BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 6864496)

  • 1. Comparison of high-performance liquid chromatography and radioimmunoassay in the determination of content uniformity of digoxin tablets.
    Beasley MW; Skierkowski P; Cleary RW; Jones AB; Kibbe AH
    J Pharm Sci; 1983 May; 72(5):505-8. PubMed ID: 6864496
    [TBL] [Abstract][Full Text] [Related]  

  • 2. High-performance liquid chromatographic analysis of digoxin formulations.
    Desta B; McErlane KM
    J Pharm Sci; 1982 Jul; 71(7):777-80. PubMed ID: 7120061
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Micro high-performance liquid chromatographic determination of cardiac glycosides in beta-methyldigoxin and digoxin tablets.
    Fujii Y; Ikeda Y; Yamazaki M
    J Chromatogr; 1988 Aug; 448(1):157-64. PubMed ID: 3225296
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Factors of importance for valid digitalis assays particularly for the determination of digoxin in plasma and urine.
    Molin L
    Acta Pharmacol Toxicol (Copenh); 1986; 59 Suppl 4():1-62. PubMed ID: 3739734
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Stability-indicating assay, dissolution, and content uniformity of sodium levothyroxine in tablets.
    Richheimer SL; Amer TM
    J Pharm Sci; 1983 Nov; 72(11):1349-51. PubMed ID: 6644603
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Tablet splitting: is it worthwhile? Analysis of drug content and weight uniformity for half tablets of 16 commonly used medications in the outpatient setting.
    Helmy SA
    J Manag Care Spec Pharm; 2015 Jan; 21(1):76-86. PubMed ID: 25562775
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of analysis of digoxin in cardiac patients by HPLC and RIA.
    Kwong E; Embree L; McErlane KM
    Res Commun Chem Pathol Pharmacol; 1990 Apr; 68(1):121-4. PubMed ID: 2345802
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Isolation by high-performance liquid chromatography and quantitation by radioimmunoassay of therapeutic concentrations of digoxin and metabolites.
    Nelson HA; Lucas SV; Gibson TP
    J Chromatogr; 1979 Jun; 163(2):169-77. PubMed ID: 541368
    [TBL] [Abstract][Full Text] [Related]  

  • 9. HPLC method with UV detection for evaluation of digoxin tablet dissolution in acidic medium after solid-phase extraction.
    Jedlicka A; Grafnetterová T; Miller V
    J Pharm Biomed Anal; 2003 Sep; 33(1):109-15. PubMed ID: 12946537
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Analysis of drug content and weight uniformity for half-tablets of 6 commonly split medications.
    Hill SW; Varker AS; Karlage K; Myrdal PB
    J Manag Care Pharm; 2009 Apr; 15(3):253-61. PubMed ID: 19326956
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Determination of sodium levothyroxine in bulk, tablet, and injection formulations by high-performance liquid chromatography.
    Brower JF; Toler DY; Reepmeyer JC
    J Pharm Sci; 1984 Sep; 73(9):1315-7. PubMed ID: 6491963
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Content uniformity for digoxin tablet].
    Tokunaga H; Kimura T; Kawamura J
    Eisei Shikenjo Hokoku; 1974; 49(92):66-70. PubMed ID: 4477502
    [No Abstract]   [Full Text] [Related]  

  • 13. Comparison of a commercial urinary neopterin radioimmunoassay with high performance liquid chromatography.
    Hammerer-Lercher A; Moser C; Leichtfried V; Schobersberger W; Griesmacher A; Fuchs D
    Clin Chem Lab Med; 2012 Jan; 50(6):1075-8. PubMed ID: 22706249
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The question of cumulation of digoxin metabolites in renal failure.
    Gibson TP; Nelson HA
    Clin Pharmacol Ther; 1980 Feb; 27(2):219-23. PubMed ID: 7353343
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Detection of digoxin, digitoxin, their cardioactive metabolites and derivatives by high-performance liquid chromatography and high-performance liquid chromatography-radioimmunoassay.
    Plum J; Daldrup T
    J Chromatogr; 1986 Apr; 377():221-31. PubMed ID: 3711211
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of high performance liquid chromatography, radio immunoassay and electrochemiluminescence immunoassay for quantification of serum 25 hydroxy vitamin D.
    Jafri L; Khan AH; Siddiqui AA; Mushtaq S; Iqbal R; Ghani F; Siddiqui I
    Clin Biochem; 2011 Jul; 44(10-11):864-8. PubMed ID: 21570387
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparative in vivo evaluation of a radioimmunoassay and a chromatographic assay for the measurement of digoxin in biological fluids.
    Hinderling PH; Magnusson JO; Molin L
    J Pharm Sci; 1986 May; 75(5):517-21. PubMed ID: 3735093
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Development of radioimmunoassay for measurement of serum digoxin in digitalized patients using novel anti-digoxin antiserum.
    Ikeda Y; Araki T; Takimoto H; Fujii Y
    Biol Pharm Bull; 2002 Apr; 25(4):422-5. PubMed ID: 11995917
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of cyclosporine determinations in whole blood by three different methods. HPLC, 125I RIA and 3H RIA.
    Huang WY; Lipsey AI; Cheng MH
    Am J Clin Pathol; 1987 Apr; 87(4):528-32. PubMed ID: 3826016
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Quantitation of digoxigenin in serum following oral administration of digoxin in humans.
    Loo JC; McGilveray IJ; Jordan N
    Res Commun Chem Pathol Pharmacol; 1977 Jul; 17(3):497-506. PubMed ID: 897341
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.