  • 21. Water fittings as sources of Legionella pneumophila in a hospital plumbing system.
    Colbourne JS; Pratt DJ; Smith MG; Fisher-Hoch SP; Harper D
    Lancet; 1984 Jan; 1(8370):210-3. PubMed ID: 6141347
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Legionella precautions not to be taken lightly.
    Minett R
    Health Estate; 2006 Nov; 60(10):51-2. PubMed ID: 17137156
    [No Abstract]   [Full Text] [Related]  

  • 23. Abbreviated duration of superheat-and-flush and disinfection of taps for Legionella disinfection: lessons learned from failure.
    Chen YS; Liu YC; Lee SS; Tsai HC; Wann SR; Kao CH; Chang CL; Huang WK; Huang TS; Chao HL; Li CH; Ke CM; Lin YS
    Am J Infect Control; 2005 Dec; 33(10):606-10. PubMed ID: 16330310
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Control of Legionella in hospitals.
    Edelstein PH
    J Hosp Infect; 1986 Sep; 8(2):109-15. PubMed ID: 2876026
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Legionnaires' disease in Staffordshire.
    Lancet; 1986 Jun; 1(8494):1374. PubMed ID: 2872482
    [No Abstract]   [Full Text] [Related]  

  • 26. How to deal with a hospital outbreak of Legionnaires' disease.
    Timbury MC; Donaldson JR; McCartney AC; Winter JH; Fallon RJ
    J Hosp Infect; 1988 Feb; 11 Suppl A():189-200. PubMed ID: 2896705
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Legionnaires': a prescription for prevention.
    Freije M
    Health Facil Manage; 1996 Oct; 9(10):28, 30-2. PubMed ID: 10160382
    [No Abstract]   [Full Text] [Related]  

  • 28. Prevention of Legionnaires' disease in hospitals.
    Sarjomaa M; Urdahl P; Ramsli E; Borchgrevink-Lund CF; Ask E
    Tidsskr Nor Laegeforen; 2011 Aug; 131(16):1554-7. PubMed ID: 21866196
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Legionella in water of medical facilities--a hazard for patients and personnel?].
    Lück PC; Helbig JH; Witzleb W
    Z Gesamte Hyg; 1990 Jul; 36(7):380-2. PubMed ID: 2396455
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Silver/copper ionization is effective for control of Legionella.
    Hayes J
    Clin Infect Dis; 2000 Sep; 31(3):847. PubMed ID: 11185427
    [No Abstract]   [Full Text] [Related]  

  • 31. [Incidence and evaluation of Legionella in hospitals and other large buildings].
    Exner M; Tuschewitzki GJ; Langer B; Wernicke F; Pleischl S
    Schriftenr Ver Wasser Boden Lufthyg; 1993; 91():105-30. PubMed ID: 8235467
    [No Abstract]   [Full Text] [Related]  

  • 32. Heat eradication measures for control of nosocomial Legionnaires' disease. Implementation, education, and cost analysis.
    Best M; Goetz A; Yu VL
    Am J Infect Control; 1984 Feb; 12(1):26-30. PubMed ID: 6422800
    [No Abstract]   [Full Text] [Related]  

  • 33. Proper training key to defeating Legionella.
    Green T
    Health Estate; 2007 Jun; 61(6):34-5. PubMed ID: 17724951
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Legionnaires': a prescription for prevention.
    Freije M
    Health Estate J; 1997 Jun; 51(5):12, 14. PubMed ID: 10169416
    [No Abstract]   [Full Text] [Related]  

  • 35. Screening for nosocomial legionellosis by culture of the water supply and targeting of high-risk patients for specialized laboratory testing.
    Goetz A; Yu VL
    Am J Infect Control; 1991 Apr; 19(2):63-6. PubMed ID: 2053713
    [No Abstract]   [Full Text] [Related]  

  • 36. From the Centers for Disease Control and Prevention. Transmission of nosocomial Legionnaires disease.
    JAMA; 1997 Jun; 277(24):1927-8. PubMed ID: 9200623
    [No Abstract]   [Full Text] [Related]  

  • 37. Fatal nosocomial Legionella pneumophila infection due to exposure to contaminated water from a washbasin in a hematology unit.
    Brûlet A; Nicolle MC; Giard M; Nicolini FE; Michallet M; Jarraud S; Etienne J; Vanhems P
    Infect Control Hosp Epidemiol; 2008 Nov; 29(11):1091-3. PubMed ID: 18937569
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Monitoring of hospital water supplies for Legionella.
    Hay J; Seal DV
    J Hosp Infect; 1994 Jan; 26(1):75-8. PubMed ID: 7910188
    [No Abstract]   [Full Text] [Related]  

  • 39. Legionnaires' disease outbreaks--the engineering implications.
    Harper D
    J R Soc Health; 1987 Feb; 107(1):5-7, 10. PubMed ID: 3102740
    [No Abstract]   [Full Text] [Related]  

  • 40. Efficacy of point-of-entry copper--silver ionisation system in eradicating Legionella pneumophila in a tropical tertiary care hospital: implications for hospitals contaminated with Legionella in both hot and cold water.
    Chen YS; Lin YE; Liu YC; Huang WK; Shih HY; Wann SR; Lee SS; Tsai HC; Li CH; Chao HL; Ke CM; Lu HH; Chang CL
    J Hosp Infect; 2008 Feb; 68(2):152-8. PubMed ID: 18192074
    [TBL] [Abstract][Full Text] [Related]  