These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 6876269)

  • 1. The estimation of bladder volume by sonocystography.
    Hakenberg OW; Ryall RL; Langlois SL; Marshall VR
    J Urol; 1983 Aug; 130(2):249-51. PubMed ID: 6876269
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Transrectal ultrasound to measure bladder volumes in men.
    Haylen BT; Parys BT; West CR
    J Urol; 1990 Apr; 143(4):687-9. PubMed ID: 2179580
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Residual urine determination by ultrasonic scanning.
    Pedersen JF; Bartrum RJ; Grytter C
    Am J Roentgenol Radium Ther Nucl Med; 1975 Oct; 125(2):474-8. PubMed ID: 54004
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Normal peak urinary flow rates obtained from small voided volumes can provide a reliable assessment of bladder function.
    Ryall RL; Marshall VR
    J Urol; 1982 Mar; 127(3):484-8. PubMed ID: 6460877
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Real-time ultrasound measurement of bladder volume: a comparative study of three methods.
    Hartnell GG; Kiely EA; Williams G; Gibson RN
    Br J Radiol; 1987 Nov; 60(719):1063-5. PubMed ID: 3318996
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of ultrasonic bladder volume measurement in children.
    Bis KG; Slovis TL
    Pediatr Radiol; 1990; 20(6):457-60. PubMed ID: 2202973
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Portable ultrasonography and bladder volume accuracy--a comparative study using three-dimensional ultrasonography.
    Ghani KR; Pilcher J; Rowland D; Patel U; Nassiri D; Anson K
    Urology; 2008 Jul; 72(1):24-8. PubMed ID: 18400276
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The accuracy of Bardscan: a new tool for the measurement of the bladder volume.
    Abdel-Fattah M; Barrington JW
    J Obstet Gynaecol; 2005 Feb; 25(2):186-8. PubMed ID: 15814403
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Ultrasound cystometry with reference to urinary bladder form and bladder filling].
    Knorr H; Strauss I; Seichert N
    Ultraschall Med; 1990 Jun; 11(3):150-4. PubMed ID: 2200118
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy of total bladder volume and residual urine measurements: comparison between real-time ultrasonography and catheterization.
    Mainprize TC; Drutz HP
    Am J Obstet Gynecol; 1989 Apr; 160(4):1013-6. PubMed ID: 2653036
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The accuracy of ultrasound in the measurement of changes in bladder volume.
    Poston GJ; Joseph AE; Riddle PR
    Br J Urol; 1983 Aug; 55(4):361-3. PubMed ID: 6883042
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Can we replace the catheter when evaluating urinary residuals?
    Araklitis G; Paganotto M; Hunter J; Thiagamoorthy G; Robinson D; Cardozo L
    Neurourol Urodyn; 2019 Apr; 38(4):1100-1105. PubMed ID: 30843290
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ultrasonographic evaluation of human fetal urinary flow rate: accuracy limits of bladder volume estimations.
    Hedriana HL; Moore TR
    Am J Obstet Gynecol; 1994 May; 170(5 Pt 1):1250-4. PubMed ID: 8178846
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Bladder volume correction factors measured with 3D ultrasound and BladderScan.
    Vinod NN; Nagle AS; Naimi HA; Kolli H; Sheen D; Nandanan N; Carucci LR; Speich JE; Klausner AP
    Can J Urol; 2019 Aug; 26(4):9829-9834. PubMed ID: 31469637
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The accuracy of a hand-held real time ultrasound scanner for estimating bladder volume.
    Ravichandran G; Fellows GJ
    Br J Urol; 1983 Feb; 55(1):25-7. PubMed ID: 6824861
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Clinical evaluation of patients with prostatic obstruction: correlation of flow rates with voided, residual or total bladder volume.
    Drach GW; Steinbronn DV
    J Urol; 1986 Apr; 135(4):737-40. PubMed ID: 2421016
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Transabdominal sonocystography: a novel technique to assess vesicourethral extravasation following radical prostatectomy.
    Lepor H; Kozirovsky M; Laze J; Telegrafi S
    J Urol; 2008 Dec; 180(6):2459-62. PubMed ID: 18930492
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Evaluation of bladder volume by ultrasonography].
    Robert Y; Chaillet D; Masquelier V; Lemaitre L
    J Radiol; 1995 Dec; 76(12):1087-91. PubMed ID: 8676296
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Does this man with lower urinary tract symptoms have bladder outlet obstruction?: The Rational Clinical Examination: a systematic review.
    D'Silva KA; Dahm P; Wong CL
    JAMA; 2014 Aug; 312(5):535-42. PubMed ID: 25096693
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Are portable bladder scanning and real-time ultrasound accurate measures of bladder volume in postnatal women?
    Mathew S; Horne AW; Murray LS; Tydeman G; McKinley CA
    J Obstet Gynaecol; 2007 Aug; 27(6):564-7. PubMed ID: 17896250
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.