These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

105 related articles for article (PubMed ID: 6872229)

  • 1. Choice of a satisfactory evacuated blood-collection tube for magnesium and zinc assays.
    Speich M; Gelot S
    Clin Chem; 1983 Aug; 29(8):1560-1. PubMed ID: 6872229
    [No Abstract]   [Full Text] [Related]  

  • 2. Interference of zinc heparin anticoagulant in determination of plasma magnesium.
    Wilhite TR; Smith CH; Landt M
    Clin Chem; 1994 May; 40(5):848-9. PubMed ID: 8174268
    [No Abstract]   [Full Text] [Related]  

  • 3. Trace metal contamination of evacuated blood collection tubes.
    Nackowski SB; Putnam RD; Robbins DA; Varner MO; White LD; Nelson KW
    Am Ind Hyg Assoc J; 1977 Oct; 38(10):503-8. PubMed ID: 920600
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Zinc in plasma and serum: influence of contamination due to the collection tubes.
    Keyzer JJ; Oosting E; Wolthers BG; Muskiet FA; Hindriks FR; Van der Slik W
    Pharm Weekbl Sci; 1983 Oct; 5(5):248-51. PubMed ID: 6646993
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Trace element contamination in blood-collecting devices.
    Lecomte R; Paradis P; Monaro S; Barrette M; Lamoureux G; Ménard HA
    Int J Nucl Med Biol; 1979; 6(4):207-11. PubMed ID: 528146
    [No Abstract]   [Full Text] [Related]  

  • 6. Evacuated tubes and possible false-positive PCR results with blood samples.
    Hauman JH; van Helden PD; Hauman CH
    S Afr Med J; 1995 Feb; 85(2):119. PubMed ID: 7597528
    [No Abstract]   [Full Text] [Related]  

  • 7. [Copper, zinc and aluminum contamination of blood specimens used for determination of these metals].
    Clavel JP; Lavirotte P; Galli A
    Pathol Biol (Paris); 1983 Dec; 31(10):851-4. PubMed ID: 6669401
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Magnesium contamination from Terumo blood collection tubes.
    Dimeski G; Carter A
    Clin Chem; 2006 Aug; 52(8):1612-4. PubMed ID: 16873304
    [No Abstract]   [Full Text] [Related]  

  • 9. Technique of handling neonatal blood samples for zinc analysis.
    Michie DD; Bell NH; Wirth FH
    Am J Med Technol; 1976 Nov; 42(11):424-7. PubMed ID: 984078
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Prothrombin time ratio is reduced by magnesium contamination in evacuated blood collection tubes.
    van den Besselaar AM; van Dam W; Sturk A; Bertina RM
    Thromb Haemost; 2001 Apr; 85(4):647-50. PubMed ID: 11341499
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A comparison of hard and soft glass blood-drawing tubes.
    Laessig RH; Hassemer DJ; Hoffman GL; Westgard JO; Carey RN; Feldbruegge DH
    Am J Clin Pathol; 1979 Dec; 72(6):952-5. PubMed ID: 517461
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of magnesium contamination in evacuated blood collection tubes on the prothrombin time test and ISI calibration using recombinant human thromboplastin and different types of coagulometer.
    van den Besselaar AM; Rutten WP; Witteveen E
    Thromb Res; 2005; 115(3):239-44. PubMed ID: 15617747
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Impact of evacuated collection tube fill volume and mixing on routine coagulation testing using 2.5-ml (pediatric) tubes.
    Chuang J; Sadler MA; Witt DM
    Chest; 2004 Oct; 126(4):1262-6. PubMed ID: 15486391
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Trace metal determinations in blood obtained in evacuated collection tubes.
    Williams DM
    Clin Chim Acta; 1979 Nov; 99(1):23-9. PubMed ID: 498541
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Blood-collection device for trace and ultra-trace metal specimens evaluated.
    Moyer TP; Mussmann GV; Nixon DE
    Clin Chem; 1991 May; 37(5):709-14. PubMed ID: 2032325
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Qualification process for evacuated blood collection tubes: application to the choice of serum collection tubes].
    Guerber F
    Ann Biol Clin (Paris); 2000; 58(6):754-6. PubMed ID: 11098178
    [No Abstract]   [Full Text] [Related]  

  • 17. Pseudomonas maltophilia pseudosepticemia.
    Semel JD; Trenholme GM; Harris AA; Jupa JE; Levin S
    Am J Med; 1978 Mar; 64(3):403-6. PubMed ID: 637055
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A "wash-out pipet system" for sampling red blood cells.
    Stoler RG
    Clin Chem; 1972 Mar; 18(3):301-3. PubMed ID: 5020830
    [No Abstract]   [Full Text] [Related]  

  • 19. Comparison of blood specimens from plain and gel vacuum blood collection tubes.
    Wiwanitkit V
    J Med Assoc Thai; 2001 May; 84(5):723-6. PubMed ID: 11560224
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Behavior of zinc and magnesium in stored blood].
    Lukasiak S; Kosk-Kosicka D; Daszyński J
    Acta Haematol Pol; 1975; 6(3):217-25. PubMed ID: 1163186
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.