BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

206 related articles for article (PubMed ID: 6863347)

  • 1. A new approach to the design of internal fixation plates.
    Woo SL; Simon BR; Akeson WH; Gomez MA; Seguchi Y
    J Biomed Mater Res; 1983 May; 17(3):427-39. PubMed ID: 6863347
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Less rigid internal fixation plates: historical perspectives and new concepts.
    Woo SL; Lothringer KS; Akeson WH; Coutts RD; Woo YK; Simon BR; Gomez MA
    J Orthop Res; 1984; 1(4):431-49. PubMed ID: 6491792
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Principles of less rigid internal fixation with plates.
    Akeson WH; Coutts RD; Woo SL
    Can J Surg; 1980 May; 23(3):235-9. PubMed ID: 7378954
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The biomechanics of human femurs in axial and torsional loading: comparison of finite element analysis, human cadaveric femurs, and synthetic femurs.
    Papini M; Zdero R; Schemitsch EH; Zalzal P
    J Biomech Eng; 2007 Feb; 129(1):12-9. PubMed ID: 17227093
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Assessment of carbon fibre composite fracture fixation plate using finite element analysis.
    Saidpour SH
    Ann Biomed Eng; 2006 Jul; 34(7):1157-63. PubMed ID: 16732432
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The mechanical and morphological properties of bone beneath internal fixation plates of differing rigidity.
    Claes L
    J Orthop Res; 1989; 7(2):170-7. PubMed ID: 2918416
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A short plate compression screw with diagonal bolts--a biomechanical evaluation performed experimentally and by numerical computation.
    Peleg E; Mosheiff R; Liebergall M; Mattan Y
    Clin Biomech (Bristol, Avon); 2006 Nov; 21(9):963-8. PubMed ID: 16893595
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biomechanical optimization of bone plates used in rigid fixation of mandibular fractures.
    Lovald ST; Wagner JD; Baack B
    J Oral Maxillofac Surg; 2009 May; 67(5):973-85. PubMed ID: 19375006
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reduction of stress shielding beneath a bone plate by use of a polymeric underplate. An experimental study in dogs.
    Jasmine MS; Dahners LE; Gilbert JA
    Clin Orthop Relat Res; 1989 Sep; (246):293-9. PubMed ID: 2766617
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of stainless steel and composite plates in the healing of diaphyseal osteotomies of the dog radius: report on a short term study.
    Coutts RE; Akeson WH; Woo S; Matthews JV; Gonsalves M; Amiel D
    Orthop Clin North Am; 1976 Jan; 7(1):223-9. PubMed ID: 1256790
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanical optimization of bone plates used in rigid fixation of mandibular symphysis fractures.
    Lovald S; Baack B; Gaball C; Olson G; Hoard A
    J Oral Maxillofac Surg; 2010 Aug; 68(8):1833-41. PubMed ID: 20537782
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effects of the bone-plate material and the presence of a gap between the fractured bone and plate on the predicted stresses at the fractured bone.
    Fouad H
    Med Eng Phys; 2010 Sep; 32(7):783-9. PubMed ID: 20627657
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Theoretical analysis and numerical simulation of effect of steel plate positions on steel plate rigidity in internal fixation of bone surgery].
    Chen B; Gu Y; Lü D; Lü X
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2003 Sep; 20(3):425-9. PubMed ID: 14565005
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Assessment of function-graded materials as fracture fixation bone-plates under combined loading conditions using finite element modelling.
    Fouad H
    Med Eng Phys; 2011 May; 33(4):456-63. PubMed ID: 21146439
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical analysis of a new carbon fiber/flax/epoxy bone fracture plate shows less stress shielding compared to a standard clinical metal plate.
    Bagheri ZS; Tavakkoli Avval P; Bougherara H; Aziz MS; Schemitsch EH; Zdero R
    J Biomech Eng; 2014 Sep; 136(9):091002. PubMed ID: 24828985
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Biomechanical comparative study of three types of osteosynthesis in the treatment of supra and intercondylar fractures of the humerus in adults].
    Fornasiéri C; Staub C; Tourné Y; Rumelhart C; Saragaglia D
    Rev Chir Orthop Reparatrice Appar Mot; 1997; 83(3):237-42. PubMed ID: 9255359
    [TBL] [Abstract][Full Text] [Related]  

  • 17. On optimization of a composite bone plate using the selective stress shielding approach.
    Samiezadeh S; Tavakkoli Avval P; Fawaz Z; Bougherara H
    J Mech Behav Biomed Mater; 2015 Feb; 42():138-53. PubMed ID: 25482217
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Computerized analysis of resorbable polymer plates and screws for the rigid fixation of mandibular angle fractures.
    Cox T; Kohn MW; Impelluso T
    J Oral Maxillofac Surg; 2003 Apr; 61(4):481-7; discussion 487-8. PubMed ID: 12684967
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of fracture gap on stability of compression plate fixation: a finite element study.
    Oh JK; Sahu D; Ahn YH; Lee SJ; Tsutsumi S; Hwang JH; Jung DY; Perren SM; Oh CW
    J Orthop Res; 2010 Apr; 28(4):462-7. PubMed ID: 19862799
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Experimental studies on "less rigid" polyacetal plates for fracture fixation (author's transl)].
    Kusunose K
    Nihon Seikeigeka Gakkai Zasshi; 1982 May; 56(5):399-414. PubMed ID: 7108319
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.