These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

111 related articles for article (PubMed ID: 6869061)

  • 21. A Modified Ogata-Goldsand Technique for Simplified Intraoperative Measurement of Femoral Version.
    Morris WZ; Henry H; Liu RW; Streit JJ; Grant RE; Cooperman DR
    J Pediatr Orthop; 2015 Sep; 35(6):593-9. PubMed ID: 25379819
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Measuring anteversion and femoral neck-shaft angle in cerebral palsy.
    Miller F; Liang Y; Merlo M; Harcke HT
    Dev Med Child Neurol; 1997 Feb; 39(2):113-8. PubMed ID: 9062426
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [The measurement of the femoral torsion angle in children by NMR tomography compared to CT and ultrasound].
    Tomczak R; Günther K; Pfeifer T; Häberle HJ; Rieber A; Danz B; Rilinger N; Friedrich JM; Brambs HJ
    Rofo; 1995 Mar; 162(3):224-8. PubMed ID: 7718777
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Computed tomographic determination of the anteversion angle. Premises and possibilities].
    Jend HH
    Rofo; 1986 Apr; 144(4):447-52. PubMed ID: 3008259
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Anteversion of the acetabulum in patients with idiopathic increased anteversion of the femoral neck.
    Reikerås O; Bjerkreim I; Kolbenstvedt A
    Acta Orthop Scand; 1982 Dec; 53(6):847-52. PubMed ID: 7180394
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Anteversion of the femoral neck in congenital dislocation of the hip.
    Koshimune G
    Acta Med Okayama; 1985 Jun; 39(3):221-30. PubMed ID: 4024993
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Imaging observation of the femoral neck anteversion in patients with developmental dysplasia of the hip].
    Xiao K; Zhang H; Luo D; Zang J; Cheng H
    Zhonghua Wai Ke Za Zhi; 2015 May; 53(5):353-6. PubMed ID: 26082250
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Measurement of femoral anteversion by magnetic resonance imaging--evaluation of a new technique in children and adolescents.
    Guenther KP; Tomczak R; Kessler S; Pfeiffer T; Puhl W
    Eur J Radiol; 1995 Nov; 21(1):47-52. PubMed ID: 8654459
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Femoral Morphology in the Dysplastic Hip: Three-dimensional Characterizations With CT.
    Wells J; Nepple JJ; Crook K; Ross JR; Bedi A; Schoenecker P; Clohisy JC
    Clin Orthop Relat Res; 2017 Apr; 475(4):1045-1054. PubMed ID: 27752989
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Accuracy of CT for measuring femoral neck anteversion in children with developmental dislocation of the hip verified using 3D printing technology.
    Cai Z; Piao C; Zhang T; Li L; Xiang L
    J Orthop Surg Res; 2021 Apr; 16(1):256. PubMed ID: 33853657
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Study of cotyloid anteversion by coxometric measurement].
    Fabeck L; Farrokh D; Tolley M; Tollet P; Descamps PY; Quintin J; Delincé P
    J Radiol; 1998 Aug; 79(8):743-50. PubMed ID: 9757304
    [TBL] [Abstract][Full Text] [Related]  

  • 32. MPR realignment increases accuracy when measuring femoral neck anteversion angle.
    Olesen TH; Torfing T; Overgaard S
    Skeletal Radiol; 2013 Aug; 42(8):1119-25. PubMed ID: 23689688
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Measurement of femoral neck anteversion in 3D. Part 2: 3D modelling method.
    Kim JS; Park TS; Park SB; Kim JS; Kim IY; Kim SI
    Med Biol Eng Comput; 2000 Nov; 38(6):610-6. PubMed ID: 11217877
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Femoral anteversion.
    Murphy SB; Simon SR; Kijewski PK; Wilkinson RH; Griscom NT
    J Bone Joint Surg Am; 1987 Oct; 69(8):1169-76. PubMed ID: 3667647
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Measurement of the femoral neck anteversion angle in the dog using computed tomography.
    Ginja MM; Gonzalo-Orden JM; Jesus SS; Silvestre AM; Llorens-Pena MP; Ferreira AJ
    Vet J; 2007 Sep; 174(2):378-83. PubMed ID: 17015023
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Rippstein and Müller roentgenologic determination of the actual femoral neck-shaft and antetorsion angle. 1: Correction of the conversion table and study of the effects of positioning errors].
    Grunert S; Brückl R; Rosemeyer B
    Radiologe; 1986 Jun; 26(6):293-304. PubMed ID: 3749501
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Measurement of femoral neck anteversion and inclination. A radiographic study in children.
    Henriksson L
    Acta Orthop Scand Suppl; 1980; 186():1-59. PubMed ID: 6938105
    [No Abstract]   [Full Text] [Related]  

  • 38. [Use of ultrasonography for measurement of femur anteversion and tibial torsion in children].
    Paściak M; Stoll TM; Hefti F
    Chir Narzadow Ruchu Ortop Pol; 1994; 59(4):279-83. PubMed ID: 7656675
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Do physical examination and CT-scan measures of femoral neck anteversion and tibial torsion relate to each other?
    Sangeux M; Mahy J; Graham HK
    Gait Posture; 2014 Jan; 39(1):12-6. PubMed ID: 23787150
    [TBL] [Abstract][Full Text] [Related]  

  • 40. MR imaging measurement of the femoral antetorsional angle as a new technique: comparison with CT in children and adults.
    Tomczak RJ; Guenther KP; Rieber A; Mergo P; Ros PR; Brambs HJ
    AJR Am J Roentgenol; 1997 Mar; 168(3):791-4. PubMed ID: 9057536
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.