147 related articles for article (PubMed ID: 6872209)
1. Interference by hemolysis with various methods for total calcium and its correction by trichloroacetic acid precipitation.
Chan KM; Arriaga C; Landt M; Smith CH; Ng RH
Clin Chem; 1983 Aug; 29(8):1497-500. PubMed ID: 6872209
[TBL] [Abstract][Full Text] [Related]
2. Hemoglobin interference with Du Pont Automatic Clinical Analyzer procedure for calcium.
Porter WH; Carroll JR; Roberts RE
Clin Chem; 1977 Nov; 23(11):2145-7. PubMed ID: 912882
[TBL] [Abstract][Full Text] [Related]
3. Evaluation of the revised serum calcium procedure used with the Du Pont automatic clinical analyzer.
Sage GW; LeFever D; Henry JB
Clin Chem; 1975 Jun; 21(7):850-2. PubMed ID: 1132136
[TBL] [Abstract][Full Text] [Related]
4. Evaluation of the Corning 940 Calcium Titator for use with serum and urine.
Weissman EB; Pragay DA; Bishop C
Clin Chem; 1975 Feb; 21(2):264-7. PubMed ID: 1112034
[TBL] [Abstract][Full Text] [Related]
5. Evaluation of the ASTRA o-cresolphthalein complexone calcium method.
Hartmann AE; Lewis LR
Am J Clin Pathol; 1984 Aug; 82(2):182-7. PubMed ID: 6465080
[TBL] [Abstract][Full Text] [Related]
6. Modified Dupont aca calcium method for hemolyzed specimens.
Haas RG; Mushel S
Am J Clin Pathol; 1982 Feb; 77(2):216-9. PubMed ID: 6801968
[TBL] [Abstract][Full Text] [Related]
7. Effects of dextran on five biuret-based procedures for total protein in serum.
Barnes DB; Pierce GF; Lichti D; Landt M; Koenig J; Chan KM
Clin Chem; 1985 Dec; 31(12):2018-9. PubMed ID: 2415271
[TBL] [Abstract][Full Text] [Related]
8. Lithium determinations evaluated in eight analyzers.
Sampson M; Ruddel M; Elin RJ
Clin Chem; 1994 Jun; 40(6):869-72. PubMed ID: 8087980
[TBL] [Abstract][Full Text] [Related]
9. Study of forensic and clinical source hemoglobin interference with the duPont aca ethanol method.
Gadsden RH
Ann Clin Lab Sci; 1986; 16(5):399-406. PubMed ID: 3777857
[TBL] [Abstract][Full Text] [Related]
10. Interference by haemoglobin with the cresolphthalein complexone method for serum calcium measurement.
Corns CM
Ann Clin Biochem; 1990 Mar; 27 ( Pt 2)():152-5. PubMed ID: 2327710
[TBL] [Abstract][Full Text] [Related]
11. Influence of mechanical hemolysis of blood on two D-dimer immunoassays.
Lippi G; Avanzini P; Zobbi V; Ippolito L
Blood Coagul Fibrinolysis; 2012 Jul; 23(5):461-3. PubMed ID: 22576291
[TBL] [Abstract][Full Text] [Related]
12. Strong interference of hemoglobin concentration on CSF total protein measurement using the trichloroacetic acid precipitation method.
Boer K; Isenmann S; Deufel T
Clin Chem Lab Med; 2007; 45(1):112-3. PubMed ID: 17243927
[TBL] [Abstract][Full Text] [Related]
13. Microdetermination of serum calcium by parallel fast analyzer.
Dito WR
Am J Clin Pathol; 1976 Jun; 65(6):1016-21. PubMed ID: 937244
[TBL] [Abstract][Full Text] [Related]
14. Total calcium and magnesium determined in serum with an automated stopped-flow analyzer.
Koupparis MA; Diamandis EP; Malmstadt HV
Clin Chem; 1982 Oct; 28(10):2149-52. PubMed ID: 7127745
[TBL] [Abstract][Full Text] [Related]
15. Hemoglobin interference from in vivo hemolysis.
Blank DW; Kroll MH; Ruddel ME; Elin RJ
Clin Chem; 1985 Sep; 31(9):1566-9. PubMed ID: 4028407
[TBL] [Abstract][Full Text] [Related]
16. Evaluation of an automatic calcium titrator.
Alexander RL
Clin Chem; 1971 Dec; 17(12):1171-5. PubMed ID: 5118156
[No Abstract] [Full Text] [Related]
17. 2-Amino-2-methyl-1-propanol as the alkalizing agent in an improved continuous-flow cresolphthalein complexone procedure for calcium in serum.
Moorehead WR; Biggs HG
Clin Chem; 1974 Nov; 20(11):1458-60. PubMed ID: 4421368
[No Abstract] [Full Text] [Related]
18. Two automated fully enzymatic assays for lipase activity in serum compared: positive interference from post-heparin lipase activity.
Demanet C; Goedhuys W; Haentjens M; Huyghens L; Blaton V; Gorus F
Clin Chem; 1992 Feb; 38(2):288-92. PubMed ID: 1541012
[TBL] [Abstract][Full Text] [Related]
19. Falsely low value for total protein in urine as measured in the Du Pont aca discrete clinical analyzer.
Lacher DA; DeBeukelaer M
Clin Chem; 1986 Jan; 32(1 Pt 1):203. PubMed ID: 3940712
[No Abstract] [Full Text] [Related]
20. Centrifugal analysis with automated sequential reagent addition: measurement of serum calcium.
Liedtke RJ; Kroon G; Batjer JD
Clin Chem; 1981 Dec; 27(12):2025-8. PubMed ID: 6796291
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]