These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

111 related articles for article (PubMed ID: 6869875)

  • 1. A modification of Allen's test to detect aberrant ulnar collateral circulation.
    Gandhi SK; Reynolds AC
    Anesthesiology; 1983 Aug; 59(2):147-8. PubMed ID: 6869875
    [No Abstract]   [Full Text] [Related]  

  • 2. Evaluation of the palmar circulation by pulse oximetry.
    Cheng EY; Lauer KK; Stommel KA; Guenther NR
    J Clin Monit; 1989 Jan; 5(1):1-3. PubMed ID: 2926462
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of digital blood pressure, plethysmography, and the modified Allen's test as means of evaluating the collateral circulation to the hand.
    Fuhrman TM; Reilley TE; Pippin WD
    Anaesthesia; 1992 Nov; 47(11):959-61. PubMed ID: 1466436
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of collateral circulation of the hand.
    Fuhrman TM; Pippin WD; Talmage LA; Reilley TE
    J Clin Monit; 1992 Jan; 8(1):28-32. PubMed ID: 1538249
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Three-digit Allen's test.
    Asif M; Sarkar PK
    Ann Thorac Surg; 2007 Aug; 84(2):686-7. PubMed ID: 17643672
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reliability of Allen's test in selection of patients for radial artery harvest.
    Jarvis MA; Jarvis CL; Jones PR; Spyt TJ
    Ann Thorac Surg; 2000 Oct; 70(4):1362-5. PubMed ID: 11081899
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Assessment of digital blood flow and palmar collateral circulation. Allen's test vs. photoplethysmography.
    Stead SW; Stirt JA
    Int J Clin Monit Comput; 1985; 2(1):29-34. PubMed ID: 3835222
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of a postocclusive reactive circulatory hyperaemia (PORCH) test for the assessment of ulnar collateral circulation.
    Vaghadia H; Schechter MT; Sheps SB; Jenkins LC
    Can J Anaesth; 1988 Nov; 35(6):591-8. PubMed ID: 3060281
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Can the modified Allen's test always detect sufficient collateral flow in the hand? A computational study.
    Alastruey J; Parker KH; Peiró J; Sherwin SJ
    Comput Methods Biomech Biomed Engin; 2006 Dec; 9(6):353-61. PubMed ID: 17145669
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Doppler velocimetric evaluation of the reliability of Allen's test for radial artery catheterization].
    Marcillon M; Maestracci P; Guillot F; Dulbecco P; Filippi C; Valici A
    Ann Fr Anesth Reanim; 1982; 1(4):403-6. PubMed ID: 7171137
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Noninvasive evaluation of hand circulation before radial artery harvest for coronary artery bypass grafting.
    Starnes SL; Wolk SW; Lampman RM; Shanley CJ; Prager RL; Kong BK; Fowler JJ; Page JM; Babcock SL; Lange LA; Erlandson EE; Whitehouse WM
    J Thorac Cardiovasc Surg; 1999 Feb; 117(2):261-6. PubMed ID: 9918966
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Detection of collateral circulation of the palmar arcade: comparison of results with use of the Doplette-10, the modified Allen's test and finger photo-plethysmography.
    Swanson JH; Weeks DB
    AANA J; 1978 Oct; 46(5):512-6. PubMed ID: 716828
    [No Abstract]   [Full Text] [Related]  

  • 13. Allen's test and systolic arterial pressure in the thumb.
    Husum B; Berthelsen P
    Br J Anaesth; 1981 Jun; 53(6):635-7. PubMed ID: 7248127
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Evaluation of palmar collateral circulation with the Oxygenmet oxygen saturation measurement device].
    Bechstein WO; Schaps DK; Kirchner E
    Anasth Intensivther Notfallmed; 1984 Dec; 19(6):312-3. PubMed ID: 6524642
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Modified Allen's Test in radiocephalic arterio-venous fistula creation: how relevant?
    Thomas MO; Awobusuyi JO
    Niger Postgrad Med J; 2004 Jun; 11(2):88-90. PubMed ID: 15300267
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The Allen's test: analysis of four methods.
    Levinsohn DG; Gordon L; Sessler DI
    J Hand Surg Am; 1991 Mar; 16(2):279-82. PubMed ID: 2022838
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Palmar arch anatomy: Ajmer Working Group classification.
    Gokhroo R; Bisht D; Gupta S; Kishor K; Ranwa B
    Vascular; 2016 Feb; 24(1):31-6. PubMed ID: 25757609
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A practical way of performing Allen's test to assess palmar collateral circulation.
    Castella X
    Anesth Analg; 1993 Nov; 77(5):1085-6. PubMed ID: 8214723
    [No Abstract]   [Full Text] [Related]  

  • 19. Transradial Approach for Cardiac Catheterization in Patients With Negative Allen's Test.
    Maniotis C; Koutouzis M; Andreou C; Lazaris E; Tsiafoutis I; Zografos T; Chantziara K; Nikolidakis S; Kyriakides ZS
    J Invasive Cardiol; 2015 Sep; 27(9):416-20. PubMed ID: 26121707
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The radial hyperaemic response: a new and objective assessment of ulnar collateral supply to the hand.
    Roberts N; Ghosh S; Boehm M; Galiñanes M
    Eur J Cardiothorac Surg; 2002 Mar; 21(3):549-52. PubMed ID: 11888782
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.