These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Development of a high-resolution digital tomosynthesis system and its clinical application. Sone S; Kasuga T; Sakai F; Aoki J; Izuno I; Tanizaki Y; Shigeta H; Shibata K Radiographics; 1991 Sep; 11(5):807-22. PubMed ID: 1947318 [TBL] [Abstract][Full Text] [Related]
4. Correlation between pixel values in a cone-beam computed tomographic scanner and the computed tomographic values in a multidetector row computed tomographic scanner. Chindasombatjaroen J; Kakimoto N; Shimamoto H; Murakami S; Furukawa S J Comput Assist Tomogr; 2011; 35(5):662-5. PubMed ID: 21926866 [TBL] [Abstract][Full Text] [Related]
5. Assessment of Filtered Back Projection, Adaptive Statistical, and Model-Based Iterative Reconstruction for Reduced Dose Abdominal Computed Tomography. Padole A; Singh S; Lira D; Blake MA; Pourjabbar S; Khawaja RD; Choy G; Saini S; Do S; Kalra MK J Comput Assist Tomogr; 2015; 39(4):462-7. PubMed ID: 25734468 [TBL] [Abstract][Full Text] [Related]
6. Application of adaptive non-linear 2D and 3D postprocessing filters for reduced dose abdominal CT. Borgen L; Kalra MK; Laerum F; Hachette IW; Fredriksson CH; Sandborg M; Smedby O Acta Radiol; 2012 Apr; 53(3):335-42. PubMed ID: 22362136 [TBL] [Abstract][Full Text] [Related]
11. The influence of modulation transfer function shape on computed tomographic image quality. Joseph PM; Stockham CD Radiology; 1982 Oct; 145(1):179-85. PubMed ID: 7122876 [TBL] [Abstract][Full Text] [Related]
12. Tin-filter enhanced dual-energy-CT: image quality and accuracy of CT numbers in virtual noncontrast imaging. Kaufmann S; Sauter A; Spira D; Gatidis S; Ketelsen D; Heuschmid M; Claussen CD; Thomas C Acad Radiol; 2013 May; 20(5):596-603. PubMed ID: 23490736 [TBL] [Abstract][Full Text] [Related]
13. Contrast resolution of line-scanned digital radiography. Sommer FG; Brody WR J Comput Assist Tomogr; 1982 Apr; 6(2):373-7. PubMed ID: 7076928 [TBL] [Abstract][Full Text] [Related]
14. A method for increasing the resolution of scanned projection radiography and other digital X-ray systems. Checkley DR; Zhu XP; Hickey DS; Hughes JK; Carter JB; Isherwood I Br J Radiol; 1986 Apr; 59(700):365-71. PubMed ID: 3697614 [TBL] [Abstract][Full Text] [Related]
16. A system for the positioning correlation between computed tomographs and conventional radiographs. Mano I; Kaneko M; Ohshima M Comput Radiol; 1983; 7(1):61-6. PubMed ID: 6831873 [TBL] [Abstract][Full Text] [Related]
17. CT of the chest and abdomen in patients on mechanical pulmonary ventilators: quality of images made at 0.6 vs 1.0 sec. Posniak HV; Olson MC; Demos TC; Pierce KL; Kalbhen CL AJR Am J Roentgenol; 1994 Nov; 163(5):1073-7. PubMed ID: 7976877 [TBL] [Abstract][Full Text] [Related]
18. Measurements from digital scanned projection radiographs: couch detail and detector artefact removal by simple image enhancement. Moore CJ Br J Radiol; 1985 Aug; 58(692):756-9. PubMed ID: 3842279 [No Abstract] [Full Text] [Related]
19. [Material-selective imaging and density measurement using the dual-energy method. I. Principles and methodology]. Kalender W; Bautz W; Felsenberg D; Süss C; Klotz E Digitale Bilddiagn; 1987 Jun; 7(2):66-72. PubMed ID: 3621809 [TBL] [Abstract][Full Text] [Related]
20. Edge enhancement of computed tomograms by digital unsharp masking. Winter J Radiology; 1980 Apr; 135(1):234-5. PubMed ID: 7360972 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]