie; 1978 Nov; 154(11):780-5. PubMed ID: 715810
[TBL] [Abstract][Full Text] [Related]
3. Comparison between experimental measurements and calculated transport simulation for electron dose distributions inside homogeneous phantoms.
Borrell-Carbonell A; Patau JP; Terrissol M; Tronc D
Strahlentherapie; 1980 Mar; 156(3):186-91. PubMed ID: 7361334
[TBL] [Abstract][Full Text] [Related]
4. Measurements on the radiation protection of patients irradiated with an 18-MeV electron linear accelerator.
Nüsslin F; Hassenstein E
Strahlentherapie; 1980 Feb; 156(2):120-4. PubMed ID: 7355412
[TBL] [Abstract][Full Text] [Related]
5. Absorbed dose distribution for X-ray beams and beams of electrons from the Therac 10 Neptune linear accelerator.
Tronc D; Gayet P
Strahlentherapie; 1980 Feb; 156(2):125-8. PubMed ID: 7355413
[TBL] [Abstract][Full Text] [Related]
6. [Dosimetry of high energy electron beams from a linear accelerator (author's transl)].
Briot E; Dutreix A
J Radiol Electrol Med Nucl; 1976 May; 57(5):447-54. PubMed ID: 994092
[TBL] [Abstract][Full Text] [Related]
7. Calculation of high-energy electron dose distributions in tissue-equivalent media. I. Determination of the dose function of point unidirectional sources.
Kozlov AP; Shishov VA
Strahlentherapie; 1982 May; 158(5):298-304. PubMed ID: 7112625
[TBL] [Abstract][Full Text] [Related]
8. Absorbed dose from contaminant electrons inside and outside megavoltage photon beams.
Raffaele L; Ielo I; Settineri N; Tosi G; Brambilla MG; Cattani F
Radiol Med; 1993 Oct; 86(4):513-20. PubMed ID: 8248591
[TBL] [Abstract][Full Text] [Related]
9. Validation of calculations for electrons modulated with conventional photon multileaf collimators.
Klein EE; Vicic M; Ma CM; Low DA; Drzymala RE
Phys Med Biol; 2008 Mar; 53(5):1183-208. PubMed ID: 18296757
[TBL] [Abstract][Full Text] [Related]
10. Dosimetric characteristics of electron beams produced by a mobile accelerator for IORT.
Pimpinella M; Mihailescu D; Guerra AS; Laitano RF
Phys Med Biol; 2007 Oct; 52(20):6197-214. PubMed ID: 17921580
[TBL] [Abstract][Full Text] [Related]
11. [Total skin therapy with electron beams. I. Physical and geometric factors].
Ragona R; Anglesio S; Madon E; Urgesi A; Rampino M; Monetti U
Radiol Med; 1990 Oct; 80(4 Suppl 1):151-4. PubMed ID: 2251408
[TBL] [Abstract][Full Text] [Related]
12. Charge collection efficiency in ionization chambers exposed to electron beams with high dose per pulse.
Laitano RF; Guerra AS; Pimpinella M; Caporali C; Petrucci A
Phys Med Biol; 2006 Dec; 51(24):6419-36. PubMed ID: 17148826
[TBL] [Abstract][Full Text] [Related]
13. Certain dosimetric features of electrons from a CGR Therac-20 MeV Saturne linear accelerator.
Nair RP
Strahlentherapie; 1985 Mar; 161(3):154-6. PubMed ID: 3919472
[TBL] [Abstract][Full Text] [Related]
14. Dose distribution of therapeutic electron beams and automation of treatment planning.
Osman G
J Med; 1976; 7(2):143-67. PubMed ID: 1064682
[TBL] [Abstract][Full Text] [Related]
15. [Dosimetry problems of radiotherapy with electron fields of small dimension or partially shielded].
Begnozzi L; Arcangeli G; Giovinazzo G; Franceschelli L; Bianciardi L; Benassi M
Radiol Med; 1990 Oct; 80(4 Suppl 1):37-42. PubMed ID: 2251416
[TBL] [Abstract][Full Text] [Related]
16. [Distribution of absorbed dose of electron beams from a linear accelerator of 8-17.5 MeV energy].
Kozlov AP; Afanas'ev BP; Ershov AT; Likhtarev MI; Regel' AV
Med Radiol (Mosk); 1987 Apr; 32(4):65-71. PubMed ID: 3586912
[TBL] [Abstract][Full Text] [Related]
17. Comparison of electron beams from the Siemens betatron and the Sagittaire linear accelerator.
de Almeida CE; Almond PR
Radiology; 1974 May; 111(2):439-45. PubMed ID: 4206558
[No Abstract] [Full Text] [Related]
18. [Criteria for the optimization of geometrical dose distributions in radiotherapy (author's transl)].
Wendhausen H
Strahlentherapie; 1979 Apr; 155(4):254-7. PubMed ID: 452051
[TBL] [Abstract][Full Text] [Related]
19. Electron beam dose planning using discrete Gaussian beams. Mathematical background.
Brahme A; Lax I; Andreo P
Acta Radiol Oncol; 1981; 20(2):147-58. PubMed ID: 6270968
[TBL] [Abstract][Full Text] [Related]
20. Perturbation of isodose distributions adjacent to cavities in tissue-equivalent media during irradiation by 10-35 MeV electrons.
Starchman DE; Chao JH
Radiology; 1972 Jul; 104(1):177-86. PubMed ID: 5033582
[No Abstract] [Full Text] [Related]
[Next] [New Search]