These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 6871051)

  • 1. Inaccuracy of oesophageal pressure for pleural pressure estimation in supine anaesthetized subjects.
    Drummond GB; Wright AD
    Br J Anaesth; 1983 Jul; 55(7):585-93. PubMed ID: 6871051
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measurement of pleural pressure with esophageal balloon in anesthetized humans.
    Higgs BD; Behrakis PK; Bevan DR; Milic-Emili J
    Anesthesiology; 1983 Oct; 59(4):340-3. PubMed ID: 6614543
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Detailed measurements of oesophageal pressure during mechanical ventilation with an advanced high-resolution manometry catheter.
    Persson P; Ahlstrand R; Gudmundsson M; de Leon A; Lundin S
    Crit Care; 2019 Jun; 23(1):217. PubMed ID: 31196203
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A comparison of oesophageal and central venous pressures in the measurement of transpulmonary pressure change.
    Walling PT; Savege TM
    Br J Anaesth; 1976 May; 48(5):475-9. PubMed ID: 1276021
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Measurement of pleural pressure with oesophageal catheter-tip micromanometer in anaesthetized humans.
    Chartrand DA; Jodoin C; Couture J
    Can J Anaesth; 1991 May; 38(4 Pt 1):518-21. PubMed ID: 2065421
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Lung elastance and transpulmonary pressure can be determined without using oesophageal pressure measurements.
    Stenqvist O; Grivans C; Andersson B; Lundin S
    Acta Anaesthesiol Scand; 2012 Jul; 56(6):738-47. PubMed ID: 22524531
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Oesophageal pressure measurement in rabbits and human infants using an air-filled balloon system.
    Deen L; Porcelijn T
    Br J Anaesth; 1976 Jun; 48(6):521-26. PubMed ID: 782493
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of central venous, oesophageal and mouth occlusion pressure with water-filled catheters for estimating pleural pressure changes in healthy adults.
    Flemale A; Gillard C; Dierckx JP
    Eur Respir J; 1988 Jan; 1(1):51-7. PubMed ID: 3366236
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Pressure-volume and airway closure relationships in each lung in anaesthetized man.
    Hedenstierna G; Bindslev L; Santesson J
    Clin Physiol; 1981 Oct; 1(5):479-93. PubMed ID: 7199995
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Measurement of pleural pressure swings with a fluid-filled esophageal catheter vs pulmonary artery occlusion pressure.
    Verscheure S; Massion PB; Gottfried S; Goldberg P; Samy L; Damas P; Magder S
    J Crit Care; 2017 Feb; 37():65-71. PubMed ID: 27636673
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The concordance of respiratory fluctuations in oesophageal and central venous pressures.
    Hedstrand U; Jakobson S; Nylund U; Sterner H
    Ups J Med Sci; 1976; 81(1):49-53. PubMed ID: 1273999
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Oesophageal pressure measurements in ventilated preterm babies.
    Greenough A; Morley CJ
    Arch Dis Child; 1982 Nov; 57(11):851-5. PubMed ID: 7149758
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Measurement of pleural pressure at low and high frequencies in normal rabbits.
    Chartrand DA; Ye TH; Maarek JM; Chang HK
    J Appl Physiol (1985); 1987 Sep; 63(3):1142-6. PubMed ID: 3654460
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The application of esophageal pressure measurement in patients with respiratory failure.
    Akoumianaki E; Maggiore SM; Valenza F; Bellani G; Jubran A; Loring SH; Pelosi P; Talmor D; Grasso S; Chiumello D; Guérin C; Patroniti N; Ranieri VM; Gattinoni L; Nava S; Terragni PP; Pesenti A; Tobin M; Mancebo J; Brochard L;
    Am J Respir Crit Care Med; 2014 Mar; 189(5):520-31. PubMed ID: 24467647
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Monitoring of oesophageal pressure.
    Keller SP; Fessler HE
    Curr Opin Crit Care; 2014 Jun; 20(3):340-6. PubMed ID: 24751808
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Influence of lung and chest wall compliances on transmission of airway pressure to the pleural space in critically ill patients.
    Jardin F; Genevray B; Brun-Ney D; Bourdarias JP
    Chest; 1985 Nov; 88(5):653-8. PubMed ID: 3902386
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of airway occlusion on respiratory timing during anaesthesia with enflurane or halothane.
    Drummond GB
    Br J Anaesth; 1984 Mar; 56(3):215-21. PubMed ID: 6704270
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A simple method for assessing the validity of the esophageal balloon technique.
    Baydur A; Behrakis PK; Zin WA; Jaeger M; Milic-Emili J
    Am Rev Respir Dis; 1982 Nov; 126(5):788-91. PubMed ID: 7149443
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Airway compliance during artificial ventilation.
    Hedenstierna G; Lundberg S
    Br J Anaesth; 1975 Dec; 47(12):1277-81. PubMed ID: 1218167
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Validation of esophageal balloon technique at different lung volumes and postures.
    Baydur A; Cha EJ; Sassoon CS
    J Appl Physiol (1985); 1987 Jan; 62(1):315-21. PubMed ID: 3558190
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.