These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

166 related articles for article (PubMed ID: 6852648)

  • 1. Effects of temperature on arterial and cutaneous pO2 in the rabbit.
    Silverman F; Young BK
    Gynecol Obstet Invest; 1983; 15(5):283-90. PubMed ID: 6852648
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of continuous transcutaneous Po2 measurement with intermittent arterial Po2 determinations in fetal lambs.
    Mueller-Heubach E; Caritis SN; Edelstone DI; Huch R; Huch A
    Obstet Gynecol; 1981 Feb; 57(2):248-52. PubMed ID: 7465132
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A comparative study of continuous intravascular O2 saturation and transcutaneous PO2 measurements in the sheep fetus following the reduction of uterine blood flow.
    Künzel W; Kastendieck E; Kurz CS
    Birth Defects Orig Artic Ser; 1979; 15(4):591-7. PubMed ID: 534744
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Transcutaneous oxygen pressure measured at two different electrode core temperatures in healthy volunteers and patients with arterial occlusive disease.
    Creutzig A; Dau D; Caspary L; Alexander K
    Int J Microcirc Clin Exp; 1987; 5(4):373-80. PubMed ID: 3557822
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Validity of the transcutaneous PO2-measurement during pharmacologically induced changes of skin perfusion (author's transl)].
    Wendling P; Füssinger R; Schmidt HD; Stosseck K
    Anaesthesist; 1982 Mar; 31(3):135-8. PubMed ID: 7072928
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Transcutaneous PO2 and cardiovascular observations in the sheep fetus following the reduction of uterine blood flow.
    Künzel W; Kastendieck E; Kurz CS; Paulik R
    J Perinat Med; 1980; 8(2):85-92. PubMed ID: 7400920
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The difference between fetal transcutaneous pO2 and arterial pO2 during labour.
    Jensen A; Künzel W
    Gynecol Obstet Invest; 1980; 11(5):249-64. PubMed ID: 7450568
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Transcutaneous measurement of arterial pO2 and local perfusion using a modified Clark electrode].
    Arricivita I
    Rev Enferm; 1982 Sep; 5(50):67-9. PubMed ID: 6925882
    [No Abstract]   [Full Text] [Related]  

  • 9. Skin oxygen permeability in premature infants.
    Versmold HT; Holzmann M; Linderkamp O; Riegel KP
    Pediatrics; 1978 Oct; 62(4):488-91. PubMed ID: 714579
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Interpretation of the tcPO2 curve in adult patients in an intensive care unit.
    Rooth G; Hedstrand U; Ogren C
    Birth Defects Orig Artic Ser; 1979; 15(4):557-71. PubMed ID: 534740
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Examinations on the blood flow dependence of tcPO2 using the model of the "circulatory hyperbola".
    Steinacker JM; Spittelmeister W; Wodick R
    Adv Exp Med Biol; 1987; 220():263-8. PubMed ID: 2960140
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Is transcutaneous oxygen tension independent of variations in blood flow and in arterial blood pressure?
    Eickhoff JH; Jacobsen E
    Biotelem Patient Monit; 1982; 9(3):175-84. PubMed ID: 7159703
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Estimation of blood flow in transcutaneous PO2 measurements.
    Jaszczak P; Poulsen J
    Acta Anaesthesiol Scand; 1983 Apr; 27(2):174-80. PubMed ID: 6837253
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Investigation of arterial claudication with transcutaneous oxygen pressure at exercise: Interests and limits.
    Abraham P; Ramondou P; Hersant J; Sempore WY; Feuilloy M; Henni S
    Trends Cardiovasc Med; 2021 May; 31(4):218-223. PubMed ID: 32234333
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A transcutaneous PO2 electrode for continuous monitoring of fetal state during delivery.
    Stange L; Wussow C
    Int J Gynaecol Obstet; 1976; 14(4):357-63. PubMed ID: 15896
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Monitoring of transcutaneous PO2 in the fetus and mother during normal labor.
    Löfgren O; Jacobson L
    J Perinat Med; 1977; 5(6):252-9. PubMed ID: 611165
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of the transcutaneous oxygen method used at 37 degrees C for measurement of reactive hyperaemia in the skin.
    Ewald U
    Clin Physiol; 1984 Oct; 4(5):413-23. PubMed ID: 6541550
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The influence of cutaneous factors on the transcutaneous pO2 and pCO2 at various body sites.
    Takiwaki H; Nakanishi H; Shono Y; Arase S
    Br J Dermatol; 1991 Sep; 125(3):243-7. PubMed ID: 1911316
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of arterial and venous pressures on transcutaneous oxygen tension.
    Eickhoff JH; Ishihara S; Jacobsen E
    Scand J Clin Lab Invest; 1980; 40(8):755-60. PubMed ID: 7280553
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Age-related changes in microvascular blood flow and transcutaneous oxygen tension under Basal and stimulated conditions.
    Ogrin R; Darzins P; Khalil Z
    J Gerontol A Biol Sci Med Sci; 2005 Feb; 60(2):200-6. PubMed ID: 15814863
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.